Re‐evaluation of Pre‐pump Arterial Pressure to Avoid Inadequate Dialysis and Hemolysis: Importance of Prepump Arterial Pressure Monitoring in Hemodialysis Patients. Issue 7 (1st May 2015)
- Record Type:
- Journal Article
- Title:
- Re‐evaluation of Pre‐pump Arterial Pressure to Avoid Inadequate Dialysis and Hemolysis: Importance of Prepump Arterial Pressure Monitoring in Hemodialysis Patients. Issue 7 (1st May 2015)
- Main Title:
- Re‐evaluation of Pre‐pump Arterial Pressure to Avoid Inadequate Dialysis and Hemolysis: Importance of Prepump Arterial Pressure Monitoring in Hemodialysis Patients
- Authors:
- Shibata, Eriko
Nagai, Kojiro
Takeuchi, Risa
Noda, Yasuhiro
Makino, Tomomi
Chikata, Yusuke
Hann, Michael
Yoshimoto, Sakiya
Ono, Hiroyuki
Ueda, Sayo
Tamaki, Masanori
Murakami, Taichi
Matsuura, Motokazu
Abe, Hideharu
Doi, Toshio - Abstract:
- <abstract abstract-type="main"> <title>Abstract</title> <p>Prepump arterial pressure (PreAP) is monitored to avoid generating excessive negative pressure. The National Kidney Foundation K/DOQI clinical practice guidelines for vascular access recommend that PreAP should not fall below −250 mm Hg because excessive negative PreAP can lead to a decrease in the delivery of blood flow, inadequate dialysis, and hemolysis. Nonetheless, these recommendations are consistently disregarded in clinical practice and pressure sensors are often removed from the dialysis circuit. Thus far, delivered blood flow has been reported to decrease at values more negative than −150 mm Hg of PreAP. These values have been analyzed by an ultrasonic flowmeter and not directly measured. Furthermore, no known group has evaluated whether PreAP‐induced hemolysis occurs at a particular threshold. Therefore, the aim of this study was to clarify the importance of PreAP in the prediction of inadequate dialysis and hemolysis. By using different diameter needles, human blood samples from healthy volunteers were circulated in a closed dialysis circuit. The relationship between PreAP and delivered blood flow or PreAP and hemolysis was investigated. We also investigated the optimal value for PreAP using several empirical monitoring methods, such as a pressure pillow. Our investigation indicated that PreAP is a critical factor in the determination of delivered blood flow and hemolysis, both of which occured at<abstract abstract-type="main"> <title>Abstract</title> <p>Prepump arterial pressure (PreAP) is monitored to avoid generating excessive negative pressure. The National Kidney Foundation K/DOQI clinical practice guidelines for vascular access recommend that PreAP should not fall below −250 mm Hg because excessive negative PreAP can lead to a decrease in the delivery of blood flow, inadequate dialysis, and hemolysis. Nonetheless, these recommendations are consistently disregarded in clinical practice and pressure sensors are often removed from the dialysis circuit. Thus far, delivered blood flow has been reported to decrease at values more negative than −150 mm Hg of PreAP. These values have been analyzed by an ultrasonic flowmeter and not directly measured. Furthermore, no known group has evaluated whether PreAP‐induced hemolysis occurs at a particular threshold. Therefore, the aim of this study was to clarify the importance of PreAP in the prediction of inadequate dialysis and hemolysis. By using different diameter needles, human blood samples from healthy volunteers were circulated in a closed dialysis circuit. The relationship between PreAP and delivered blood flow or PreAP and hemolysis was investigated. We also investigated the optimal value for PreAP using several empirical monitoring methods, such as a pressure pillow. Our investigation indicated that PreAP is a critical factor in the determination of delivered blood flow and hemolysis, both of which occured at pressure values more negative than −150 mm Hg. With the exception of direct pressure monitoring, commonly used monitoring methods for PreAP were determined to be ineffective. We propose that the use of a vacuum monitor would permit regular measurement of PreAP.</p> </abstract> … (more)
- Is Part Of:
- Artificial organs. Volume 39:Issue 7(2015:Jul.)
- Journal:
- Artificial organs
- Issue:
- Volume 39:Issue 7(2015:Jul.)
- Issue Display:
- Volume 39, Issue 7 (2015)
- Year:
- 2015
- Volume:
- 39
- Issue:
- 7
- Issue Sort Value:
- 2015-0039-0007-0000
- Page Start:
- 627
- Page End:
- 634
- Publication Date:
- 2015-05-01
- Subjects:
- Artificial organs -- Periodicals
617.956 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1525-1594 ↗
http://www.blackwell-synergy.com/member/institutions/issuelist.asp?journal=aor ↗
http://onlinelibrary.wiley.com/ ↗
http://firstsearch.oclc.org ↗ - DOI:
- 10.1111/aor.12448 ↗
- Languages:
- English
- ISSNs:
- 0160-564X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 1735.052000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 3225.xml