Peripheral nerve stimulation‐optimal gradient waveform design. Issue 2 (28th August 2014)
- Record Type:
- Journal Article
- Title:
- Peripheral nerve stimulation‐optimal gradient waveform design. Issue 2 (28th August 2014)
- Main Title:
- Peripheral nerve stimulation‐optimal gradient waveform design
- Authors:
- Schulte, Rolf F.
Noeske, Ralph - Abstract:
- <abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="mrm25440-sec-0001" sec-type="section"> <title>Purpose</title> <p>Modern magnetic resonance imaging scanners with high‐performance gradient systems have high maximum gradient strength (<italic>G</italic><sub>max</sub>) and slew rate (<italic>S</italic><sub>max</sub>). Peripheral nerve stimulation (PNS) is often a more limiting factor for gradient waveform design than <italic>G</italic><sub>max</sub> and <italic>S</italic><sub>max</sub>. Traditionally, the slew rate is derated globally to adhere to PNS limitations.</p> </sec> <sec id="mrm25440-sec-0002" sec-type="section"> <title>Methods</title> <p>In this work, the PNS limitation is already included in the gradient waveform design in the form of a time‐varying slew rate, hence shortening the overall gradient duration.</p> </sec> <sec id="mrm25440-sec-0003" sec-type="section"> <title>Results</title> <p>Spiral and echo‐planar imaging trajectories were designed with a multitude of parameters, and it was demonstrated that trajectory durations from conventional to PNS‐optimal design can be shortened by 8 and 3%, respectively.</p> </sec> <sec id="mrm25440-sec-0004" sec-type="section"> <title>Conclusion</title> <p>Including PNS‐limits in the gradient waveform design can shorten the duration of gradient trajectories, thereby reducing associated artifacts. Magn Reson Med 74:518–522, 2015. © 2014 Wiley Periodicals, Inc.</p> </sec> </abstract>
- Is Part Of:
- Magnetic resonance in medicine. Volume 74:Issue 2(2015:Aug.)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 74:Issue 2(2015:Aug.)
- Issue Display:
- Volume 74, Issue 2 (2015)
- Year:
- 2015
- Volume:
- 74
- Issue:
- 2
- Issue Sort Value:
- 2015-0074-0002-0000
- Page Start:
- 518
- Page End:
- 522
- Publication Date:
- 2014-08-28
- Subjects:
- Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.25440 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 3199.xml