What is the underlying mechanism for the failure mode observed in the proximal femoral locking compression plate? A biomechanical study. Issue 8 (August 2015)
- Record Type:
- Journal Article
- Title:
- What is the underlying mechanism for the failure mode observed in the proximal femoral locking compression plate? A biomechanical study. Issue 8 (August 2015)
- Main Title:
- What is the underlying mechanism for the failure mode observed in the proximal femoral locking compression plate? A biomechanical study
- Authors:
- Schneider, Kerstin
Oh, Jong-Keon
Zderic, Ivan
Stoffel, Karl
Richards, R. Geoff
Wolf, Stefan
Gueorguiev, Boyko
Nork, Sean E. - Abstract:
- <abstract abstract-type="author" id="abs0005"> <title id="sect0005">Abstract</title> <sec> <title id="sect0010">Purpose</title> <p id="spar0005">Recently, several cases of clinical failure have been reported for the Proximal Femoral Locking Compression Plate (PF-LCP). The current study was designed to explore biomechanically the underlying mechanism and to determine whether the observed failure was due to technical error on insertion or to implant design.</p> </sec> <sec> <title id="sect0015">Methods</title> <p id="spar0010">A foam block model simulating an unstable intertrochanteric fracture was created for 3 study groups with 6 specimens each. Group C was correctly instrumented according to the manufacturer's guidelines. In Group P and Group A, the first or second proximal screw was placed with a posterior or anterior off-axis orientation by 2° measured in the transversal plane, respectively. Each construct was cyclically tested until failure using a test setup and protocol simulating complex axial and torsional loading. Radiographs were taken prior to and after the tests. Force, number of cycles to failure and failure mode were compared.</p> </sec> <sec> <title id="sect0020">Results</title> <p id="spar0015">A screw deviation of 2° from the nominal axis led to significantly earlier construct failure in Group P and Group A in comparison to Group C. The failure mode was characterised by loosening of the off-axis screw due to disengagement with the plate, resulting in loss of<abstract abstract-type="author" id="abs0005"> <title id="sect0005">Abstract</title> <sec> <title id="sect0010">Purpose</title> <p id="spar0005">Recently, several cases of clinical failure have been reported for the Proximal Femoral Locking Compression Plate (PF-LCP). The current study was designed to explore biomechanically the underlying mechanism and to determine whether the observed failure was due to technical error on insertion or to implant design.</p> </sec> <sec> <title id="sect0015">Methods</title> <p id="spar0010">A foam block model simulating an unstable intertrochanteric fracture was created for 3 study groups with 6 specimens each. Group C was correctly instrumented according to the manufacturer's guidelines. In Group P and Group A, the first or second proximal screw was placed with a posterior or anterior off-axis orientation by 2° measured in the transversal plane, respectively. Each construct was cyclically tested until failure using a test setup and protocol simulating complex axial and torsional loading. Radiographs were taken prior to and after the tests. Force, number of cycles to failure and failure mode were compared.</p> </sec> <sec> <title id="sect0020">Results</title> <p id="spar0015">A screw deviation of 2° from the nominal axis led to significantly earlier construct failure in Group P and Group A in comparison to Group C. The failure mode was characterised by loosening of the off-axis screw due to disengagement with the plate, resulting in loss of construct stiffness and varus collapse of the fracture.</p> </sec> <sec> <title id="sect0025">Conclusions</title> <p id="spar0020">In our biomechanical test setup, the clinical failure modes observed with the PF-LCP were reproducible. A screw deviation of 2° from the nominal axis consistently led to the failure. This highlights how crucial is the accurate placement of locking screws in the proximal femur.</p> </sec> </abstract> … (more)
- Is Part Of:
- Injury. Volume 46:Issue 8(2015)
- Journal:
- Injury
- Issue:
- Volume 46:Issue 8(2015)
- Issue Display:
- Volume 46, Issue 8 (2015)
- Year:
- 2015
- Volume:
- 46
- Issue:
- 8
- Issue Sort Value:
- 2015-0046-0008-0000
- Page Start:
- 1483
- Page End:
- 1490
- Publication Date:
- 2015-08
- Subjects:
- Wounds and injuries -- Surgery -- Periodicals
Accidents -- Periodicals
Wounds and Injuries -- surgery -- Periodicals
Lésions et blessures -- Chirurgie -- Périodiques
Electronic journals
Electronic journals
617.1 - Journal URLs:
- http://www.sciencedirect.com/science/journal/00201383 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/00201383 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/00201383 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.injury.2015.05.034 ↗
- Languages:
- English
- ISSNs:
- 0020-1383
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4514.400000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 3166.xml