Trans‐pulmonary echocardiography as a guide for device closure of patent ductus arteriosus. Issue 2 (25th February 2015)
- Record Type:
- Journal Article
- Title:
- Trans‐pulmonary echocardiography as a guide for device closure of patent ductus arteriosus. Issue 2 (25th February 2015)
- Main Title:
- Trans‐pulmonary echocardiography as a guide for device closure of patent ductus arteriosus
- Authors:
- Kudo, Yoshiyuki
Suda, Kenji
Yoshimoto, Hironaga
Teramachi, Yozo
Kishimoto, Shintaro
Iemura, Motofumi
Matsuishi, Toyojiro - Abstract:
- <abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="ccd25879-sec-0001" sec-type="section"> <title>Objectives</title> <p>The aim of this study was to develop trans‐pulmonary echocardiography (TPE) to guide device closure of patent ductus arteriosus (DC‐PDA).</p> </sec> <sec id="ccd25879-sec-0002" sec-type="section"> <title>Background</title> <p>Aortography requires a large amount of contrast yet may give us an inadequate image to evaluate anatomy or residual shunt in patients with large PDA or dilated vessels and is precluded in patients with renal dysfunction. Practically, there is no imaging modality to monitor the entire procedure except for trans‐esophageal echocardiography that requires general anesthesia.</p> </sec> <sec id="ccd25879-sec-0003" sec-type="section"> <title>Methods</title> <p>Subjects were seven patients with ages ranged from 6‐ to 77‐years old and body weight &gt; 15 kg. The size of the PDA ranged from 1.8 to 6.3 mm with pulmonary to systemic flow ratios from 1.2 to 2.2. During DC‐PDA using Ampaltzer Duct Occluder or coil, an intra‐cardiac echocardiographic (ICE) catheter was advanced into pulmonary arteries and standard views were developed to guide DC‐PDA.</p> </sec> <sec id="ccd25879-sec-0004" sec-type="section"> <title>Results</title> <p>We have developed two standard views; the main pulmonary artery view (MPA view) and the left pulmonary artery view (LPA view). The MPA view provided aortic short axis view<abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="ccd25879-sec-0001" sec-type="section"> <title>Objectives</title> <p>The aim of this study was to develop trans‐pulmonary echocardiography (TPE) to guide device closure of patent ductus arteriosus (DC‐PDA).</p> </sec> <sec id="ccd25879-sec-0002" sec-type="section"> <title>Background</title> <p>Aortography requires a large amount of contrast yet may give us an inadequate image to evaluate anatomy or residual shunt in patients with large PDA or dilated vessels and is precluded in patients with renal dysfunction. Practically, there is no imaging modality to monitor the entire procedure except for trans‐esophageal echocardiography that requires general anesthesia.</p> </sec> <sec id="ccd25879-sec-0003" sec-type="section"> <title>Methods</title> <p>Subjects were seven patients with ages ranged from 6‐ to 77‐years old and body weight &gt; 15 kg. The size of the PDA ranged from 1.8 to 6.3 mm with pulmonary to systemic flow ratios from 1.2 to 2.2. During DC‐PDA using Ampaltzer Duct Occluder or coil, an intra‐cardiac echocardiographic (ICE) catheter was advanced into pulmonary arteries and standard views were developed to guide DC‐PDA.</p> </sec> <sec id="ccd25879-sec-0004" sec-type="section"> <title>Results</title> <p>We have developed two standard views; the main pulmonary artery view (MPA view) and the left pulmonary artery view (LPA view). The MPA view provided aortic short axis view equivalent to that seen by trans‐thoracic echocardiography in children. The LPA view, obtained by the echo probe in the LPA and turned it up upside down, provided long axis view of the PDA allowing more precise anatomical evaluation. TPE allowed us to monitor the entire procedure and determine residual shunts.</p> </sec> <sec id="ccd25879-sec-0005" sec-type="section"> <title>Conclusions</title> <p>TPE in the MPA and LPA view can be an effective guide for DC‐PDA. This report leads to new application of this imaging device. © 2015 Wiley Periodicals, Inc.</p> </sec> </abstract> … (more)
- Is Part Of:
- Catheterization and cardiovascular interventions. Volume 86:Issue 2(2015:Aug. 01)
- Journal:
- Catheterization and cardiovascular interventions
- Issue:
- Volume 86:Issue 2(2015:Aug. 01)
- Issue Display:
- Volume 86, Issue 2 (2015)
- Year:
- 2015
- Volume:
- 86
- Issue:
- 2
- Issue Sort Value:
- 2015-0086-0002-0000
- Page Start:
- 264
- Page End:
- 270
- Publication Date:
- 2015-02-25
- Subjects:
- Heart -- Diseases -- Diagnosis -- Periodicals
Cardiac catheterization -- Periodicals
616.1207572 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-726X ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/ccd.25879 ↗
- Languages:
- English
- ISSNs:
- 1522-1946
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3092.992000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 3593.xml