Inability of Turbidimetry Method in Detecting Glycated Hemoglobin to Select Diabetes Mellitus Patients According to Their Concentrations of Blood Glucose Levels. Issue 4 (17th August 2014)
- Record Type:
- Journal Article
- Title:
- Inability of Turbidimetry Method in Detecting Glycated Hemoglobin to Select Diabetes Mellitus Patients According to Their Concentrations of Blood Glucose Levels. Issue 4 (17th August 2014)
- Main Title:
- Inability of Turbidimetry Method in Detecting Glycated Hemoglobin to Select Diabetes Mellitus Patients According to Their Concentrations of Blood Glucose Levels
- Authors:
- Abdallah, Alessandra M.
Alves, Beatriz C. A.
Gehrke, Flávia S.
Sant´Ana, Aleksandra V. L.
Azzalis, Ligia A.
Junqueira, Virginia B. C.
Adami, Fernando
Pereira, Edimar C.
Fonseca, Fernando L. A. - Abstract:
- <abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="jcla21771-sec-0010" sec-type="section"> <title>Background</title> <p>Diabetes mellitus is a chronicle illness in which there is a high blood glucose level defined as hyperglycemia, resulted by a deficiency in insulin secretion and/or in its action. Nowadays, it is being seen as a public health problem and is reaching increasing proportions with regard to the appearance of new cases. For diagnosis, sensible and accurate methods should be used to avoid complications of the sickness. The measure of glycated hemoglobin may not be used for diagnosis, but is the reference method to evaluate the grade of glycemic control in the long term, reflecting the blood glucose level in the latest 2–3 months. The aim of this study was to evaluate the grade of concordance between turbidimetry and liquid chromatography methods in the glycated hemoglobin determination and to estimate the sensibility and specificity values of turbidimetry.</p> </sec> <sec id="jcla21771-sec-0020" sec-type="section"> <title>Methods</title> <p>This study included 133 blood samples obtained from patients and healthy donors, ageing between 18 and 80 years with glycemic values between 58 and 473 mg/dl.</p> </sec> <sec id="jcla21771-sec-0030" sec-type="section"> <title>Results and Conclusion</title> <p>Turbidimetry is a useful method for determining glycemic levels above 100 and over 200 mg/dl, but does not have the ability to<abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="jcla21771-sec-0010" sec-type="section"> <title>Background</title> <p>Diabetes mellitus is a chronicle illness in which there is a high blood glucose level defined as hyperglycemia, resulted by a deficiency in insulin secretion and/or in its action. Nowadays, it is being seen as a public health problem and is reaching increasing proportions with regard to the appearance of new cases. For diagnosis, sensible and accurate methods should be used to avoid complications of the sickness. The measure of glycated hemoglobin may not be used for diagnosis, but is the reference method to evaluate the grade of glycemic control in the long term, reflecting the blood glucose level in the latest 2–3 months. The aim of this study was to evaluate the grade of concordance between turbidimetry and liquid chromatography methods in the glycated hemoglobin determination and to estimate the sensibility and specificity values of turbidimetry.</p> </sec> <sec id="jcla21771-sec-0020" sec-type="section"> <title>Methods</title> <p>This study included 133 blood samples obtained from patients and healthy donors, ageing between 18 and 80 years with glycemic values between 58 and 473 mg/dl.</p> </sec> <sec id="jcla21771-sec-0030" sec-type="section"> <title>Results and Conclusion</title> <p>Turbidimetry is a useful method for determining glycemic levels above 100 and over 200 mg/dl, but does not have the ability to select samples with intermediary blood glucose concentrations.</p> </sec> </abstract> … (more)
- Is Part Of:
- Journal of clinical laboratory analysis. Volume 29:Issue 4(2015)
- Journal:
- Journal of clinical laboratory analysis
- Issue:
- Volume 29:Issue 4(2015)
- Issue Display:
- Volume 29, Issue 4 (2015)
- Year:
- 2015
- Volume:
- 29
- Issue:
- 4
- Issue Sort Value:
- 2015-0029-0004-0000
- Page Start:
- 312
- Page End:
- 316
- Publication Date:
- 2014-08-17
- Subjects:
- Diagnosis, Laboratory -- Periodicals
Medical laboratory technology -- Periodicals
616 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1002/jcla.21771 ↗
- Languages:
- English
- ISSNs:
- 0887-8013
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4958.520000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 4126.xml