Five-Year Outcome of Catheter Ablation of Persistent Atrial Fibrillation Using Termination of Atrial Fibrillation as a Procedural Endpoint. (February 2015)
- Record Type:
- Journal Article
- Title:
- Five-Year Outcome of Catheter Ablation of Persistent Atrial Fibrillation Using Termination of Atrial Fibrillation as a Procedural Endpoint. (February 2015)
- Main Title:
- Five-Year Outcome of Catheter Ablation of Persistent Atrial Fibrillation Using Termination of Atrial Fibrillation as a Procedural Endpoint
- Authors:
- Scherr, Daniel
Khairy, Paul
Miyazaki, Shinsuke
Aurillac-Lavignolle, Valerie
Pascale, Patrizio
Wilton, Stephen B.
Ramoul, Khaled
Komatsu, Yuki
Roten, Laurent
Jadidi, Amir
Linton, Nick
Pedersen, Michala
Daly, Matthew
O'Neill, Mark
Knecht, Sebastien
Weerasooriya, Rukshen
Rostock, Thomas
Manninger, Martin
Cochet, Hubert
Shah, Ashok J.
Yeim, Sunthareth
Denis, Arnaud
Derval, Nicolas
Hocini, Meleze
Sacher, Frederic
Haissaguerre, Michel
Jais, Pierre - Abstract:
- <abstract> <title> <x xml:space="preserve">Abstract</x> </title> <sec> <title>Background—</title> <p>This study aimed to determine 5-year efficacy of catheter ablation for persistent atrial fibrillation (AF) using AF termination as a procedural end point.</p> </sec> <sec> <title>Methods and Results—</title> <p>One hundred fifty patients (57±10 years) underwent persistent AF ablation using a stepwise ablation approach (pulmonary vein isolation, electrogram-guided, and linear ablation) with the desired procedural end point being AF termination. Repeat ablation was performed for recurrent AF or atrial tachycardia. AF was terminated by ablation in 120 patients (80%). Arrhythmia-free survival rates after a single procedure were 35.3%±3.9%, 28.0%±3.7%, and 16.8%±3.2% at 1, 2, and 5 years, respectively. Arrhythmia-free survival rates after the last procedure (mean 2.1±1.0 procedures) were 89.7%±2.5%, 79.8%±3.4%, and 62.9%±4.5%, at 1, 2, and 5 years, respectively. During a median follow-up of 58 (interquartile range, 43–73) months after the last ablation procedure, 97 of 150 (64.7%) patients remained in sinus rhythm without antiarrhythmic drugs. Another 14 (9.3%) patients maintained sinus rhythm after reinitiation of antiarrhythmic drugs, and an additional 15 (10.0%) patients regressed to paroxysmal recurrences only. Failure to terminate AF during the index procedure (hazard ratio 3.831; 95% confidence interval, 2.070–7.143; <italic>P</italic>&lt;0.001), left atrial diameter ≥50 mm<abstract> <title> <x xml:space="preserve">Abstract</x> </title> <sec> <title>Background—</title> <p>This study aimed to determine 5-year efficacy of catheter ablation for persistent atrial fibrillation (AF) using AF termination as a procedural end point.</p> </sec> <sec> <title>Methods and Results—</title> <p>One hundred fifty patients (57±10 years) underwent persistent AF ablation using a stepwise ablation approach (pulmonary vein isolation, electrogram-guided, and linear ablation) with the desired procedural end point being AF termination. Repeat ablation was performed for recurrent AF or atrial tachycardia. AF was terminated by ablation in 120 patients (80%). Arrhythmia-free survival rates after a single procedure were 35.3%±3.9%, 28.0%±3.7%, and 16.8%±3.2% at 1, 2, and 5 years, respectively. Arrhythmia-free survival rates after the last procedure (mean 2.1±1.0 procedures) were 89.7%±2.5%, 79.8%±3.4%, and 62.9%±4.5%, at 1, 2, and 5 years, respectively. During a median follow-up of 58 (interquartile range, 43–73) months after the last ablation procedure, 97 of 150 (64.7%) patients remained in sinus rhythm without antiarrhythmic drugs. Another 14 (9.3%) patients maintained sinus rhythm after reinitiation of antiarrhythmic drugs, and an additional 15 (10.0%) patients regressed to paroxysmal recurrences only. Failure to terminate AF during the index procedure (hazard ratio 3.831; 95% confidence interval, 2.070–7.143; <italic>P</italic>&lt;0.001), left atrial diameter ≥50 mm (hazard ratio 2.083; 95% confidence interval, 1.078–4.016; <italic>P</italic>=0.03), continuous AF duration ≥18 months (hazard ratio 1.984; 95% confidence interval, 1.024–3.846; <italic>P</italic>&lt;0.04), and structural heart disease (hazard ratio 1.874; 95% confidence interval, 1.037–3.388; <italic>P</italic>=0.04) predicted arrhythmia recurrence.</p> </sec> <sec> <title>Conclusions—</title> <p>In patients with persistent AF, an ablation strategy aiming at AF termination is associated with freedom from arrhythmia recurrence in the majority of patients over a 5-year follow-up period. Procedural AF nontermination and specific baseline factors predict long-term outcome after ablation.</p> </sec> </abstract> … (more)
- Is Part Of:
- Circulation. Volume 8:Number 1(2015)
- Journal:
- Circulation
- Issue:
- Volume 8:Number 1(2015)
- Issue Display:
- Volume 8, Issue 1 (2015)
- Year:
- 2015
- Volume:
- 8
- Issue:
- 1
- Issue Sort Value:
- 2015-0008-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2015-02
- Subjects:
- Arrhythmia -- Periodicals
Heart -- Electric properties -- Periodicals
616.128 - Journal URLs:
- http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&NEWS=n&PAGE=toc&D=ovft&AN=01337493-000000000-00000 ↗
http://circep.ahajournals.org/ ↗
http://journals.lww.com ↗ - DOI:
- 10.1161/CIRCEP.114.001943 ↗
- Languages:
- English
- ISSNs:
- 1941-3149
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3265.262500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 3016.xml