Fluid dynamics and intraocular pressure using venturi phacoemulsification machine in dogs ex vivo. (27th October 2014)
- Record Type:
- Journal Article
- Title:
- Fluid dynamics and intraocular pressure using venturi phacoemulsification machine in dogs ex vivo. (27th October 2014)
- Main Title:
- Fluid dynamics and intraocular pressure using venturi phacoemulsification machine in dogs ex vivo
- Authors:
- Kang, Seonmi
Park, Sangwan
Noh, Hyunwoo
Seo, Kangmoon - Abstract:
- <abstract abstract-type="main" id="vop12231-abs-0001"> <title>Abstract</title> <sec id="vop12231-sec-0001" sec-type="section"> <title>Objective</title> <p>To optimize fluid dynamics through measuring intraocular pressure (IOP) in a venturi phacoemulsification machine in dogs.</p> </sec> <sec id="vop12231-sec-0002" sec-type="section"> <title>Procedures</title> <p>In step I, flow and IOP of the test chamber were measured using a pressure transducer with the bottle height (BH) set at 50, 70, 100, and 120 cm and the vacuum from 30 to 450 mmHg. A 19‐gauge phaco and a 0.3‐mm irrigation/aspiration (I/A) handpiece were used. In step II, flow and IOP were measured in an enucleated canine eye with a 3.0‐ and a 3.2‐mm clear corneal incision (CCI), respectively. IOP was measured using the pressure transducer at a 30‐mmHg vacuum to allow corneal deformation, to define the fluidic parameters for preventing surge.</p> </sec> <sec id="vop12231-sec-0003" sec-type="section"> <title>Results</title> <p>Flow was directly proportional to the BH and vacuum, whereas IOP was directly proportional to the BH and inversely to the vacuum. Flow with an I/A handpiece was significantly less than with a phaco handpiece, explaining why IOP with an I/A handpiece was significantly higher than with a phaco handpiece. With the I/A handpiece, vacuum parameters less than 450 mmHg did not result in corneal deformation. IOP with a 3.2‐mm CCI was significantly lower than with a 3.0‐mm CCI, with the 3.2‐mm flow being<abstract abstract-type="main" id="vop12231-abs-0001"> <title>Abstract</title> <sec id="vop12231-sec-0001" sec-type="section"> <title>Objective</title> <p>To optimize fluid dynamics through measuring intraocular pressure (IOP) in a venturi phacoemulsification machine in dogs.</p> </sec> <sec id="vop12231-sec-0002" sec-type="section"> <title>Procedures</title> <p>In step I, flow and IOP of the test chamber were measured using a pressure transducer with the bottle height (BH) set at 50, 70, 100, and 120 cm and the vacuum from 30 to 450 mmHg. A 19‐gauge phaco and a 0.3‐mm irrigation/aspiration (I/A) handpiece were used. In step II, flow and IOP were measured in an enucleated canine eye with a 3.0‐ and a 3.2‐mm clear corneal incision (CCI), respectively. IOP was measured using the pressure transducer at a 30‐mmHg vacuum to allow corneal deformation, to define the fluidic parameters for preventing surge.</p> </sec> <sec id="vop12231-sec-0003" sec-type="section"> <title>Results</title> <p>Flow was directly proportional to the BH and vacuum, whereas IOP was directly proportional to the BH and inversely to the vacuum. Flow with an I/A handpiece was significantly less than with a phaco handpiece, explaining why IOP with an I/A handpiece was significantly higher than with a phaco handpiece. With the I/A handpiece, vacuum parameters less than 450 mmHg did not result in corneal deformation. IOP with a 3.2‐mm CCI was significantly lower than with a 3.0‐mm CCI, with the 3.2‐mm flow being greater than the 3.0‐mm flow.</p> </sec> <sec id="vop12231-sec-0004" sec-type="section"> <title>Conclusions</title> <p> BH during the I/A stage could be reduced to avoid unnecessary stress on the canine eye when using a venturi system. Although phacoemulsification with a 3.2‐mm CCI could induce lower IOP, a 3.0‐mm CCI might lessen the irrigation flow stress on the eye.</p> </sec> </abstract> … (more)
- Is Part Of:
- Veterinary ophthalmology. Volume 18:Number 4(2015)
- Journal:
- Veterinary ophthalmology
- Issue:
- Volume 18:Number 4(2015)
- Issue Display:
- Volume 18, Issue 4 (2015)
- Year:
- 2015
- Volume:
- 18
- Issue:
- 4
- Issue Sort Value:
- 2015-0018-0004-0000
- Page Start:
- 309
- Page End:
- 316
- Publication Date:
- 2014-10-27
- Subjects:
- Veterinary ophthalmology -- Periodicals
636.08977 - Journal URLs:
- http://www.blackwell-synergy.com/member/institutions/issuelist.asp?journal=vop ↗
http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1463-5224 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/vop.12231 ↗
- Languages:
- English
- ISSNs:
- 1463-5216
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 9229.162000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 3648.xml