Electrophysiologic monitoring correlates of recurrent laryngeal nerve heat thermal injury in a porcine model. (22nd May 2015)
- Record Type:
- Journal Article
- Title:
- Electrophysiologic monitoring correlates of recurrent laryngeal nerve heat thermal injury in a porcine model. (22nd May 2015)
- Main Title:
- Electrophysiologic monitoring correlates of recurrent laryngeal nerve heat thermal injury in a porcine model
- Authors:
- Lin, Yi‐Chu
Dionigi, Gianlorenzo
Randolph, Gregory W.
Lu, I‐Cheng
Chang, Pi‐Ying
Tsai, Shan‐Yin
Kim, Hoon Yub
Lee, Hye Yoon
Tufano, Ralph P.
Sun, Hui
Liu, Xiaoli
Chiang, Feng‐Yu
Wu, Che‐Wei - Abstract:
- <abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="lary25362-sec-0001" sec-type="section"> <title>Objectives/Hypothesis</title> <p>Thermal injury to the recurrent laryngeal nerve (RLN) may not be visually apparent and may go unrecognized intraoperatively. This study aimed to investigate the heat thermal tolerance of RLN and evaluate the electrophysiologic correlates of electromyographic (EMG) signal change during an acute RLN heat damage.</p> </sec> <sec id="lary25362-sec-0002" sec-type="section"> <title>Study Design</title> <p>Prospective porcine model with continuous intraoperative neuromonitoring (CIONM).</p> </sec> <sec id="lary25362-sec-0003" sec-type="section"> <title>Methods</title> <p>Ten pigs (20 RLNs) undergoing CIONM had their EMG tracings recorded and correlated with heated normal saline (NS) irrigation of varying temperature and duration.</p> </sec> <sec id="lary25362-sec-0004" sec-type="section"> <title>Results</title> <p>In the initial pilot study, the EMG was without change during incremental heated NS irrigation (40/45/50/55 °C for 60 seconds), but adverse EMG combined events (CE) (amplitude decrease with a concordant latency increase) occurred and degraded to loss of signal (LOS) (by 17.5 ± 1.3 seconds) when the temperature was elevated to 60 °C (n = 4). Another 16 RLNs were evaluated to further compare the EMG pattern after various degrees of thermal stress (60/70 °C for 30/20 seconds). Electromyographic<abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="lary25362-sec-0001" sec-type="section"> <title>Objectives/Hypothesis</title> <p>Thermal injury to the recurrent laryngeal nerve (RLN) may not be visually apparent and may go unrecognized intraoperatively. This study aimed to investigate the heat thermal tolerance of RLN and evaluate the electrophysiologic correlates of electromyographic (EMG) signal change during an acute RLN heat damage.</p> </sec> <sec id="lary25362-sec-0002" sec-type="section"> <title>Study Design</title> <p>Prospective porcine model with continuous intraoperative neuromonitoring (CIONM).</p> </sec> <sec id="lary25362-sec-0003" sec-type="section"> <title>Methods</title> <p>Ten pigs (20 RLNs) undergoing CIONM had their EMG tracings recorded and correlated with heated normal saline (NS) irrigation of varying temperature and duration.</p> </sec> <sec id="lary25362-sec-0004" sec-type="section"> <title>Results</title> <p>In the initial pilot study, the EMG was without change during incremental heated NS irrigation (40/45/50/55 °C for 60 seconds), but adverse EMG combined events (CE) (amplitude decrease with a concordant latency increase) occurred and degraded to loss of signal (LOS) (by 17.5 ± 1.3 seconds) when the temperature was elevated to 60 °C (n = 4). Another 16 RLNs were evaluated to further compare the EMG pattern after various degrees of thermal stress (60/70 °C for 30/20 seconds). Electromyographic recordings showed CEs and LOS in all RLNs, and only six of eight RLNs with 60 °C exposure showed slight EMG amplitude recovery (16%–35%) after 20 minutes. None of the injured nerve segments were visually apparent, but all were detectable by IONM.</p> </sec> <sec id="lary25362-sec-0005" sec-type="section"> <title>Conclusion</title> <p>Sixty degrees Celsius is a critical temperature to cause RLN thermal injury. Continuous intraoperative neuromonitoring can be used as a tool for the early detection of acute thermal stress and may guide use of energy‐based devices during thyroid procedures.</p> </sec> <sec id="lary25362-sec-0006" sec-type="section"> <title>Level of Evidence</title> <p>N/A. <italic>Laryngoscope</italic>, 125:E283–E290, 2015</p> </sec> </abstract> … (more)
- Is Part Of:
- Laryngoscope. Volume 125:Number 8(2015:Aug.)
- Journal:
- Laryngoscope
- Issue:
- Volume 125:Number 8(2015:Aug.)
- Issue Display:
- Volume 125, Issue 8 (2015)
- Year:
- 2015
- Volume:
- 125
- Issue:
- 8
- Issue Sort Value:
- 2015-0125-0008-0000
- Page Start:
- E283
- Page End:
- E290
- Publication Date:
- 2015-05-22
- Subjects:
- Otolaryngology -- Periodicals
617.51005 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1531-4995/issues ↗
http://www.interscience.wiley.com/jpages/0023-852X ↗
http://www.laryngoscope.com ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/lary.25362 ↗
- Languages:
- English
- ISSNs:
- 0023-852X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5156.200000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 3398.xml