A novel continuous capnodynamic method for cardiac output assessment in a porcine model of lung lavage. Issue 8 (4th June 2015)
- Record Type:
- Journal Article
- Title:
- A novel continuous capnodynamic method for cardiac output assessment in a porcine model of lung lavage. Issue 8 (4th June 2015)
- Main Title:
- A novel continuous capnodynamic method for cardiac output assessment in a porcine model of lung lavage
- Authors:
- Hällsjö Sander, C.
Hallbäck, M.
Suarez Sipmann, F.
Wallin, M.
Oldner, A.
Björne, H. - Abstract:
- <abstract abstract-type="main" id="aas12559-abs-0001"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="aas12559-sec-0001" sec-type="section"> <title>Background</title> <p>We have evaluated a new method for continuous monitoring of effective pulmonary blood flow (CO<sub>EPBF</sub>), i.e. cardiac output (CO) minus intra‐pulmonary shunt, during mechanical ventilation. The method has shown good trending ability during severe hemodynamic challenges in a porcine model with intact lungs. In this study, we further evaluate the CO<sub>EPBF</sub> method in a model of lung lavage.</p> </sec> <sec id="aas12559-sec-0002" sec-type="section"> <title>Methods</title> <p>CO<sub>EPBF</sub> was compared to a reference method for CO during hemodynamic and PEEP alterations, 5 and 12 cmH<sub>2</sub>O, before and after repeated lung lavages in 10 anaesthetised pigs. Bland–Altman, four‐quadrant and polar plot methodologies were used to determine agreement and trending ability.</p> </sec> <sec id="aas12559-sec-0003" sec-type="section"> <title>Results</title> <p>After lung lavage at PEEP 5 cmH<sub>2</sub>O, the ratio of arterial oxygen partial pressure related to inspired fraction of oxygen significantly decreased. The mean difference (limits of agreement) between methods changed from 0.2 (−1.1 to 1.5) to −0.9 (−3.6 to 1.9) l/min and percentage error increased from 34% to 70%. Trending ability remained good according to the four‐quadrant plot (concordance rate 94%), whereas mean angular<abstract abstract-type="main" id="aas12559-abs-0001"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="aas12559-sec-0001" sec-type="section"> <title>Background</title> <p>We have evaluated a new method for continuous monitoring of effective pulmonary blood flow (CO<sub>EPBF</sub>), i.e. cardiac output (CO) minus intra‐pulmonary shunt, during mechanical ventilation. The method has shown good trending ability during severe hemodynamic challenges in a porcine model with intact lungs. In this study, we further evaluate the CO<sub>EPBF</sub> method in a model of lung lavage.</p> </sec> <sec id="aas12559-sec-0002" sec-type="section"> <title>Methods</title> <p>CO<sub>EPBF</sub> was compared to a reference method for CO during hemodynamic and PEEP alterations, 5 and 12 cmH<sub>2</sub>O, before and after repeated lung lavages in 10 anaesthetised pigs. Bland–Altman, four‐quadrant and polar plot methodologies were used to determine agreement and trending ability.</p> </sec> <sec id="aas12559-sec-0003" sec-type="section"> <title>Results</title> <p>After lung lavage at PEEP 5 cmH<sub>2</sub>O, the ratio of arterial oxygen partial pressure related to inspired fraction of oxygen significantly decreased. The mean difference (limits of agreement) between methods changed from 0.2 (−1.1 to 1.5) to −0.9 (−3.6 to 1.9) l/min and percentage error increased from 34% to 70%. Trending ability remained good according to the four‐quadrant plot (concordance rate 94%), whereas mean angular bias increased from 4° to −16° when using the polar plot methodology.</p> </sec> <sec id="aas12559-sec-0004" sec-type="section"> <title>Conclusion</title> <p>Both agreement and precision of CO<sub>EPBF</sub> were impaired in relation to CO when the shunt fraction was increased after lavage at PEEP 5 cmH<sub>2</sub>O. However, trending ability remained good as assessed by the four‐quadrant plot, whereas the mean polar angle, calculated by the polar plot, was wide.</p> </sec> </abstract> … (more)
- Is Part Of:
- Acta anaesthesiologica scandinavica. Volume 59:Issue 8(2015:Sep.)
- Journal:
- Acta anaesthesiologica scandinavica
- Issue:
- Volume 59:Issue 8(2015:Sep.)
- Issue Display:
- Volume 59, Issue 8 (2015)
- Year:
- 2015
- Volume:
- 59
- Issue:
- 8
- Issue Sort Value:
- 2015-0059-0008-0000
- Page Start:
- 1022
- Page End:
- 1031
- Publication Date:
- 2015-06-04
- Subjects:
- Anesthesiology -- Periodicals
Critical care medicine -- Periodicals
617.9605 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1399-6576 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/aas.12559 ↗
- Languages:
- English
- ISSNs:
- 0001-5172
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0593.650000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 3710.xml