Effect of repeated firings on flexural strength of veneered zirconia. Issue 8 (August 2015)
- Record Type:
- Journal Article
- Title:
- Effect of repeated firings on flexural strength of veneered zirconia. Issue 8 (August 2015)
- Main Title:
- Effect of repeated firings on flexural strength of veneered zirconia
- Authors:
- Vichi, A.
Sedda, M.
Bonadeo, G.
Bosco, M.
Barbiera, A.
Tsintsadze, N.
Carrabba, M.
Ferrari, M. - Abstract:
- <abstract abstract-type="author" id="abs0005"> <title id="sect0005">Abstract</title> <sec> <title id="sect0010">Objective</title> <p id="spar0005">Chipping and/or delamination represent a clinical failure of porcelain fused to zirconia (PFZ) prostheses. Causes and solutions have not been completely clarified. The present study was aimed at evaluating the effects of number of firings on the flexural strength of PFZ specimen.</p> </sec> <sec> <title id="sect0015">Methods</title> <p id="spar0010">Forty-five zirconia specimens in shape of bars were cut, sintered and divided in 3 groups (<italic>n</italic> = 15). Group 1: veneering ceramic was layered "in bulk" and fired. Group 2: veneering ceramic was layered in three layers, individually fired. Group 3: veneering ceramic was layered in five layers, individually fired. Each layer thickness was controlled by the use of calibrated molds. The total veneering ceramic thickness for all the specimens was 1.2 mm, and the total thickness of the specimen of 2.0 mm. Three-point bending test was performed. Fracture load was recorded in Newton and MPa value was calculated taking into account the bi-layered nature of the specimen. Data were statistically analyzed.</p> </sec> <sec> <title id="sect0020">Results</title> <p id="spar0015">Specimens obtained with on single firing cycle obtained a statistically significant (<italic>p</italic> &lt; 0.001) lower flexural strength (54.61 ± 8.98 MPa) than specimens veneered with 3 or 5 firing cycles.<abstract abstract-type="author" id="abs0005"> <title id="sect0005">Abstract</title> <sec> <title id="sect0010">Objective</title> <p id="spar0005">Chipping and/or delamination represent a clinical failure of porcelain fused to zirconia (PFZ) prostheses. Causes and solutions have not been completely clarified. The present study was aimed at evaluating the effects of number of firings on the flexural strength of PFZ specimen.</p> </sec> <sec> <title id="sect0015">Methods</title> <p id="spar0010">Forty-five zirconia specimens in shape of bars were cut, sintered and divided in 3 groups (<italic>n</italic> = 15). Group 1: veneering ceramic was layered "in bulk" and fired. Group 2: veneering ceramic was layered in three layers, individually fired. Group 3: veneering ceramic was layered in five layers, individually fired. Each layer thickness was controlled by the use of calibrated molds. The total veneering ceramic thickness for all the specimens was 1.2 mm, and the total thickness of the specimen of 2.0 mm. Three-point bending test was performed. Fracture load was recorded in Newton and MPa value was calculated taking into account the bi-layered nature of the specimen. Data were statistically analyzed.</p> </sec> <sec> <title id="sect0020">Results</title> <p id="spar0015">Specimens obtained with on single firing cycle obtained a statistically significant (<italic>p</italic> &lt; 0.001) lower flexural strength (54.61 ± 8.98 MPa) than specimens veneered with 3 or 5 firing cycles. The last two obtained very similar results (77.63 ± 13.17 MPa and 73.62 ± 12.38 MPa respectively) and the differences was not statistically significant.</p> </sec> <sec> <title id="sect0025">Significance</title> <p id="spar0020">In bi-layered PFZ specimen, three to five layers and firings determine higher flexural resistance when compared to a single firing. Thus, a 3-layers veneering procedure is recommended to increase flexural resistance. If a 5-layer procedure is necessary to improve esthetics, it does not decrease flexural resistance.</p> </sec> </abstract> … (more)
- Is Part Of:
- Dental materials. Volume 31:Issue 8(2015)
- Journal:
- Dental materials
- Issue:
- Volume 31:Issue 8(2015)
- Issue Display:
- Volume 31, Issue 8 (2015)
- Year:
- 2015
- Volume:
- 31
- Issue:
- 8
- Issue Sort Value:
- 2015-0031-0008-0000
- Page Start:
- e151
- Page End:
- e156
- Publication Date:
- 2015-08
- Subjects:
- Dentistry -- Periodicals
Dental materials -- Periodicals
617.695 - Journal URLs:
- http://www.elsevier.com/journals ↗
http://www.sciencedirect.com/science/journal/01095641/ ↗ - DOI:
- 10.1016/j.dental.2015.04.012 ↗
- Languages:
- English
- ISSNs:
- 0109-5641
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3553.365800
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 3032.xml