Continuous blood pressure measurement using the pulse transit time: Comparison to intra-arterial measurement. (August 2015)
- Record Type:
- Journal Article
- Title:
- Continuous blood pressure measurement using the pulse transit time: Comparison to intra-arterial measurement. (August 2015)
- Main Title:
- Continuous blood pressure measurement using the pulse transit time: Comparison to intra-arterial measurement
- Authors:
- Patzak, Andreas
Mendoza, Yuri
Gesche, Heiko
Konermann, Martin - Abstract:
- <abstract> <title>Abstract</title> <p>Continuous blood pressure (BP) measurement allows the investigation of transient changes in BP and thus may give insights into mechanisms of BP control. We validated a continuous, non-invasive BP measurement based on the pulse transit time (PTT), i.e. BP<sub>PTT</sub>, by comparing it with the intra-arterial BP (BP<sub>i.a.</sub>) measurement. Twelve subjects (five females and seven males) were included. BP<sub>i.a.</sub> was obtained from the radial artery using a system from ReCor Medical. Systolic and diastolic BP were calculated using the PTT (BP<sub>PTT</sub>, SOMNOscreen<sup>™</sup>). PTT was determined from the electrocardiogram and the peripheral pulse wave. The BP was modulated by application of increasing doses of dobutamine (5, 10, 20 μg/kg body mass). Systolic BP<sub>PTT</sub> and systolic BP<sub>i.a.</sub> correlated significantly (<italic>R</italic> = 0.94). The limits of agreement in the Bland—Altman plot were ± 19 mmHg; the mean values differed by 1 mmHg. The correlation coefficient for the diastolic BP measurements was <italic>R</italic> = 0.42. The limits of agreement in the Bland—Altman plot were ± 18 mmHg, with a mean difference of 5 mmHg in favour of the BP<sub>PTT</sub>. The study demonstrates a significant correlation between the measurement methods for systolic BP. The results encourage the application of PTT-based BP measurement for the evaluation of BP dynamics and pathological BP changes.</p> </abstract>
- Is Part Of:
- Blood pressure. Volume 24:Number 4(2015)
- Journal:
- Blood pressure
- Issue:
- Volume 24:Number 4(2015)
- Issue Display:
- Volume 24, Issue 4 (2015)
- Year:
- 2015
- Volume:
- 24
- Issue:
- 4
- Issue Sort Value:
- 2015-0024-0004-0000
- Page Start:
- 217
- Page End:
- 221
- Publication Date:
- 2015-08
- Subjects:
- Blood pressure -- Periodicals
Hypertension -- Periodicals
Hypertension -- Periodicals
Blood Pressure -- Periodicals
612.14 - Journal URLs:
- http://informahealthcare.com/loi/blo ↗
http://www.tandf.co.uk/journals/titles/08037051.asp ↗
http://informahealthcare.com ↗ - DOI:
- 10.3109/08037051.2015.1030901 ↗
- Languages:
- English
- ISSNs:
- 0803-7051
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 2113.034000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 3833.xml