Comparison of the strain field of abdominal aortic aneurysm measured by magnetic resonance imaging and stereovision: A feasibility study for prediction of the risk of rupture of aortic abdominal aneurysm. Issue 6 (13th April 2015)
- Record Type:
- Journal Article
- Title:
- Comparison of the strain field of abdominal aortic aneurysm measured by magnetic resonance imaging and stereovision: A feasibility study for prediction of the risk of rupture of aortic abdominal aneurysm. Issue 6 (13th April 2015)
- Main Title:
- Comparison of the strain field of abdominal aortic aneurysm measured by magnetic resonance imaging and stereovision: A feasibility study for prediction of the risk of rupture of aortic abdominal aneurysm
- Authors:
- Wang, Yufei
Joannic, David
Delassus, Patrick
Lalande, Alain
Juillion, Patrick
Fontaine, Jean-François - Abstract:
- <abstract abstract-type="author" id="ab0005"> <title id="sect0005">Abstract</title> <sec> <p id="sp0055">The prediction of the risk of rupture of abdominal aortic aneurysm (AAA) is a complex problem. Currently the criteria to predict rupture of abdominal aortic aneurysms are aneurysm diameter and growth rates. It is generally believed that study of the wall strain distribution could be helpful to find a better decision criterion for surgery of aortic aneurysms before their rupture. The wall strain distribution depends on many biological and biomechanical factors such as elastic properties of the aorta, turbulent blood flow, anatomy of the aorta, presence of thrombus or not and so on. Recently, numerical simulations to estimate rupture-potential have received many attentions. However, none of the medical imaging tools for screening and monitoring of AAAs were studied in terms of mechanical behavior and experimentally to demonstrate their capability to measure relevant variables. The aim of this study was to develop a metrological approach for deployment testing of the ability of techniques for measuring local in-vitro deformations based on comparison of stereovision and MRI. In this paper, we present the implementation approach and results of the study based on cylindrical phantoms with or without AAA representing, respectively, healthy and unhealthy artery. Through this study, an experimental device was developed for the behavior study of AAA during a cardiac cycle. The<abstract abstract-type="author" id="ab0005"> <title id="sect0005">Abstract</title> <sec> <p id="sp0055">The prediction of the risk of rupture of abdominal aortic aneurysm (AAA) is a complex problem. Currently the criteria to predict rupture of abdominal aortic aneurysms are aneurysm diameter and growth rates. It is generally believed that study of the wall strain distribution could be helpful to find a better decision criterion for surgery of aortic aneurysms before their rupture. The wall strain distribution depends on many biological and biomechanical factors such as elastic properties of the aorta, turbulent blood flow, anatomy of the aorta, presence of thrombus or not and so on. Recently, numerical simulations to estimate rupture-potential have received many attentions. However, none of the medical imaging tools for screening and monitoring of AAAs were studied in terms of mechanical behavior and experimentally to demonstrate their capability to measure relevant variables. The aim of this study was to develop a metrological approach for deployment testing of the ability of techniques for measuring local in-vitro deformations based on comparison of stereovision and MRI. In this paper, we present the implementation approach and results of the study based on cylindrical phantoms with or without AAA representing, respectively, healthy and unhealthy artery. Through this study, an experimental device was developed for the behavior study of AAA during a cardiac cycle. The results show that the stereovision techniques used in laboratory is well suited and is qualitatively and quantitatively equivalent with MRI measurements.</p> </sec> </abstract> … (more)
- Is Part Of:
- Journal of biomechanics. Volume 48:Issue 6(2015)
- Journal:
- Journal of biomechanics
- Issue:
- Volume 48:Issue 6(2015)
- Issue Display:
- Volume 48, Issue 6 (2015)
- Year:
- 2015
- Volume:
- 48
- Issue:
- 6
- Issue Sort Value:
- 2015-0048-0006-0000
- Page Start:
- 1158
- Page End:
- 1164
- Publication Date:
- 2015-04-13
- Subjects:
- Animal mechanics -- Periodicals
Biomechanics -- Periodicals
Biomechanics -- Periodicals
Mécanique animale -- Périodiques
Biomécanique -- Périodiques
Electronic journals
571.4305 - Journal URLs:
- http://www.sciencedirect.com/science/journal/00219290 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/00219290 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/00219290 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jbiomech.2015.01.017 ↗
- Languages:
- English
- ISSNs:
- 0021-9290
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4953.600000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 4324.xml