Development of a new suturing technique for tendon graft preparation: An animal cadaver study. Issue 4 (May 2015)
- Record Type:
- Journal Article
- Title:
- Development of a new suturing technique for tendon graft preparation: An animal cadaver study. Issue 4 (May 2015)
- Main Title:
- Development of a new suturing technique for tendon graft preparation: An animal cadaver study
- Authors:
- Postl, L.K.
Kirchhoff, C.
Hupertz, V.
Plitz, W.
Schmitt-Sody, M. - Abstract:
- <abstract abstract-type="author" id="ab0005"> <title id="st0005">Abstract</title> <sec> <title id="st0010">Background</title> <p id="sp0005">This study should analyze ten different suturing techniques for tendon graft preparation to allow the development of an entirely new suturing technique.</p> </sec> <sec> <title id="st0015">Methods</title> <p id="sp0010">Extensor tendon grafts of fattening bulls' forelegs were sutured with Ethibond Excel size three (six metric) fibers (Ethicon, Somerville, New York, USA). The tendon/suture complexes were biomechanically tested with a hydraulic testing machine applying traction according to a standardized protocol. The testing was observed to find out why the failure at the maximum traction load occurred. The mean values for the maximum tension and extension stiffness were recorded for each suturing technique.</p> </sec> <sec> <title id="st0100">Findings</title> <p id="sp0020">An entirely new suturing technique was developed based on the observations and biomechanical results. The newly developed suture was also tested and provided a higher traction stability than the other ten techniques that had been evaluated. Compared to the other ten techniques the new technique was ranked 3rd in terms of extension stiffness and reached 10.3 N/mm.</p> </sec> <sec> <title id="st0105">Interpretation</title> <p id="sp0030">The new technique evolved in the course of this study provided promising results. Therefore this study provides initial evidence<abstract abstract-type="author" id="ab0005"> <title id="st0005">Abstract</title> <sec> <title id="st0010">Background</title> <p id="sp0005">This study should analyze ten different suturing techniques for tendon graft preparation to allow the development of an entirely new suturing technique.</p> </sec> <sec> <title id="st0015">Methods</title> <p id="sp0010">Extensor tendon grafts of fattening bulls' forelegs were sutured with Ethibond Excel size three (six metric) fibers (Ethicon, Somerville, New York, USA). The tendon/suture complexes were biomechanically tested with a hydraulic testing machine applying traction according to a standardized protocol. The testing was observed to find out why the failure at the maximum traction load occurred. The mean values for the maximum tension and extension stiffness were recorded for each suturing technique.</p> </sec> <sec> <title id="st0100">Findings</title> <p id="sp0020">An entirely new suturing technique was developed based on the observations and biomechanical results. The newly developed suture was also tested and provided a higher traction stability than the other ten techniques that had been evaluated. Compared to the other ten techniques the new technique was ranked 3rd in terms of extension stiffness and reached 10.3 N/mm.</p> </sec> <sec> <title id="st0105">Interpretation</title> <p id="sp0030">The new technique evolved in the course of this study provided promising results. Therefore this study provides initial evidence that this technique could be useful in clinical routine.</p> </sec> </abstract> … (more)
- Is Part Of:
- Clinical biomechanics. Volume 30:Issue 4(2015)
- Journal:
- Clinical biomechanics
- Issue:
- Volume 30:Issue 4(2015)
- Issue Display:
- Volume 30, Issue 4 (2015)
- Year:
- 2015
- Volume:
- 30
- Issue:
- 4
- Issue Sort Value:
- 2015-0030-0004-0000
- Page Start:
- 377
- Page End:
- 382
- Publication Date:
- 2015-05
- Subjects:
- Biomechanics -- Periodicals
Osteopathic medicine -- Periodicals
Biomechanics -- Periodicals
Osteopathic Medicine -- Periodicals
612.76 - Journal URLs:
- http://www.sciencedirect.com/science/journal/02680033 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.clinbiomech.2015.02.009 ↗
- Languages:
- English
- ISSNs:
- 0268-0033
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.262800
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 4346.xml