Quantitation of ortho‐cresyl phosphate adducts to butyrylcholinesterase in human serum by immunomagnetic‐UHPLC‐MS/MS. (13th March 2015)
- Record Type:
- Journal Article
- Title:
- Quantitation of ortho‐cresyl phosphate adducts to butyrylcholinesterase in human serum by immunomagnetic‐UHPLC‐MS/MS. (13th March 2015)
- Main Title:
- Quantitation of ortho‐cresyl phosphate adducts to butyrylcholinesterase in human serum by immunomagnetic‐UHPLC‐MS/MS
- Authors:
- Johnson, Darryl
Carter, Melissa D.
Crow, Brian S.
Isenberg, Samantha L.
Graham, Leigh Ann
Erol, H. Akin
Watson, Caroline M.
Pantazides, Brooke G.
van der Schans, Marcel J.
Langenberg, Jan P.
Noort, Daan
Blake, Thomas A.
Thomas, Jerry D.
Johnson, Rudolph C. - Abstract:
- <abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <p>Tri‐ortho‐cresyl phosphate (ToCP) is an anti‐wear, flame retardant additive used in industrial lubricants, hydraulic fluids and gasoline. The neurotoxic effects of ToCP arise from the liver‐activated metabolite 2‐(o‐cresyl)‐4H‐1, 3, 2‐benzodioxaphosphoran‐2‐one (cresyl saligenin phosphate or CBDP), which inhibits esterase enzymes including butyrylcholinesterase (BChE). Following BChE adduction, CBDP undergoes hydrolysis to form the aged adduct ortho‐cresyl phosphoserine (oCP‐BChE), thus providing a biomarker of CBDP exposure. Previous studies have identified ToCP in aircraft cabin and cockpit air, but assessing human exposure has been hampered by the lack of a laboratory assay to confirm exposure. This work presents the development of an immunomagnetic‐UHPLC‐MS/MS method for the quantitation of unadducted BChE and the long‐term CBDP biomarker, oCP‐BChE, in human serum. The method has a reportable range from 2.0 ng/ml to 150 ng/ml, which is consistent with the sensitivity of methods used to detect organophosphorus nerve agent protein adducts. The assay demonstrated high intraday and interday accuracy (≥85%) and precision (RSD ≤ 15%) across the calibration range. The method was developed for future analyses of potential human exposure to CBDP. Analysis of human serum inhibited <italic>in vitro</italic> with CBDP demonstrated that the oCP‐BChE adduct was stable for at least 72 h at 4, 22<abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <p>Tri‐ortho‐cresyl phosphate (ToCP) is an anti‐wear, flame retardant additive used in industrial lubricants, hydraulic fluids and gasoline. The neurotoxic effects of ToCP arise from the liver‐activated metabolite 2‐(o‐cresyl)‐4H‐1, 3, 2‐benzodioxaphosphoran‐2‐one (cresyl saligenin phosphate or CBDP), which inhibits esterase enzymes including butyrylcholinesterase (BChE). Following BChE adduction, CBDP undergoes hydrolysis to form the aged adduct ortho‐cresyl phosphoserine (oCP‐BChE), thus providing a biomarker of CBDP exposure. Previous studies have identified ToCP in aircraft cabin and cockpit air, but assessing human exposure has been hampered by the lack of a laboratory assay to confirm exposure. This work presents the development of an immunomagnetic‐UHPLC‐MS/MS method for the quantitation of unadducted BChE and the long‐term CBDP biomarker, oCP‐BChE, in human serum. The method has a reportable range from 2.0 ng/ml to 150 ng/ml, which is consistent with the sensitivity of methods used to detect organophosphorus nerve agent protein adducts. The assay demonstrated high intraday and interday accuracy (≥85%) and precision (RSD ≤ 15%) across the calibration range. The method was developed for future analyses of potential human exposure to CBDP. Analysis of human serum inhibited <italic>in vitro</italic> with CBDP demonstrated that the oCP‐BChE adduct was stable for at least 72 h at 4, 22 and 37 °C. Compared to a previously reported assay, this method requires 75% less sample volume, reduces analysis time by a factor of 20 and demonstrates a threefold improvement in sensitivity. Published 2015. This article is a U.S. Government work and is in the public domain in the USA.</p> </abstract> … (more)
- Is Part Of:
- Journal of mass spectrometry. Volume 50:Number 4(2015:Apr.)
- Journal:
- Journal of mass spectrometry
- Issue:
- Volume 50:Number 4(2015:Apr.)
- Issue Display:
- Volume 50, Issue 4 (2015)
- Year:
- 2015
- Volume:
- 50
- Issue:
- 4
- Issue Sort Value:
- 2015-0050-0004-0000
- Page Start:
- 683
- Page End:
- 692
- Publication Date:
- 2015-03-13
- Subjects:
- Mass spectrometry -- Periodicals
543.65 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1002/jms.3576 ↗
- Languages:
- English
- ISSNs:
- 1076-5174
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5012.179500
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 3509.xml