Phase-Sensitive Dual-Inversion Recovery for Accelerated Carotid Vessel Wall Imaging. Issue 3 (March 2015)
- Record Type:
- Journal Article
- Title:
- Phase-Sensitive Dual-Inversion Recovery for Accelerated Carotid Vessel Wall Imaging. Issue 3 (March 2015)
- Main Title:
- Phase-Sensitive Dual-Inversion Recovery for Accelerated Carotid Vessel Wall Imaging
- Authors:
- Bonanno, Gabriele
Brotman, David
Stuber, Matthias - Abstract:
- <abstract> <title> <x xml:space="preserve">Abstract</x> </title> <sec> <title>Objectives</title> <p>Dual-inversion recovery (DIR) is widely used for magnetic resonance vessel wall imaging. However, optimal contrast may be difficult to obtain and is subject to RR variability. Furthermore, DIR imaging is time-inefficient and multislice acquisitions may lead to prolonged scanning times. Therefore, an extension of phase-sensitive (PS) DIR is proposed for carotid vessel wall imaging.</p> </sec> <sec> <title>Methods</title> <p>The statistical distribution of the phase signal after DIR is probed to segment carotid lumens and suppress their residual blood signal. The proposed PS-DIR technique was characterized over a broad range of inversion times. Multislice imaging was then implemented by interleaving the acquisition of 3 slices after DIR. Quantitative evaluation was then performed in healthy adult subjects and compared with conventional DIR imaging.</p> </sec> <sec> <title>Results</title> <p>Single-slice PS-DIR provided effective blood-signal suppression over a wide range of inversion times, enhancing wall-lumen contrast and vessel wall conspicuity for carotid arteries. Multislice PS-DIR imaging with effective blood-signal suppression is enabled.</p> </sec> <sec> <title>Conclusions</title> <p>A variant of the PS-DIR method has successfully been implemented and tested for carotid vessel wall imaging. This technique removes timing constraints related to inversion recovery, enhances<abstract> <title> <x xml:space="preserve">Abstract</x> </title> <sec> <title>Objectives</title> <p>Dual-inversion recovery (DIR) is widely used for magnetic resonance vessel wall imaging. However, optimal contrast may be difficult to obtain and is subject to RR variability. Furthermore, DIR imaging is time-inefficient and multislice acquisitions may lead to prolonged scanning times. Therefore, an extension of phase-sensitive (PS) DIR is proposed for carotid vessel wall imaging.</p> </sec> <sec> <title>Methods</title> <p>The statistical distribution of the phase signal after DIR is probed to segment carotid lumens and suppress their residual blood signal. The proposed PS-DIR technique was characterized over a broad range of inversion times. Multislice imaging was then implemented by interleaving the acquisition of 3 slices after DIR. Quantitative evaluation was then performed in healthy adult subjects and compared with conventional DIR imaging.</p> </sec> <sec> <title>Results</title> <p>Single-slice PS-DIR provided effective blood-signal suppression over a wide range of inversion times, enhancing wall-lumen contrast and vessel wall conspicuity for carotid arteries. Multislice PS-DIR imaging with effective blood-signal suppression is enabled.</p> </sec> <sec> <title>Conclusions</title> <p>A variant of the PS-DIR method has successfully been implemented and tested for carotid vessel wall imaging. This technique removes timing constraints related to inversion recovery, enhances wall-lumen contrast, and enables a 3-fold increase in volumetric coverage at no extra cost in scanning time.</p> </sec> </abstract> … (more)
- Is Part Of:
- Investigative radiology. Volume 50:Issue 3(2015:Mar.)
- Journal:
- Investigative radiology
- Issue:
- Volume 50:Issue 3(2015:Mar.)
- Issue Display:
- Volume 50, Issue 3 (2015)
- Year:
- 2015
- Volume:
- 50
- Issue:
- 3
- Issue Sort Value:
- 2015-0050-0003-0000
- Page Start:
- Page End:
- Publication Date:
- 2015-03
- Subjects:
- Diagnosis, Radioscopic -- Periodicals
Radiology, Medical -- Periodicals
616.0757 - Journal URLs:
- http://journals.lww.com/investigativeradiology/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/RLI.0000000000000110 ↗
- Languages:
- English
- ISSNs:
- 0020-9996
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4560.350000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 3665.xml