Is Pupil Diameter Influenced by Refractive Error?. Issue 7 (July 2015)
- Record Type:
- Journal Article
- Title:
- Is Pupil Diameter Influenced by Refractive Error?. Issue 7 (July 2015)
- Main Title:
- Is Pupil Diameter Influenced by Refractive Error?
- Authors:
- Orr, Janis B.
Seidel, Dirk
Day, Mhairi
Gray, Lyle S. - Abstract:
- <abstract> <title>ABSTRACT</title> <sec> <title>Purpose</title> <p>To investigate the relationship between pupil diameter and refractive error and how refractive correction, target luminance, and accommodation modulate this relationship.</p> </sec> <sec> <title>Methods</title> <p>Sixty emmetropic, myopic, and hyperopic subjects (age range, 18 to 35 years) viewed an illuminated target (luminance: 10, 100, 200, 400, 1000, 2000, and 4100 cd/m<sup>2</sup>) within a Badal optical system, at 0 diopters (D) and −3 D vergence, with and without refractive correction. Refractive error was corrected using daily disposable contact lenses. Pupil diameter and accommodation were recorded continuously using a commercially available photorefractor.</p> </sec> <sec> <title>Results</title> <p>No significant difference in pupil diameter was found between the refractive groups at 0 D or −3 D target vergence, in the corrected or uncorrected conditions. As expected, pupil diameter decreased with increasing luminance. Target vergence had no significant influence on pupil diameter. In the corrected condition, at 0 D target vergence, the accommodation response was similar in all refractive groups. At −3 D target vergence, the emmetropic and myopic groups accommodated significantly more than the hyperopic group at all luminance levels. There was no correlation between accommodation response and pupil diameter or refractive error in any refractive group. In the uncorrected condition, the accommodation<abstract> <title>ABSTRACT</title> <sec> <title>Purpose</title> <p>To investigate the relationship between pupil diameter and refractive error and how refractive correction, target luminance, and accommodation modulate this relationship.</p> </sec> <sec> <title>Methods</title> <p>Sixty emmetropic, myopic, and hyperopic subjects (age range, 18 to 35 years) viewed an illuminated target (luminance: 10, 100, 200, 400, 1000, 2000, and 4100 cd/m<sup>2</sup>) within a Badal optical system, at 0 diopters (D) and −3 D vergence, with and without refractive correction. Refractive error was corrected using daily disposable contact lenses. Pupil diameter and accommodation were recorded continuously using a commercially available photorefractor.</p> </sec> <sec> <title>Results</title> <p>No significant difference in pupil diameter was found between the refractive groups at 0 D or −3 D target vergence, in the corrected or uncorrected conditions. As expected, pupil diameter decreased with increasing luminance. Target vergence had no significant influence on pupil diameter. In the corrected condition, at 0 D target vergence, the accommodation response was similar in all refractive groups. At −3 D target vergence, the emmetropic and myopic groups accommodated significantly more than the hyperopic group at all luminance levels. There was no correlation between accommodation response and pupil diameter or refractive error in any refractive group. In the uncorrected condition, the accommodation response was significantly greater in the hyperopic group than in the myopic group at all luminance levels, particularly for near viewing. In the hyperopic group, the accommodation response was significantly correlated with refractive error but not pupil diameter. In the myopic group, accommodation response level was not correlated with refractive error or pupil diameter.</p> </sec> <sec> <title>Conclusions</title> <p>Refractive error has no influence on pupil diameter, irrespective of refractive correction or accommodative demand. This suggests that the pupil is controlled by the pupillary light reflex and is not driven by retinal blur.</p> </sec> </abstract> … (more)
- Is Part Of:
- Optometry and vision science. Volume 92:Issue 7(2015)
- Journal:
- Optometry and vision science
- Issue:
- Volume 92:Issue 7(2015)
- Issue Display:
- Volume 92, Issue 7 (2015)
- Year:
- 2015
- Volume:
- 92
- Issue:
- 7
- Issue Sort Value:
- 2015-0092-0007-0000
- Page Start:
- Page End:
- Publication Date:
- 2015-07
- Subjects:
- Optometry -- Periodicals
Physiological optics -- Periodicals
Vision disorders -- Periodicals
617.7505 - Journal URLs:
- http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&PAGE=toc&D=ovft&AN=00006324-000000000-00000 ↗
http://www.optvissci.com ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/OPX.0000000000000627 ↗
- Languages:
- English
- ISSNs:
- 1040-5488
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6276.450000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 4096.xml