In Vitro Spoilation of Silicone-Hydrogel Soft Contact Lenses in a Model-Blink Cell. Issue 7 (July 2015)
- Record Type:
- Journal Article
- Title:
- In Vitro Spoilation of Silicone-Hydrogel Soft Contact Lenses in a Model-Blink Cell. Issue 7 (July 2015)
- Main Title:
- In Vitro Spoilation of Silicone-Hydrogel Soft Contact Lenses in a Model-Blink Cell
- Authors:
- Peng, Cheng-Chun
Fajardo, Neil P.
Razunguzwa, Trust
Radke, Clayton J. - Abstract:
- <abstract> <title>ABSTRACT</title> <sec> <title>Purpose</title> <p>We developed an <italic>in vitro</italic> model-blink cell that reproduces the mechanism of <italic>in vivo</italic> fouling of soft contact lenses. In the model-blink cell, model tear lipid directly contacts the lens surface after forced aqueous rupture, mirroring the pre–lens tear-film breakup during interblink.</p> </sec> <sec> <title>Methods</title> <p>Soft contact lenses are attached to a Teflon holder and immersed in artificial tear solution with protein, salts, and mucins. Artificial tear-lipid solution is spread over the air/tear interface as a duplex lipid layer. The aqueous tear film is periodically ruptured and reformed by withdrawing and reinjecting tear solution into the cell, mimicking the blink-rupture process. Fouled deposits appear on the lenses after cycling, and their compositions and spatial distributions are subsequently analyzed by optical microscopy, laser ablation electrospray ionization mass spectrometry, and two-photon fluorescence confocal scanning laser microscopy.</p> </sec> <sec> <title>Results</title> <p>Discrete deposit (white) spots with an average size of 20 to 300 μm are observed on the studied lenses, confirming what is seen <italic>in vivo</italic> and validating the <italic>in vitro</italic> model-blink cell. Targeted lipids (cholesterol) and proteins (albumin from bovine serum) are identified in the discrete surface deposits. Both lipid and protein occur simultaneously<abstract> <title>ABSTRACT</title> <sec> <title>Purpose</title> <p>We developed an <italic>in vitro</italic> model-blink cell that reproduces the mechanism of <italic>in vivo</italic> fouling of soft contact lenses. In the model-blink cell, model tear lipid directly contacts the lens surface after forced aqueous rupture, mirroring the pre–lens tear-film breakup during interblink.</p> </sec> <sec> <title>Methods</title> <p>Soft contact lenses are attached to a Teflon holder and immersed in artificial tear solution with protein, salts, and mucins. Artificial tear-lipid solution is spread over the air/tear interface as a duplex lipid layer. The aqueous tear film is periodically ruptured and reformed by withdrawing and reinjecting tear solution into the cell, mimicking the blink-rupture process. Fouled deposits appear on the lenses after cycling, and their compositions and spatial distributions are subsequently analyzed by optical microscopy, laser ablation electrospray ionization mass spectrometry, and two-photon fluorescence confocal scanning laser microscopy.</p> </sec> <sec> <title>Results</title> <p>Discrete deposit (white) spots with an average size of 20 to 300 μm are observed on the studied lenses, confirming what is seen <italic>in vivo</italic> and validating the <italic>in vitro</italic> model-blink cell. Targeted lipids (cholesterol) and proteins (albumin from bovine serum) are identified in the discrete surface deposits. Both lipid and protein occur simultaneously in the surface deposits and overlap with the white spots observed by optical microscopy. Additionally, lipid and protein penetrate into the bulk of tested silicone-hydrogel lenses, likely attributed to the bicontinuous microstructure of oleophilic silicone and hydrophilic polymer phases of the lens.</p> </sec> <sec> <title>Conclusions</title> <p> <italic>In vitro</italic> spoilation of soft contact lenses is successfully achieved by the model-blink cell confirming the tear rupture/deposition mechanism of lens fouling. The model-blink cell provides a reliable laboratory tool for screening new antifouling lens materials, surface coatings, and care solutions.</p> </sec> </abstract> … (more)
- Is Part Of:
- Optometry and vision science. Volume 92:Issue 7(2015)
- Journal:
- Optometry and vision science
- Issue:
- Volume 92:Issue 7(2015)
- Issue Display:
- Volume 92, Issue 7 (2015)
- Year:
- 2015
- Volume:
- 92
- Issue:
- 7
- Issue Sort Value:
- 2015-0092-0007-0000
- Page Start:
- Page End:
- Publication Date:
- 2015-07
- Subjects:
- Optometry -- Periodicals
Physiological optics -- Periodicals
Vision disorders -- Periodicals
617.7505 - Journal URLs:
- http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&PAGE=toc&D=ovft&AN=00006324-000000000-00000 ↗
http://www.optvissci.com ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/OPX.0000000000000625 ↗
- Languages:
- English
- ISSNs:
- 1040-5488
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6276.450000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 4096.xml