Multi-subject atlas-based auto-segmentation reduces interobserver variation and improves dosimetric parameter consistency for organs at risk in nasopharyngeal carcinoma: A multi-institution clinical study. Issue 3 (June 2015)
- Record Type:
- Journal Article
- Title:
- Multi-subject atlas-based auto-segmentation reduces interobserver variation and improves dosimetric parameter consistency for organs at risk in nasopharyngeal carcinoma: A multi-institution clinical study. Issue 3 (June 2015)
- Main Title:
- Multi-subject atlas-based auto-segmentation reduces interobserver variation and improves dosimetric parameter consistency for organs at risk in nasopharyngeal carcinoma: A multi-institution clinical study
- Authors:
- Tao, Chang-Juan
Yi, Jun-Lin
Chen, Nian-Yong
Ren, Wei
Cheng, Jason
Tung, Stewart
Kong, Lin
Lin, Shao-Jun
Pan, Jian-Ji
Zhang, Guang-Shun
Hu, Jiang
Qi, Zhen-Yu
Ma, Jun
Lu, Jia-De
Yan, Di
Sun, Ying - Abstract:
- <abstract xml:lang="en" abstract-type="author" id="ab005"> <title id="st005">Abstract</title> <sec> <title id="st010">Background and purpose</title> <p id="sp0005">To assess whether consensus guideline-based atlas-based auto-segmentation (ABAS) reduces interobserver variation and improves dosimetric parameter consistency for organs at risk (OARs) in nasopharyngeal carcinoma (NPC).</p> </sec> <sec> <title id="st015">Materials and methods</title> <p id="sp0010">Eight radiation oncologists from 8 institutes contoured 20 OARs on planning CT images of 16 patients via manual contouring and manually-edited ABAS contouring. Interobserver variation [volume coefficient of variation (CV), Dice similarity coefficient (DSC), three-dimensional isocenter difference (3D-ICD)] and dosimetric parameters were compared between the two methods of contouring for each OAR.</p> </sec> <sec> <title id="st020">Results</title> <p id="sp0015">Interobserver variation was significant for all OARs in manual contouring, resulting in significant dosimetric parameter variation (<italic>P</italic> &lt; 0.05). Edited ABAS significantly improved multiple metrics and reduced dosimetric parameter variation for most OARs; brainstem, spinal cord, cochleae, temporomandibular joint (TMJ), larynx and pharyngeal constrictor muscle (PCM) obtained most benefit (range of mean DSC, volume CV and main ICD values was 0.36–0.83, 12.1–84.3%, 2.2–5.0 mm for manual contouring and 0.42–0.86, 7.2–70.6%, 1.2–3.5 mm for edited ABAS<abstract xml:lang="en" abstract-type="author" id="ab005"> <title id="st005">Abstract</title> <sec> <title id="st010">Background and purpose</title> <p id="sp0005">To assess whether consensus guideline-based atlas-based auto-segmentation (ABAS) reduces interobserver variation and improves dosimetric parameter consistency for organs at risk (OARs) in nasopharyngeal carcinoma (NPC).</p> </sec> <sec> <title id="st015">Materials and methods</title> <p id="sp0010">Eight radiation oncologists from 8 institutes contoured 20 OARs on planning CT images of 16 patients via manual contouring and manually-edited ABAS contouring. Interobserver variation [volume coefficient of variation (CV), Dice similarity coefficient (DSC), three-dimensional isocenter difference (3D-ICD)] and dosimetric parameters were compared between the two methods of contouring for each OAR.</p> </sec> <sec> <title id="st020">Results</title> <p id="sp0015">Interobserver variation was significant for all OARs in manual contouring, resulting in significant dosimetric parameter variation (<italic>P</italic> &lt; 0.05). Edited ABAS significantly improved multiple metrics and reduced dosimetric parameter variation for most OARs; brainstem, spinal cord, cochleae, temporomandibular joint (TMJ), larynx and pharyngeal constrictor muscle (PCM) obtained most benefit (range of mean DSC, volume CV and main ICD values was 0.36–0.83, 12.1–84.3%, 2.2–5.0 mm for manual contouring and 0.42–0.86, 7.2–70.6%, 1.2–3.5 mm for edited ABAS contouring, respectively; range of dose CV reduction: 1.0–3.0%).</p> </sec> <sec> <title id="st025">Conclusion</title> <p id="sp0020">Substantial objective interobserver differences occur during manual contouring, resulting in significant dosimetric parameter variation. Edited ABAS reduced interobserver variation and improved dosimetric parameter consistency, particularly for brainstem, spinal cord, cochleae, TMJ, larynx and PCM.</p> </sec> </abstract> … (more)
- Is Part Of:
- Radiotherapy and oncology. Volume 115:Issue 3(2015:Jun.)
- Journal:
- Radiotherapy and oncology
- Issue:
- Volume 115:Issue 3(2015:Jun.)
- Issue Display:
- Volume 115, Issue 3 (2015)
- Year:
- 2015
- Volume:
- 115
- Issue:
- 3
- Issue Sort Value:
- 2015-0115-0003-0000
- Page Start:
- 407
- Page End:
- 411
- Publication Date:
- 2015-06
- Subjects:
- Oncology -- Periodicals
Radiotherapy -- Periodicals
Tumors -- Periodicals
Medical Oncology -- Periodicals
Neoplasms -- radiotherapy -- Periodicals
Radiotherapy -- Periodicals
Radiothérapie -- Périodiques
Cancérologie -- Périodiques
Tumeurs -- Périodiques
Electronic journals
616.9940642 - Journal URLs:
- http://www.sciencedirect.com/science/journal/01678140 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/01678140 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/01678140 ↗
http://www.estro.org/ ↗
http://www.elsevier.com/journals ↗
http://www.journals.elsevier.com/radiotherapy-and-oncology/ ↗ - DOI:
- 10.1016/j.radonc.2015.05.012 ↗
- Languages:
- English
- ISSNs:
- 0167-8140
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7240.790000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 3548.xml