A comparative finite elemental analysis of glass abutment supported and unsupported cantilever fixed partial denture. Issue 5 (May 2015)
- Record Type:
- Journal Article
- Title:
- A comparative finite elemental analysis of glass abutment supported and unsupported cantilever fixed partial denture. Issue 5 (May 2015)
- Main Title:
- A comparative finite elemental analysis of glass abutment supported and unsupported cantilever fixed partial denture
- Authors:
- Ramakrishaniah, Ravikumar
Al kheraif, Abdulaziz A.
Elsharawy, Mohamed A.
Alsaleh, Ayman K.
Ismail Mohamed, Karem M.
Rehman, Ihtesham Ur - Abstract:
- <abstract abstract-type="author" id="abs0005"> <title id="sect0005">Abstract</title> <sec> <title id="sect0010">Objective</title> <p id="spar0005">The purpose of this study was to investigate and compare the load distribution and displacement of cantilever prostheses with and without glass abutment by three dimensional finite element analysis. Micro-computed tomography was used to study the relationship between the glass abutment and the ridge.</p> </sec> <sec> <title id="sect0015">Methods</title> <p id="spar0010">The external surface of the maxilla was scanned, and a simplified finite element model was constructed. The ZX-27 glass abutment and the maxillary first and second premolars were created and modified. The solid model of the three-unit cantilever fixed partial denture was scanned, and the fitting surface was modified with reference to the created abutments using the 3D CAD system. The finite element analysis was completed in ANSYS. The fit and total gap volume between the glass abutment and dental model were determined by Skyscan 1173 high-energy spiral micro-CT scan.</p> </sec> <sec> <title id="sect0020">Results</title> <p id="spar0015">The results of the finite element analysis in this study showed that the cantilever prosthesis supported by the glass abutment demonstrated significantly less stress on the terminal abutment and overall deformation of the prosthesis under vertical and oblique load. Micro-computed tomography determined a gap volume of<abstract abstract-type="author" id="abs0005"> <title id="sect0005">Abstract</title> <sec> <title id="sect0010">Objective</title> <p id="spar0005">The purpose of this study was to investigate and compare the load distribution and displacement of cantilever prostheses with and without glass abutment by three dimensional finite element analysis. Micro-computed tomography was used to study the relationship between the glass abutment and the ridge.</p> </sec> <sec> <title id="sect0015">Methods</title> <p id="spar0010">The external surface of the maxilla was scanned, and a simplified finite element model was constructed. The ZX-27 glass abutment and the maxillary first and second premolars were created and modified. The solid model of the three-unit cantilever fixed partial denture was scanned, and the fitting surface was modified with reference to the created abutments using the 3D CAD system. The finite element analysis was completed in ANSYS. The fit and total gap volume between the glass abutment and dental model were determined by Skyscan 1173 high-energy spiral micro-CT scan.</p> </sec> <sec> <title id="sect0020">Results</title> <p id="spar0015">The results of the finite element analysis in this study showed that the cantilever prosthesis supported by the glass abutment demonstrated significantly less stress on the terminal abutment and overall deformation of the prosthesis under vertical and oblique load. Micro-computed tomography determined a gap volume of 6.74162 mm<sup>3</sup>.</p> </sec> <sec> <title id="sect0025">Significance</title> <p id="spar0020">By contacting the mucosa, glass abutments transfer some amount of masticatory load to the residual alveolar ridge, thereby preventing damage to the periodontal microstructures of the terminal abutment. The passive contact of the glass abutment with the mucosa not only preserves the health of the mucosa covering the ridge but also permits easy cleaning. It is possible to increase the success rate of cantilever FPDs by supporting the cantilevered pontic with glass abutments.</p> </sec> </abstract> … (more)
- Is Part Of:
- Dental materials. Volume 31:Issue 5(2015)
- Journal:
- Dental materials
- Issue:
- Volume 31:Issue 5(2015)
- Issue Display:
- Volume 31, Issue 5 (2015)
- Year:
- 2015
- Volume:
- 31
- Issue:
- 5
- Issue Sort Value:
- 2015-0031-0005-0000
- Page Start:
- 514
- Page End:
- 521
- Publication Date:
- 2015-05
- Subjects:
- Dentistry -- Periodicals
Dental materials -- Periodicals
617.695 - Journal URLs:
- http://www.elsevier.com/journals ↗
http://www.sciencedirect.com/science/journal/01095641/ ↗ - DOI:
- 10.1016/j.dental.2015.02.003 ↗
- Languages:
- English
- ISSNs:
- 0109-5641
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3553.365800
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 4004.xml