Determination of GDC‐0980 (apitolisib), a small molecule dual phosphatidylinositide 3‐kinase/mammalian target of rapamycin inhibitor in dog plasma by LC‐MS/MS to support a GLP toxicology study. (10th February 2015)
- Record Type:
- Journal Article
- Title:
- Determination of GDC‐0980 (apitolisib), a small molecule dual phosphatidylinositide 3‐kinase/mammalian target of rapamycin inhibitor in dog plasma by LC‐MS/MS to support a GLP toxicology study. (10th February 2015)
- Main Title:
- Determination of GDC‐0980 (apitolisib), a small molecule dual phosphatidylinositide 3‐kinase/mammalian target of rapamycin inhibitor in dog plasma by LC‐MS/MS to support a GLP toxicology study
- Authors:
- Ding, Xiao
Salphati, Laurent
Kim, Amy
Morinello, Eric
Wong, Lisa
Pang, Jodie
Percey, Shaundel
Meng, Min
Reuschel, Scott
Dean, Brian - Abstract:
- <abstract abstract-type="main"> <title>Abstract</title> <p>An LC‐MS/MS method for the determination of GDC‐0980 (apitolisib) concentrations in dog plasma has been developed and validated for the first time to support pre‐clinical drug development. Following protein precipitation with acetonitrile, the resulting samples were analyzed using reverse‐phase chromatography on a Metasil AQ column. The mass analysis was performed on a triple quadruple mass spectrometer coupled with an electrospray interface in positive ionization mode. The selected reaction monitoring transitions monitored were <italic>m</italic>/<italic>z</italic> 499.3 → 341.1 for GDC‐0980 and <italic>m</italic>/<italic>z</italic> 507.3 → 341.1 for IS. The method was validated over the calibration curve range 0.250–250 ng/mL with linear regression and 1/<italic>x</italic><sup>2</sup> weighting. Relative standard deviation (RSD) ranged from 0.0 to 10.9% and accuracy ranged from 93.4 to 113.6% of nominal. Stable‐labeled internal standard GDC‐0980‐d<sub>8</sub> was used to minimize matrix effects. This assay was used for the measurement of GDC‐0980 dog plasma concentrations to determine toxicokinetic parameters after oral administration of GDC‐0980 (0.03, 0.1 and 0.3 mg/kg) to beagle dogs in a GLP toxicology study. Peak concentration ranged from 3.23 to 84.9 ng/mL. GDC‐0980 was rapidly absorbed with a mean time to peak concentration ranging from 1.3 to 2.4 h. Mean area under the concentration–time curve from 0 to<abstract abstract-type="main"> <title>Abstract</title> <p>An LC‐MS/MS method for the determination of GDC‐0980 (apitolisib) concentrations in dog plasma has been developed and validated for the first time to support pre‐clinical drug development. Following protein precipitation with acetonitrile, the resulting samples were analyzed using reverse‐phase chromatography on a Metasil AQ column. The mass analysis was performed on a triple quadruple mass spectrometer coupled with an electrospray interface in positive ionization mode. The selected reaction monitoring transitions monitored were <italic>m</italic>/<italic>z</italic> 499.3 → 341.1 for GDC‐0980 and <italic>m</italic>/<italic>z</italic> 507.3 → 341.1 for IS. The method was validated over the calibration curve range 0.250–250 ng/mL with linear regression and 1/<italic>x</italic><sup>2</sup> weighting. Relative standard deviation (RSD) ranged from 0.0 to 10.9% and accuracy ranged from 93.4 to 113.6% of nominal. Stable‐labeled internal standard GDC‐0980‐d<sub>8</sub> was used to minimize matrix effects. This assay was used for the measurement of GDC‐0980 dog plasma concentrations to determine toxicokinetic parameters after oral administration of GDC‐0980 (0.03, 0.1 and 0.3 mg/kg) to beagle dogs in a GLP toxicology study. Peak concentration ranged from 3.23 to 84.9 ng/mL. GDC‐0980 was rapidly absorbed with a mean time to peak concentration ranging from 1.3 to 2.4 h. Mean area under the concentration–time curve from 0 to 24 hours ranged from 54.4 to 542 ng h/mL. Copyright © 2015 John Wiley &amp; Sons, Ltd.</p> </abstract> … (more)
- Is Part Of:
- Biomedical chromatography. Volume 29:Number 8(2015:Aug.)
- Journal:
- Biomedical chromatography
- Issue:
- Volume 29:Number 8(2015:Aug.)
- Issue Display:
- Volume 29, Issue 8 (2015)
- Year:
- 2015
- Volume:
- 29
- Issue:
- 8
- Issue Sort Value:
- 2015-0029-0008-0000
- Page Start:
- 1274
- Page End:
- 1279
- Publication Date:
- 2015-02-10
- Subjects:
- Chromatographic analysis -- Periodicals
Biology -- Periodicals
Medicine -- Periodicals
Biology -- Periodicals
Chromatography -- methods -- Periodicals
Medicine -- Periodicals
543.089 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1002/bmc.3417 ↗
- Languages:
- English
- ISSNs:
- 0269-3879
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 2087.758000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 3630.xml