Automated left ventricle segmentation in late gadolinium‐enhanced MRI for objective myocardial scar assessment. Issue 2 (19th November 2014)
- Record Type:
- Journal Article
- Title:
- Automated left ventricle segmentation in late gadolinium‐enhanced MRI for objective myocardial scar assessment. Issue 2 (19th November 2014)
- Main Title:
- Automated left ventricle segmentation in late gadolinium‐enhanced MRI for objective myocardial scar assessment
- Authors:
- Tao, Qian
Piers, Sebastiaan R.D.
Lamb, Hildo J.
van der Geest, Rob J. - Abstract:
- <abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="jmri24804-sec-0001" sec-type="section"> <title>Purpose</title> <p>To develop and validate an objective and reproducible left ventricle (LV) segmentation method for late gadolinium enhanced (LGE) magnetic resonance imaging (MRI), which can facilitate accurate myocardial scar assessment.</p> </sec> <sec id="jmri24804-sec-0002" sec-type="section"> <title>Materials and Methods</title> <p>A cohort of 25 ischemic patients and 25 nonischemic patients were included. A four‐step algorithm was proposed: first, the Cine‐MRI and LGE‐MRI volume were globally registered; second, the registered Cine‐MRI contours were fitted to each LGE‐MRI slice via the constructed contour image; third, the fitting was optimized in full LGE‐MRI stack; finally, the contours were refined by taking into account patient‐specific scar patterns. The automated LV segmentation results were compared with that of manual segmentation from two experienced observers.</p> </sec> <sec id="jmri24804-sec-0003" sec-type="section"> <title>Results</title> <p>The accuracy of automated segmentation, expressed as the average contour distances to manual segmentation, was 0.82 ± 0.19 pixels, in the same order as interobserver difference between manual results (0.90 ± 0.26 pixels), but with lower variability (0.60 ± 0.37 pixels, <italic>P &lt;</italic> 0.05). The myocardial scar identification based on automated LV segmentation further<abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="jmri24804-sec-0001" sec-type="section"> <title>Purpose</title> <p>To develop and validate an objective and reproducible left ventricle (LV) segmentation method for late gadolinium enhanced (LGE) magnetic resonance imaging (MRI), which can facilitate accurate myocardial scar assessment.</p> </sec> <sec id="jmri24804-sec-0002" sec-type="section"> <title>Materials and Methods</title> <p>A cohort of 25 ischemic patients and 25 nonischemic patients were included. A four‐step algorithm was proposed: first, the Cine‐MRI and LGE‐MRI volume were globally registered; second, the registered Cine‐MRI contours were fitted to each LGE‐MRI slice via the constructed contour image; third, the fitting was optimized in full LGE‐MRI stack; finally, the contours were refined by taking into account patient‐specific scar patterns. The automated LV segmentation results were compared with that of manual segmentation from two experienced observers.</p> </sec> <sec id="jmri24804-sec-0003" sec-type="section"> <title>Results</title> <p>The accuracy of automated segmentation, expressed as the average contour distances to manual segmentation, was 0.82 ± 0.19 pixels, in the same order as interobserver difference between manual results (0.90 ± 0.26 pixels), but with lower variability (0.60 ± 0.37 pixels, <italic>P &lt;</italic> 0.05). The myocardial scar identification based on automated LV segmentation further demonstrated higher consistency than that of manual segmentation (Pearson correlation 0.97 vs. 0.84).</p> </sec> <sec id="jmri24804-sec-0004" sec-type="section"> <title>Conclusion</title> <p>An automated LV segmentation method for LGE‐MRI was developed, providing high segmentation accuracy and lower interobserver variability compared to fully manual image analysis. The method facilitates objective assessment of myocardial scar. J. Magn. Reson. Imaging 2015;42:390–399.</p> </sec> </abstract> … (more)
- Is Part Of:
- Journal of magnetic resonance imaging. Volume 42:Issue 2(2015)
- Journal:
- Journal of magnetic resonance imaging
- Issue:
- Volume 42:Issue 2(2015)
- Issue Display:
- Volume 42, Issue 2 (2015)
- Year:
- 2015
- Volume:
- 42
- Issue:
- 2
- Issue Sort Value:
- 2015-0042-0002-0000
- Page Start:
- 390
- Page End:
- 399
- Publication Date:
- 2014-11-19
- Subjects:
- Magnetic resonance imaging -- Periodicals
616 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2586 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jmri.24804 ↗
- Languages:
- English
- ISSNs:
- 1053-1807
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5010.791000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File: