AP versus PA positioning in lumbar spine computed radiography: Image quality and individual organ doses. Issue 2 (May 2015)
- Record Type:
- Journal Article
- Title:
- AP versus PA positioning in lumbar spine computed radiography: Image quality and individual organ doses. Issue 2 (May 2015)
- Main Title:
- AP versus PA positioning in lumbar spine computed radiography: Image quality and individual organ doses
- Authors:
- Davey, Enda
England, Andrew - Abstract:
- <abstract xml:lang="en" abstract-type="author" id="abs0010"> <title id="sectitle0010">Abstract</title> <sec> <title id="sectitle0015">Purpose</title> <p id="abspara0010">Radiological imaging examinations must be optimised in order to ensure that the radiation dose is kept as low as reasonably possible (ALARP). The aim of this study was to compare anteroposterior (AP) and posteroanterior (PA) projections of the lumbar spine, at various kVp increments, in order to establish optimum parameters.</p> </sec> <sec> <title id="sectitle0020">Methods</title> <p id="abspara0015">An anthropomorphic phantom was imaged in both the AP/PA projections and at various kVp increments. Acquisitions were undertaken using a Wolverson Acroma X-ray unit and processed using an Agfa computed radiography (CR) unit. The entrance surface dose was recorded and converted to effective and organ doses using PCXMC 2.0 software. Five observers were then asked to evaluate the images, using a two-alternative force choice (2AFC) approach and a scale based on EC guidelines.</p> </sec> <sec> <title id="sectitle0025">Results</title> <p id="abspara0020">The PA projection lowered the mean effective dose by 19.8% and also the mean absorbed dose to the stomach (70.4%), colon (61.1%), remainder tissues (33.2%), ovaries (7.3%) and testes (15.9%). However, this was at the expense of slightly inferior image quality, not statistically significant. For AP projections, a higher kVp is a further option for dose reduction.</p><abstract xml:lang="en" abstract-type="author" id="abs0010"> <title id="sectitle0010">Abstract</title> <sec> <title id="sectitle0015">Purpose</title> <p id="abspara0010">Radiological imaging examinations must be optimised in order to ensure that the radiation dose is kept as low as reasonably possible (ALARP). The aim of this study was to compare anteroposterior (AP) and posteroanterior (PA) projections of the lumbar spine, at various kVp increments, in order to establish optimum parameters.</p> </sec> <sec> <title id="sectitle0020">Methods</title> <p id="abspara0015">An anthropomorphic phantom was imaged in both the AP/PA projections and at various kVp increments. Acquisitions were undertaken using a Wolverson Acroma X-ray unit and processed using an Agfa computed radiography (CR) unit. The entrance surface dose was recorded and converted to effective and organ doses using PCXMC 2.0 software. Five observers were then asked to evaluate the images, using a two-alternative force choice (2AFC) approach and a scale based on EC guidelines.</p> </sec> <sec> <title id="sectitle0025">Results</title> <p id="abspara0020">The PA projection lowered the mean effective dose by 19.8% and also the mean absorbed dose to the stomach (70.4%), colon (61.1%), remainder tissues (33.2%), ovaries (7.3%) and testes (15.9%). However, this was at the expense of slightly inferior image quality, not statistically significant. For AP projections, a higher kVp is a further option for dose reduction.</p> </sec> <sec> <title id="sectitle0030">Conclusion</title> <p id="abspara0025">Dose optimisation requires the production of an image that is acceptable for the purpose intended. Based on ALARP, and when taking into consideration the dose reductions in this study, it may now be time to routinely use PA projections when imaging the lumbar spine. The use of a higher kVp should also be considered as an option but would be more useful for AP projections.</p> </sec> </abstract> … (more)
- Is Part Of:
- Radiography. Volume 21:Issue 2(2015)
- Journal:
- Radiography
- Issue:
- Volume 21:Issue 2(2015)
- Issue Display:
- Volume 21, Issue 2 (2015)
- Year:
- 2015
- Volume:
- 21
- Issue:
- 2
- Issue Sort Value:
- 2015-0021-0002-0000
- Page Start:
- 188
- Page End:
- 196
- Publication Date:
- 2015-05
- Subjects:
- Diagnostic imaging -- Periodicals
Radiotherapy -- Periodicals
Cancer -- Radiotherapy -- Periodicals
Diagnostic Imaging -- Periodicals
Neoplasms -- Periodicals
Radiotherapy -- Periodicals
Imagerie pour le diagnostic -- Périodiques
Radiothérapie -- Périodiques
Cancer -- Radiothérapie -- Périodiques
Electronic journals
616.0757 - Journal URLs:
- http://www.sciencedirect.com/science/journal/10788174 ↗
http://www.radiographyonline.com/ ↗
http://www.harcourt-international.com/journals ↗
http://www.idealibrary.com/links/toc/radi/ ↗
http://www.clinicalkey.com/dura/browse/journalIssue/10788174 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/10788174 ↗
http://www.elsevier.com/journals ↗
http://www.journals.elsevier.com/radiography/ ↗ - DOI:
- 10.1016/j.radi.2014.11.003 ↗
- Languages:
- English
- ISSNs:
- 1078-8174
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7237.001000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 3009.xml