Stenting and Adjunctive Delivery of Paclitaxel Via Balloon Coating Versus Durable Polymeric Matrix for De Novo Coronary Lesions: Clinical and Angiographic Results from the Prospective Randomized Trial. (August 2015)
- Record Type:
- Journal Article
- Title:
- Stenting and Adjunctive Delivery of Paclitaxel Via Balloon Coating Versus Durable Polymeric Matrix for De Novo Coronary Lesions: Clinical and Angiographic Results from the Prospective Randomized Trial. (August 2015)
- Main Title:
- Stenting and Adjunctive Delivery of Paclitaxel Via Balloon Coating Versus Durable Polymeric Matrix for De Novo Coronary Lesions: Clinical and Angiographic Results from the Prospective Randomized Trial
- Authors:
- Żurakowski, Aleksander
Buszman, Piotr P.
Milewski, Krzysztof P.
Janas, Adam
Gorycki, Bogdan
Kondys, Marek
Gąsior, Paweł
Michalak, Magdalena
Boxberger, Michael
Peppas, Athanasios
Granada, Juan F.
Buszman, Paweł E. - Abstract:
- <abstract abstract-type="main" xml:lang="en"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="joic12210-sec-0001" sec-type="section"> <title>Background</title> <p>There is limited comparative clinical data regarding the safety and efficacy profile of paclitaxel delivery via balloon versus stent‐polymer matrix. In this study, we aimed to compare the clinical and angiographic results of two different methods of paclitaxel delivery among patients undergoing percutaneous coronary intervention (PCI) for single de novo coronary lesions.</p> </sec> <sec id="joic12210-sec-0002" sec-type="section"> <title>Methods</title> <p>A total of 202 patients undergoing PCI due to symptomatic heart disease and at least one significant coronary artery lesion were prospectively enrolled in a multicenter non‐inferiority trial. Eligible patients were randomized to a revascularization with either a paclitaxel eluting stent (PES = Coroflex Please, B.Braun) or a bare metal stent (BMS) followed by a paclitaxel coated balloon (PCB) dilation (BMS = Coroflex + PCB = Sequent Please, B.Braun). Clinical follow‐up was obtained at 9 months in all patients, whereas angiographic in a subset of 94 (46.5%) patients.</p> </sec> <sec id="joic12210-sec-0003" sec-type="section"> <title>Results</title> <p>The baseline characteristics were well balanced between groups. At 9 months, the primary endpoint of in‐stent late lumen loss in BMS + PCB was comparable and non‐inferior to PES (0.21 ± 0.5 vs.<abstract abstract-type="main" xml:lang="en"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="joic12210-sec-0001" sec-type="section"> <title>Background</title> <p>There is limited comparative clinical data regarding the safety and efficacy profile of paclitaxel delivery via balloon versus stent‐polymer matrix. In this study, we aimed to compare the clinical and angiographic results of two different methods of paclitaxel delivery among patients undergoing percutaneous coronary intervention (PCI) for single de novo coronary lesions.</p> </sec> <sec id="joic12210-sec-0002" sec-type="section"> <title>Methods</title> <p>A total of 202 patients undergoing PCI due to symptomatic heart disease and at least one significant coronary artery lesion were prospectively enrolled in a multicenter non‐inferiority trial. Eligible patients were randomized to a revascularization with either a paclitaxel eluting stent (PES = Coroflex Please, B.Braun) or a bare metal stent (BMS) followed by a paclitaxel coated balloon (PCB) dilation (BMS = Coroflex + PCB = Sequent Please, B.Braun). Clinical follow‐up was obtained at 9 months in all patients, whereas angiographic in a subset of 94 (46.5%) patients.</p> </sec> <sec id="joic12210-sec-0003" sec-type="section"> <title>Results</title> <p>The baseline characteristics were well balanced between groups. At 9 months, the primary endpoint of in‐stent late lumen loss in BMS + PCB was comparable and non‐inferior to PES (0.21 ± 0.5 vs. 0.30 ± 0.7 mm, respectively. P<sub>non‐inf</sub> &lt; 0.05). At 9 months, the incidence of MACE (7.0 vs. 6.9%, HR = 1, 95%CI: 0.3–2.8; P = 0.99), comprising the occurrence of myocardial infarction (4.9 vs. 3.0%, HR = 1.62, 95%CI: 0.4–6.5; P = 0.32), target lesion revascularization (6.9 vs. 5.0%, HR = 1.42, 95%CI: 0.4–4.4; p = 0.54) and stent thrombosis (4.9 vs. 3.0%, HR = 2.01, 95%CI: 0.5–7.4; P = 0.74) was comparable between BMS + PCB and PES, respectively. In the BMS + PCB group, thrombosis tended to occur within 30 days (3.9 vs. 1.0%; P = 0.38).</p> </sec> <sec id="joic12210-sec-0004" sec-type="section"> <title>Conclusions</title> <p>Paclitaxel delivery via drug coated balloon or polymer‐stent matrix achieved comparable angiographic and clinical results among patients with de novo coronary lesions. BMS + PCB revascularization was associated with a higher rate of stent thrombosis when compared to newer generation drug eluting stents, therefore, should be recommended as a bail‐out for PCB alone angioplasty.</p> </sec> </abstract> … (more)
- Is Part Of:
- Journal of interventional cardiology. Volume 28:Number 4(2015:Aug.)
- Journal:
- Journal of interventional cardiology
- Issue:
- Volume 28:Number 4(2015:Aug.)
- Issue Display:
- Volume 28, Issue 4 (2015)
- Year:
- 2015
- Volume:
- 28
- Issue:
- 4
- Issue Sort Value:
- 2015-0028-0004-0000
- Page Start:
- 348
- Page End:
- 357
- Publication Date:
- 2015-08
- Subjects:
- Cardiology -- Periodicals
Heart -- Diseases -- Periodicals
616.1206 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1540-8183 ↗
http://www.blackwell-synergy.com/servlet/useragent?func=showIssues&code=joic ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/joic.12210 ↗
- Languages:
- English
- ISSNs:
- 0896-4327
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5007.696000
British Library STI - ELD Digital store - Ingest File:
- 3734.xml