Percutaneous Aortic Balloon Valvuloplasty and Intracardiac Adrenaline in Electromechanical Dissociation as Bridge to Transcatheter Aortic Valve Implantation. Issue 26 (July 2015)
- Record Type:
- Journal Article
- Title:
- Percutaneous Aortic Balloon Valvuloplasty and Intracardiac Adrenaline in Electromechanical Dissociation as Bridge to Transcatheter Aortic Valve Implantation. Issue 26 (July 2015)
- Main Title:
- Percutaneous Aortic Balloon Valvuloplasty and Intracardiac Adrenaline in Electromechanical Dissociation as Bridge to Transcatheter Aortic Valve Implantation
- Authors:
- Chaara, Jawad
Meier, Pascal
Ellenberger, Christophe
Gasche, Yvan
Bendjelid, Karim
Noble, Stephane
Roffi, Marco
Lymperopoulos., Anastasios - Abstract:
- <abstract> <title> <x xml:space="preserve">Abstract</x> </title> <sec> <title>Abstract</title> <p>This report describes an emergent balloon aortic valvuloplasty (BAV) procedure performed under cardiopulmonary resuscitation in a 79-year-old man with severe symptomatic aortic stenosis (mean gradient 78 mm Hg, valve area 0.71 cm<sup>2</sup>, and left ventricular ejection fraction 40%) awaiting surgery and who was admitted for heart failure rapidly evolving to cardiogenic shock and multiorgan failure. Decision was made to perform emergent BAV. After crossing the valve with a 6 French catheter, the patient developed an electromechanical dissociation confirmed at transesophageal echocardiography and cardiac arrest. Manual chest compressions were initiated along with the application of high doses of intravenous adrenaline, and BAV was performed under ongoing resuscitation. Despite BAV, transoesophageal echocardiography demonstrated no cardiac activity. At this point, it was decided to advance a pigtail catheter over the wire already in place in the left ventricle and to inject intracardiac adrenaline (1 mg, followed by 5 mg). Left ventricular contraction progressively resumed and, in the absence of aortic regurgitation, an intraaortic balloon pump was inserted. The patient could be weaned from intraaortic balloon pump and vasopressors on day 1, extubated on day 6, and recovered from multiorgan failure. In the absence of neurologic deficits, he underwent uneventful transcatheter<abstract> <title> <x xml:space="preserve">Abstract</x> </title> <sec> <title>Abstract</title> <p>This report describes an emergent balloon aortic valvuloplasty (BAV) procedure performed under cardiopulmonary resuscitation in a 79-year-old man with severe symptomatic aortic stenosis (mean gradient 78 mm Hg, valve area 0.71 cm<sup>2</sup>, and left ventricular ejection fraction 40%) awaiting surgery and who was admitted for heart failure rapidly evolving to cardiogenic shock and multiorgan failure. Decision was made to perform emergent BAV. After crossing the valve with a 6 French catheter, the patient developed an electromechanical dissociation confirmed at transesophageal echocardiography and cardiac arrest. Manual chest compressions were initiated along with the application of high doses of intravenous adrenaline, and BAV was performed under ongoing resuscitation. Despite BAV, transoesophageal echocardiography demonstrated no cardiac activity. At this point, it was decided to advance a pigtail catheter over the wire already in place in the left ventricle and to inject intracardiac adrenaline (1 mg, followed by 5 mg). Left ventricular contraction progressively resumed and, in the absence of aortic regurgitation, an intraaortic balloon pump was inserted. The patient could be weaned from intraaortic balloon pump and vasopressors on day 1, extubated on day 6, and recovered from multiorgan failure. In the absence of neurologic deficits, he underwent uneventful transcatheter aortic valve implantation on day 12 and was discharged to a cardiac rehabilitation program on day 30. At 3-month follow-up, he reported dyspnea NYHA class II as the only symptom.</p> <p>This case shows that severe aortic stenosis leading to electromechanical dissociation may be treated by emergent BAV and intracardiac administration of high-dose adrenaline. Intracardiac adrenaline may be considered in case of refractory electromechanical dissociation occurring in the cardiac catheterization laboratory.</p> </sec> </abstract> … (more)
- Is Part Of:
- Medicine. Volume 94:Issue 26(2015)
- Journal:
- Medicine
- Issue:
- Volume 94:Issue 26(2015)
- Issue Display:
- Volume 94, Issue 26 (2015)
- Year:
- 2015
- Volume:
- 94
- Issue:
- 26
- Issue Sort Value:
- 2015-0094-0026-0000
- Page Start:
- Page End:
- Publication Date:
- 2015-07
- Subjects:
- Medicine -- Periodicals
Medicine -- Periodicals
Médecine -- Périodiques
Geneeskunde
Medicine
Periodicals
Periodicals
610.5 - Journal URLs:
- http://journals.lww.com/md-journal/pages/default.aspx ↗
http://gateway.ovid.com/ovidweb.cgi?T=JS&PAGE=toc&D=ovft&MODE=ovid&NEWS=N&AN=00002060-000000000-00000 ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/MD.0000000000001061 ↗
- Languages:
- English
- ISSNs:
- 0025-7974
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5534.000000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 3550.xml