Wound‐related complications and clinical outcomes following open globe injury repair. (19th June 2015)
- Record Type:
- Journal Article
- Title:
- Wound‐related complications and clinical outcomes following open globe injury repair. (19th June 2015)
- Main Title:
- Wound‐related complications and clinical outcomes following open globe injury repair
- Authors:
- Kong, George YX
Henderson, Robert H
Sandhu, Sukhpal S
Essex, Rohan W
Allen, Penelope J
Campbell, William G - Abstract:
- <abstract abstract-type="main"> <title>Abstract</title> <sec id="ceo12511-sec-0001" sec-type="section"> <title>Background</title> <p>Careful surgical management of traumatic wounds is important in open globe injury repair. This study examines the clinical outcomes following repair of open globe injuries with particular focus on wound‐related issues.</p> </sec> <sec id="ceo12511-sec-0002" sec-type="section"> <title>Design</title> <p>Retrospective, cohort study of consecutive open globe injuries presenting to a tertiary referral eye hospital from 1 January 2009 to 31 December 2011.</p> </sec> <sec id="ceo12511-sec-0003" sec-type="section"> <title>Participants</title> <p>A total of 267 eyes of 263 patients, mainly male (82.5%) with a mean age of 44.8 (range: 4–97) years. Average follow up was 6.9 months.</p> </sec> <sec id="ceo12511-sec-0004" sec-type="section"> <title>Methods</title> <p>All cases classified according to Ocular Trauma Classification Group.</p> </sec> <sec id="ceo12511-sec-0005" sec-type="section"> <title>Main Outcome Measures</title> <p>Visual outcomes, risk factors for and rates of postoperative complications and endophthalmitis.</p> </sec> <sec id="ceo12511-sec-0006" sec-type="section"> <title>Results</title> <p>There were 83 globe ruptures, 182 penetrating and 2 perforating eye injuries, of which 43 cases had intraocular foreign body. Factors contributing to final visual acuity (VA) &lt;6/60 were poor presenting VA (odds ratio [OR] = 16.0, 95% confidence<abstract abstract-type="main"> <title>Abstract</title> <sec id="ceo12511-sec-0001" sec-type="section"> <title>Background</title> <p>Careful surgical management of traumatic wounds is important in open globe injury repair. This study examines the clinical outcomes following repair of open globe injuries with particular focus on wound‐related issues.</p> </sec> <sec id="ceo12511-sec-0002" sec-type="section"> <title>Design</title> <p>Retrospective, cohort study of consecutive open globe injuries presenting to a tertiary referral eye hospital from 1 January 2009 to 31 December 2011.</p> </sec> <sec id="ceo12511-sec-0003" sec-type="section"> <title>Participants</title> <p>A total of 267 eyes of 263 patients, mainly male (82.5%) with a mean age of 44.8 (range: 4–97) years. Average follow up was 6.9 months.</p> </sec> <sec id="ceo12511-sec-0004" sec-type="section"> <title>Methods</title> <p>All cases classified according to Ocular Trauma Classification Group.</p> </sec> <sec id="ceo12511-sec-0005" sec-type="section"> <title>Main Outcome Measures</title> <p>Visual outcomes, risk factors for and rates of postoperative complications and endophthalmitis.</p> </sec> <sec id="ceo12511-sec-0006" sec-type="section"> <title>Results</title> <p>There were 83 globe ruptures, 182 penetrating and 2 perforating eye injuries, of which 43 cases had intraocular foreign body. Factors contributing to final visual acuity (VA) &lt;6/60 were poor presenting VA (odds ratio [OR] = 16.0, 95% confidence interval [CI]: 4.81–53.1), globe rupture (OR = 4.64, [1.99–10.8]), retinal detachment (OR = 3.40, [1.19–9.74]) and age ≥50 (OR = 2.45, [1.05–5.74]). Wound leak occurred in 44 eyes (16%). Of these, 18 (41%) proceeded to re‐suturing. Factors contributing to wound leak were stellate‐shaped wound (OR = 3.28, [1.39–7.73]) and delayed presentation (OR = 2.80, [1.02–7.71]). Ten eyes (3.7%) developed endophthalmitis. Factors associated with endophthalmitis were delayed presentation (OR = 8.91, [1.71–46.6]), microbial keratitis (OR = 12.5, [1.85–85.0]) and lens capsule breach (OR = 12.4, [1.85–83.1]).</p> </sec> <sec id="ceo12511-sec-0007" sec-type="section"> <title>Conclusions</title> <p>Wound leak is an important postoperative complication of open globe injury repair. Delayed presentation is an important risk factor for postoperative wound leak and endophthalmitis. Prompt and meticulous wound management of open globe injury may reduce these complications.</p> </sec> </abstract> … (more)
- Is Part Of:
- Clinical & experimental ophthalmology. Volume 43:Number 6(2015)
- Journal:
- Clinical & experimental ophthalmology
- Issue:
- Volume 43:Number 6(2015)
- Issue Display:
- Volume 43, Issue 6 (2015)
- Year:
- 2015
- Volume:
- 43
- Issue:
- 6
- Issue Sort Value:
- 2015-0043-0006-0000
- Page Start:
- 508
- Page End:
- 513
- Publication Date:
- 2015-06-19
- Subjects:
- Ophthalmology -- Periodicals
617.7 - Journal URLs:
- http://www.blackwellpublishing.com/journal.asp?ref=1442-6404&site=1 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/ceo.12511 ↗
- Languages:
- English
- ISSNs:
- 1442-6404
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.251920
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 3032.xml