Early diagnostic and prognostic utility of high‐sensitive troponin assays in acute myocardial infarction: a meta‐analysis. Issue 7 (July 2015)
- Record Type:
- Journal Article
- Title:
- Early diagnostic and prognostic utility of high‐sensitive troponin assays in acute myocardial infarction: a meta‐analysis. Issue 7 (July 2015)
- Main Title:
- Early diagnostic and prognostic utility of high‐sensitive troponin assays in acute myocardial infarction: a meta‐analysis
- Authors:
- Li, W.‐J.
Chen, X.‐M.
Nie, X.‐Y.
Lin, X.‐X.
Cheng, Y.‐J.
Hu, C.‐H.
Du, Z.‐M.
Dong, Y.‐G.
Ma, H.
Wu, S.‐H. - Abstract:
- <abstract abstract-type="main"> <title>Abstract</title> <sec id="imj12642-sec-0001" sec-type="section"> <title>Background/Aim</title> <p>To determine the diagnostic and prognostic utility of high‐sensitive troponin assays in the very early phase of acute myocardial infarction (AMI) (less than 3 h since symptoms onset) by performing a meta‐analysis of prospective studies.</p> </sec> <sec id="imj12642-sec-0002" sec-type="section"> <title>Methods</title> <p>Relevant studies were identified by searches of MEDLINE and Elsevier Sciencedirect until 31 January 2014 and by reviewing the reference lists from retrieved articles. Prospective studies that reported diagnostic utility in AMI using both high‐sensitive troponin assays and conventional cardiac troponin, and reported the estimates of hazard ratio (HR) with 95% confidence intervals (CI) for prognostic utility were included. Data were extracted independently by two authors and summary estimates of association were obtained using a random effects model.</p> </sec> <sec id="imj12642-sec-0005" sec-type="section"> <title>Results</title> <p>Of the seven studies included, four studies reported the diagnostic utility of high‐sensitive troponin assays (2863 patients) and three reported the prognostic utility in AMI (2329 patients). Within 12 h of symptoms onset, the pooled sensitivity and specificity of high‐sensitive troponin assays were 0.89 (95% CI 0.85–0.91) and 0.89 (95% CI 0.85–0.92), respectively, and within 3 h, the pooled<abstract abstract-type="main"> <title>Abstract</title> <sec id="imj12642-sec-0001" sec-type="section"> <title>Background/Aim</title> <p>To determine the diagnostic and prognostic utility of high‐sensitive troponin assays in the very early phase of acute myocardial infarction (AMI) (less than 3 h since symptoms onset) by performing a meta‐analysis of prospective studies.</p> </sec> <sec id="imj12642-sec-0002" sec-type="section"> <title>Methods</title> <p>Relevant studies were identified by searches of MEDLINE and Elsevier Sciencedirect until 31 January 2014 and by reviewing the reference lists from retrieved articles. Prospective studies that reported diagnostic utility in AMI using both high‐sensitive troponin assays and conventional cardiac troponin, and reported the estimates of hazard ratio (HR) with 95% confidence intervals (CI) for prognostic utility were included. Data were extracted independently by two authors and summary estimates of association were obtained using a random effects model.</p> </sec> <sec id="imj12642-sec-0005" sec-type="section"> <title>Results</title> <p>Of the seven studies included, four studies reported the diagnostic utility of high‐sensitive troponin assays (2863 patients) and three reported the prognostic utility in AMI (2329 patients). Within 12 h of symptoms onset, the pooled sensitivity and specificity of high‐sensitive troponin assays were 0.89 (95% CI 0.85–0.91) and 0.89 (95% CI 0.85–0.92), respectively, and within 3 h, the pooled sensitivity and specificity of high‐sensitive troponin assays were 0.79 (95% CI 0.71–0.85) and 0.92 (95% CI 0.88–0.96) respectively. Compared with conventional cardiac troponin assays, the high‐sensitive troponin assays had higher sensitivity (0.89 vs 0.72) but lower specificity (0.89 vs 0.95) in diagnosing AMI within 12 h of symptoms onset. Within 3 h, the sensitivity of high‐sensitive troponin assays was still higher (0.79 vs 0.59), but the specificity was almost the same (0.92 vs 0.95) as that of conventional troponin assays. The elevated high‐sensitive troponin assays had an overall pooled HR of 2.66 (95% CI 1.31–5.44) and 2.14 (95% CI 1.15–3.98) for the end‐points of death and non‐fatal AMI respectively.</p> </sec> <sec id="imj12642-sec-0006" sec-type="section"> <title>Conclusions</title> <p>These findings provide quantitative data supporting high‐sensitive troponin assays having early diagnostic and prognostic utility in AMI.</p> </sec> </abstract> … (more)
- Is Part Of:
- Internal medicine journal. Volume 45:Issue 7(2015)
- Journal:
- Internal medicine journal
- Issue:
- Volume 45:Issue 7(2015)
- Issue Display:
- Volume 45, Issue 7 (2015)
- Year:
- 2015
- Volume:
- 45
- Issue:
- 7
- Issue Sort Value:
- 2015-0045-0007-0000
- Page Start:
- 748
- Page End:
- 756
- Publication Date:
- 2015-07
- Subjects:
- Medicine -- Periodicals
616 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1111/imj.12642 ↗
- Languages:
- English
- ISSNs:
- 1444-0903
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4534.905200
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 3425.xml