Combining fluorescence and bioluminescence microscopy. Issue 8 (19th June 2015)
- Record Type:
- Journal Article
- Title:
- Combining fluorescence and bioluminescence microscopy. Issue 8 (19th June 2015)
- Main Title:
- Combining fluorescence and bioluminescence microscopy
- Authors:
- Goda, Kazuhito
Hatta‐Ohashi, Yoko
Akiyoshi, Ryutaro
Sugiyama, Takashi
Sakai, Ikuko
Takahashi, Takeo
Suzuki, Hirobumi - Abstract:
- <abstract abstract-type="main"> <title>ABSTRACT</title> <p>Bioluminescence microscopy has revealed that gene expression in individual cells can respond differently to the same stimulus. To understand this phenomenon, it is important to sequentially observe the series of events from cellular signal transduction to gene expression regulated by specific transcription factors derived from signaling cascades in individual cells. However, these processes have been separately analyzed with fluorescence and bioluminescence microscopy. Furthermore, in culture medium, the background fluorescence of luciferin—a substrate of luciferase in promoter assays of gene expression in cultured cells—confounds the simultaneous observation of fluorescence and bioluminescence. Therefore, we optimized conditions for optical filter sets based on spectral properties and the luciferin concentration based on cell permeability for fluorescence observation combined with bioluminescence microscopy. An excitation and emission filter set (492–506 nm and 524–578 nm) was suitable for green fluorescent protein and yellow fluorescent protein imaging of cells, and &gt;100 μM luciferin was acceptable in culture medium based on kinetic constants and the estimated intracellular concentration. Using these parameters, we present an example of sequential fluorescence and bioluminescence microscopic observation of signal transduction (translocation of protein kinase C alpha from the cytoplasm to the plasma membrane)<abstract abstract-type="main"> <title>ABSTRACT</title> <p>Bioluminescence microscopy has revealed that gene expression in individual cells can respond differently to the same stimulus. To understand this phenomenon, it is important to sequentially observe the series of events from cellular signal transduction to gene expression regulated by specific transcription factors derived from signaling cascades in individual cells. However, these processes have been separately analyzed with fluorescence and bioluminescence microscopy. Furthermore, in culture medium, the background fluorescence of luciferin—a substrate of luciferase in promoter assays of gene expression in cultured cells—confounds the simultaneous observation of fluorescence and bioluminescence. Therefore, we optimized conditions for optical filter sets based on spectral properties and the luciferin concentration based on cell permeability for fluorescence observation combined with bioluminescence microscopy. An excitation and emission filter set (492–506 nm and 524–578 nm) was suitable for green fluorescent protein and yellow fluorescent protein imaging of cells, and &gt;100 μM luciferin was acceptable in culture medium based on kinetic constants and the estimated intracellular concentration. Using these parameters, we present an example of sequential fluorescence and bioluminescence microscopic observation of signal transduction (translocation of protein kinase C alpha from the cytoplasm to the plasma membrane) coupled with activation of gene expression by nuclear factor of kappa light polypeptide B in individual cells and show that the gene expression response is not completely concordant with upstream signaling following stimulation with phorbol‐12‐myristate‐13‐acetate. Our technique is a powerful imaging tool for analysis of heterogeneous gene expression together with upstream signaling in live single cells. <italic>Microsc. Res. Tech. 78:715–722, 2015</italic>. © 2015 Wiley Periodicals, Inc.</p> </abstract> … (more)
- Is Part Of:
- Microscopy research and technique. Volume 78:Issue 8(2015:Aug.)
- Journal:
- Microscopy research and technique
- Issue:
- Volume 78:Issue 8(2015:Aug.)
- Issue Display:
- Volume 78, Issue 8 (2015)
- Year:
- 2015
- Volume:
- 78
- Issue:
- 8
- Issue Sort Value:
- 2015-0078-0008-0000
- Page Start:
- 715
- Page End:
- 722
- Publication Date:
- 2015-06-19
- Subjects:
- Electron microscopy -- Technique -- Periodicals
Microscopy -- Periodicals
Microscopy -- Technique -- Periodicals
502.825 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1097-0029 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jemt.22529 ↗
- Languages:
- English
- ISSNs:
- 1059-910X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5760.600850
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 3256.xml