Evaluation of blood glucose fluctuation in Japanese patients with type 1 diabetes mellitus by self-monitoring of blood glucose and continuous glucose monitoring. Issue 2 (May 2015)
- Record Type:
- Journal Article
- Title:
- Evaluation of blood glucose fluctuation in Japanese patients with type 1 diabetes mellitus by self-monitoring of blood glucose and continuous glucose monitoring. Issue 2 (May 2015)
- Main Title:
- Evaluation of blood glucose fluctuation in Japanese patients with type 1 diabetes mellitus by self-monitoring of blood glucose and continuous glucose monitoring
- Authors:
- Kusunoki, Yoshiki
Katsuno, Tomoyuki
Nakae, Rie
Watanabe, Kahori
Akagami, Takafumi
Ochi, Fumihiro
Tokuda, Masaru
Murai, Kazuki
Miuchi, Masayuki
Miyagawa, Jun-ichiro
Namba, Mitsuyoshi - Abstract:
- <abstract abstract-type="author" id="abs0005"> <title id="sect0005">Abstract</title> <sec> <title id="sect0010">Aims</title> <p id="spar0005">Accurate assessment of blood glucose fluctuation is essential for managing blood glucose control while avoiding hypoglycemia in patients with diabetes mellitus. In this study, blood glucose was measured by continuous glucose monitoring (CGM) in patients with type 1 diabetes mellitus (T1DM) whom self-monitoring of blood glucose (SMBG) was carried out three or more times per day, and evaluation was performed using blood glucose fluctuation parameters obtained by CGM and SMBG.</p> </sec> <sec> <title id="sect0015">Methods</title> <p id="spar0010">Twenty-nine insulin-depleted patients with T1DM were enrolled. Their blood glucose fluctuations were measured at the same time by SMBG and CGM, and the correlations were evaluated.</p> </sec> <sec> <title id="sect0020">Results</title> <p id="spar0015">Correlations were found between the following values obtained by SMBG and CGM: mean and standard deviation of blood glucose levels, average daily risk range, Morbus value and high-blood-glucose index. The hypoglycemia duration and the nocturnal hypoglycemia duration showed no correlation with any of the blood glucose fluctuation parameters obtained by SMBG.</p> </sec> <sec> <title id="sect0025">Conclusions</title> <p id="spar0020">The findings suggest that routine SMBG and glycated hemoglobin (HbA1c) measurement are sufficient for evaluation of<abstract abstract-type="author" id="abs0005"> <title id="sect0005">Abstract</title> <sec> <title id="sect0010">Aims</title> <p id="spar0005">Accurate assessment of blood glucose fluctuation is essential for managing blood glucose control while avoiding hypoglycemia in patients with diabetes mellitus. In this study, blood glucose was measured by continuous glucose monitoring (CGM) in patients with type 1 diabetes mellitus (T1DM) whom self-monitoring of blood glucose (SMBG) was carried out three or more times per day, and evaluation was performed using blood glucose fluctuation parameters obtained by CGM and SMBG.</p> </sec> <sec> <title id="sect0015">Methods</title> <p id="spar0010">Twenty-nine insulin-depleted patients with T1DM were enrolled. Their blood glucose fluctuations were measured at the same time by SMBG and CGM, and the correlations were evaluated.</p> </sec> <sec> <title id="sect0020">Results</title> <p id="spar0015">Correlations were found between the following values obtained by SMBG and CGM: mean and standard deviation of blood glucose levels, average daily risk range, Morbus value and high-blood-glucose index. The hypoglycemia duration and the nocturnal hypoglycemia duration showed no correlation with any of the blood glucose fluctuation parameters obtained by SMBG.</p> </sec> <sec> <title id="sect0025">Conclusions</title> <p id="spar0020">The findings suggest that routine SMBG and glycated hemoglobin (HbA1c) measurement are sufficient for evaluation of hyperglycemia in T1DM. On the other hand, blood glucose fluctuation parameters obtained by SMBG and HbA1c have been shown to have no correlations with either hypoglycemia duration or nocturnal hypoglycemia duration.</p> </sec> </abstract> … (more)
- Is Part Of:
- Diabetes research and clinical practice. Volume 108:Issue 2(2015)
- Journal:
- Diabetes research and clinical practice
- Issue:
- Volume 108:Issue 2(2015)
- Issue Display:
- Volume 108, Issue 2 (2015)
- Year:
- 2015
- Volume:
- 108
- Issue:
- 2
- Issue Sort Value:
- 2015-0108-0002-0000
- Page Start:
- 342
- Page End:
- 349
- Publication Date:
- 2015-05
- Subjects:
- Diabetes -- Periodicals
Diabetes Mellitus -- Periodicals
616.462 - Journal URLs:
- http://www.sciencedirect.com/science/journal/01688227 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/01688227 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/01688227 ↗
http://www.sciencedirect.com/science/journal/01688227 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.diabres.2015.01.040 ↗
- Languages:
- English
- ISSNs:
- 0168-8227
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3579.603700
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 3273.xml