Accuracy of predicted refraction with multifocal intraocular lenses using two biometry measurement devices and multiple intraocular lens power calculation formulas. (14th January 2015)
- Record Type:
- Journal Article
- Title:
- Accuracy of predicted refraction with multifocal intraocular lenses using two biometry measurement devices and multiple intraocular lens power calculation formulas. (14th January 2015)
- Main Title:
- Accuracy of predicted refraction with multifocal intraocular lenses using two biometry measurement devices and multiple intraocular lens power calculation formulas
- Authors:
- Reitblat, Olga
Assia, Ehud I
Kleinmann, Guy
Levy, Adi
Barrett, Graham D
Abulafia, Adi - Abstract:
- <abstract abstract-type="main"> <title>Abstract</title> <sec id="ceo12478-sec-0001" sec-type="section"> <title>Background</title> <p>To evaluate the accuracy of predicted refraction using multifocal intraocular lenses (IOLs) with power calculation based on two biometric devices and multiple IOL power calculation formulas.</p> </sec> <sec id="ceo12478-sec-0002" sec-type="section"> <title>Design</title> <p>A retrospective study conducted in a private practice ophthalmology clinic.</p> </sec> <sec id="ceo12478-sec-0003" sec-type="section"> <title>Participants</title> <p>Seventy‐three eyes of 48 patients were evaluated.</p> </sec> <sec id="ceo12478-sec-0004" sec-type="section"> <title>Methods</title> <p>Consecutive cases of eyes that had undergone successful cataract surgery with an implantation of a multifocal IOL (SN6AD1, Alcon Laboratories, Inc., Fort Worth, TX, USA) by a single surgeon were enrolled. Patients were meticulously screened for suitability for a multifocal IOL implantation according to our clinic guidelines. Two biometric measurement devices (IOLMaster‐500 [Carl Zeiss Meditec AG, Jena, Germany] and Lenstar‐LS900 [Haag‐Streit AG, Koeniz, Switzerland]) were used under strict validation criteria to evaluate the predicted refraction errors for the Holladay 1, SRK/T, Hoffer Q, Haigis, Holladay 2, Barrett Universal II and Olsen formulas.</p> </sec> <sec id="ceo12478-sec-0005" sec-type="section"> <title>Main Outcome Measures</title> <p>Predicted refractive sphere<abstract abstract-type="main"> <title>Abstract</title> <sec id="ceo12478-sec-0001" sec-type="section"> <title>Background</title> <p>To evaluate the accuracy of predicted refraction using multifocal intraocular lenses (IOLs) with power calculation based on two biometric devices and multiple IOL power calculation formulas.</p> </sec> <sec id="ceo12478-sec-0002" sec-type="section"> <title>Design</title> <p>A retrospective study conducted in a private practice ophthalmology clinic.</p> </sec> <sec id="ceo12478-sec-0003" sec-type="section"> <title>Participants</title> <p>Seventy‐three eyes of 48 patients were evaluated.</p> </sec> <sec id="ceo12478-sec-0004" sec-type="section"> <title>Methods</title> <p>Consecutive cases of eyes that had undergone successful cataract surgery with an implantation of a multifocal IOL (SN6AD1, Alcon Laboratories, Inc., Fort Worth, TX, USA) by a single surgeon were enrolled. Patients were meticulously screened for suitability for a multifocal IOL implantation according to our clinic guidelines. Two biometric measurement devices (IOLMaster‐500 [Carl Zeiss Meditec AG, Jena, Germany] and Lenstar‐LS900 [Haag‐Streit AG, Koeniz, Switzerland]) were used under strict validation criteria to evaluate the predicted refraction errors for the Holladay 1, SRK/T, Hoffer Q, Haigis, Holladay 2, Barrett Universal II and Olsen formulas.</p> </sec> <sec id="ceo12478-sec-0005" sec-type="section"> <title>Main Outcome Measures</title> <p>Predicted refractive sphere equivalent (RSE) errors.</p> </sec> <sec id="ceo12478-sec-0006" sec-type="section"> <title>Results</title> <p>The measurements obtained from the two biometric devices were highly correlated. The standard deviation of the error in predicted RSE and the median absolute error were similar for the IOLMaster and the Lenstar devices using all formulas, ranging from 0.27 dioptres (D) to 0.31D and from 0.15D to 0.21D, respectively. A high percentage of eyes had an error in predicted RSE within ±0.5D from target refraction, ranging from 86.3% to 93.2%.</p> </sec> <sec id="ceo12478-sec-0007" sec-type="section"> <title>Conclusions</title> <p>High accuracy can be achieved in multifocal IOL power calculations by appropriate patient selection, precise biometry and appropriate IOL calculation formulas.</p> </sec> </abstract> … (more)
- Is Part Of:
- Clinical & experimental ophthalmology. Volume 43:Number 4(2015)
- Journal:
- Clinical & experimental ophthalmology
- Issue:
- Volume 43:Number 4(2015)
- Issue Display:
- Volume 43, Issue 4 (2015)
- Year:
- 2015
- Volume:
- 43
- Issue:
- 4
- Issue Sort Value:
- 2015-0043-0004-0000
- Page Start:
- 328
- Page End:
- 334
- Publication Date:
- 2015-01-14
- Subjects:
- Ophthalmology -- Periodicals
617.7 - Journal URLs:
- http://www.blackwellpublishing.com/journal.asp?ref=1442-6404&site=1 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/ceo.12478 ↗
- Languages:
- English
- ISSNs:
- 1442-6404
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.251920
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 4139.xml