Mechanical Testing of a Synthetic Canine Gastrocnemius Tendon Implant. Issue 5 (July 2015)
- Record Type:
- Journal Article
- Title:
- Mechanical Testing of a Synthetic Canine Gastrocnemius Tendon Implant. Issue 5 (July 2015)
- Main Title:
- Mechanical Testing of a Synthetic Canine Gastrocnemius Tendon Implant
- Authors:
- Morton, Mark A.
Whitelock, Richard G.
Innes, John F. - Abstract:
- <abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="vsu12329-sec-0001" sec-type="section"> <title>Objective</title> <p>To test a polyethylene terephthalate prosthesis (STIF, Chenove, France) for gastrocnemius tendon repair in dogs (cadaver model).</p> </sec> <sec id="vsu12329-sec-0002" sec-type="section"> <title>Study Design</title> <p>In vitro mechanical study.</p> </sec> <sec id="vsu12329-sec-0003" sec-type="section"> <title>Animals</title> <p>Pelvic limbs (n = 8) from 4 recently euthanatized adult dogs (weighing 30–45 kg).</p> </sec> <sec id="vsu12329-sec-0004" sec-type="section"> <title>Methods</title> <p>Proximally the implant was sutured at the myotendinous junction of the gastrocnemius and distally secured in a 4.5 mm blind ending tunnel in the medullary cavity of the calcaneus using an interference screw (STIF, Chenove, France). Proximal and distal fixation were tested independently using an electrodynamic testing machine (Electropuls 3000, Instron, UK).</p> </sec> <sec id="vsu12329-sec-0005" sec-type="section"> <title>Results</title> <p>Mean ± SD failure loads for the proximal fixation (266.13 ± 43.88 N) was significantly less than for the distal fixation (649.25 ± 210.36 N; <italic>P</italic> = <monospace>.</monospace>042, paired <italic>t</italic>‐test). Mean stiffness of the proximal and distal constructs were 19.08 ± 8.16 N/mm and 139.76 ± 24.51 N/mm, respectively.</p> </sec> <sec id="vsu12329-sec-0006"<abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="vsu12329-sec-0001" sec-type="section"> <title>Objective</title> <p>To test a polyethylene terephthalate prosthesis (STIF, Chenove, France) for gastrocnemius tendon repair in dogs (cadaver model).</p> </sec> <sec id="vsu12329-sec-0002" sec-type="section"> <title>Study Design</title> <p>In vitro mechanical study.</p> </sec> <sec id="vsu12329-sec-0003" sec-type="section"> <title>Animals</title> <p>Pelvic limbs (n = 8) from 4 recently euthanatized adult dogs (weighing 30–45 kg).</p> </sec> <sec id="vsu12329-sec-0004" sec-type="section"> <title>Methods</title> <p>Proximally the implant was sutured at the myotendinous junction of the gastrocnemius and distally secured in a 4.5 mm blind ending tunnel in the medullary cavity of the calcaneus using an interference screw (STIF, Chenove, France). Proximal and distal fixation were tested independently using an electrodynamic testing machine (Electropuls 3000, Instron, UK).</p> </sec> <sec id="vsu12329-sec-0005" sec-type="section"> <title>Results</title> <p>Mean ± SD failure loads for the proximal fixation (266.13 ± 43.88 N) was significantly less than for the distal fixation (649.25 ± 210.36 N; <italic>P</italic> = <monospace>.</monospace>042, paired <italic>t</italic>‐test). Mean stiffness of the proximal and distal constructs were 19.08 ± 8.16 N/mm and 139.76 ± 24.51 N/mm, respectively.</p> </sec> <sec id="vsu12329-sec-0006" sec-type="section"> <title>Conclusions</title> <p>Failure loads exceeded the values reported after experimental repair of chronic gastrocnemius tendon injuries using other methods involving suturing tendon to bone. Failure of this repair method clinically is predicted to occur proximally at the level of the myotendinous junction.</p> </sec> </abstract> … (more)
- Is Part Of:
- Veterinary surgery. Volume 44:Issue 5(2015)
- Journal:
- Veterinary surgery
- Issue:
- Volume 44:Issue 5(2015)
- Issue Display:
- Volume 44, Issue 5 (2015)
- Year:
- 2015
- Volume:
- 44
- Issue:
- 5
- Issue Sort Value:
- 2015-0044-0005-0000
- Page Start:
- 596
- Page End:
- 602
- Publication Date:
- 2015-07
- Subjects:
- Veterinary surgery -- Periodicals
Veterinary Medicine -- Periodicals
Surgery -- Periodicals
Societies, Medical -- Periodicals
636.0897 - Journal URLs:
- http://www.blackwell-synergy.com/loi/vsu ↗
http://www.blackwell-synergy.com/servlet/useragent?func=showIssues&code=vsu ↗
http://www.harcourthealth.com/vetsurg ↗
http://onlinelibrary.wiley.com/ ↗
http://firstsearch.oclc.org ↗
http://firstsearch.oclc.org/journal=0161-3499;screen=info;ECOIP ↗ - DOI:
- 10.1111/j.1532-950X.2015.12329.x ↗
- Languages:
- English
- ISSNs:
- 0161-3499
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 9231.037000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 3234.xml