Sensitivity and Specificity of Automated Detection of Early Repolarization in Standard 12‐Lead Electrocardiography. Issue 4 (4th November 2014)
- Record Type:
- Journal Article
- Title:
- Sensitivity and Specificity of Automated Detection of Early Repolarization in Standard 12‐Lead Electrocardiography. Issue 4 (4th November 2014)
- Main Title:
- Sensitivity and Specificity of Automated Detection of Early Repolarization in Standard 12‐Lead Electrocardiography
- Authors:
- Kenttä, Tuomas
Porthan, Kimmo
Tikkanen, Jani T.
Väänänen, Heikki
Oikarinen, Lasse
Viitasalo, Matti
Karanko, Hannu
Laaksonen, Maarit
Huikuri, Heikki V. - Abstract:
- <abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="anec12226-sec-0010" sec-type="section"> <title>Background</title> <p>Early repolarization (ER) is defined as an elevation of the QRS‐ST junction in at least two inferior or lateral leads of the standard 12‐lead electrocardiogram (ECG). Our purpose was to create an algorithm for the automated detection and classification of ER.</p> </sec> <sec id="anec12226-sec-0020" sec-type="section"> <title>Methods</title> <p>A total of 6, 047 electrocardiograms were manually graded for ER by two experienced readers. The automated detection of ER was based on quantification of the characteristic slurring or notching in ER‐positive leads. The ER detection algorithm was tested and its results were compared with manual grading, which served as the reference.</p> </sec> <sec id="anec12226-sec-0030" sec-type="section"> <title>Results</title> <p>Readers graded 183 ECGs (3.0%) as ER positive, of which the algorithm detected 176 recordings, resulting in sensitivity of 96.2%. Of the 5, 864 ER‐negative recordings, the algorithm classified 5, 281 as negative, resulting in 90.1% specificity. Positive and negative predictive values for the algorithm were 23.2% and 99.9%, respectively, and its accuracy was 90.2%. Inferior ER was correctly detected in 84.6% and lateral ER in 98.6% of the cases.</p> </sec> <sec id="anec12226-sec-0040" sec-type="section"> <title>Conclusions</title> <p>As the automatic algorithm<abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="anec12226-sec-0010" sec-type="section"> <title>Background</title> <p>Early repolarization (ER) is defined as an elevation of the QRS‐ST junction in at least two inferior or lateral leads of the standard 12‐lead electrocardiogram (ECG). Our purpose was to create an algorithm for the automated detection and classification of ER.</p> </sec> <sec id="anec12226-sec-0020" sec-type="section"> <title>Methods</title> <p>A total of 6, 047 electrocardiograms were manually graded for ER by two experienced readers. The automated detection of ER was based on quantification of the characteristic slurring or notching in ER‐positive leads. The ER detection algorithm was tested and its results were compared with manual grading, which served as the reference.</p> </sec> <sec id="anec12226-sec-0030" sec-type="section"> <title>Results</title> <p>Readers graded 183 ECGs (3.0%) as ER positive, of which the algorithm detected 176 recordings, resulting in sensitivity of 96.2%. Of the 5, 864 ER‐negative recordings, the algorithm classified 5, 281 as negative, resulting in 90.1% specificity. Positive and negative predictive values for the algorithm were 23.2% and 99.9%, respectively, and its accuracy was 90.2%. Inferior ER was correctly detected in 84.6% and lateral ER in 98.6% of the cases.</p> </sec> <sec id="anec12226-sec-0040" sec-type="section"> <title>Conclusions</title> <p>As the automatic algorithm has high sensitivity, it could be used as a prescreening tool for ER; only the electrocardiograms graded positive by the algorithm would be reviewed manually. This would reduce the need for manual labor by 90%.</p> </sec> </abstract> … (more)
- Is Part Of:
- Annals of noninvasive electrocardiology. Volume 20:Issue 4(2015)
- Journal:
- Annals of noninvasive electrocardiology
- Issue:
- Volume 20:Issue 4(2015)
- Issue Display:
- Volume 20, Issue 4 (2015)
- Year:
- 2015
- Volume:
- 20
- Issue:
- 4
- Issue Sort Value:
- 2015-0020-0004-0000
- Page Start:
- 355
- Page End:
- 361
- Publication Date:
- 2014-11-04
- Subjects:
- Electrocardiography -- Periodicals
Arrhythmia -- Periodicals
616.1207547 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1542-474X ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/anec.12226 ↗
- Languages:
- English
- ISSNs:
- 1082-720X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 1043.144000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 3470.xml