Effect of different dental articulating papers on SEMG activity during maximum clenching. Issue 4 (August 2015)
- Record Type:
- Journal Article
- Title:
- Effect of different dental articulating papers on SEMG activity during maximum clenching. Issue 4 (August 2015)
- Main Title:
- Effect of different dental articulating papers on SEMG activity during maximum clenching
- Authors:
- Augusti, Davide
Augusti, Gabriele
Re, Dino
Dellavia, Claudia
Giannì, Aldo Bruno - Abstract:
- <abstract xml:lang="en" abstract-type="author" id="ab005"> <title id="st005">Abstract</title> <sec> <p id="sp0005">This study evaluated the influence of two different occlusal indicators (articulating papers of 40 μm and 200 μm) on muscular activity of the temporalis anterior (TA) and superficial masseter (MS) during maximum voluntary clenches (MVC), using surface electromyography (SEMG). It was hypothesized that an articulating paper positioned between dental arches during MVC elicits a different muscular activity compared with the occlusion on natural dentition (without the occlusal indicator).</p> <p id="sp0010">30 healthy adult subjects with a complete, natural dentition were recruited; SEMG activity was recorded in the following experimental conditions: MVC with cotton rolls for standardization purposes; MVC on natural dentition; MVC onto the 40 μm or 200 μm paper indicator positioned on right or left side of the dental arch. Percentage Overlapping Coefficient (POC; separate values obtained for TA and MS), antero-posterior coefficient (APC) and total muscle activities (IMP) were the analyzed SEMG parameters.</p> <p id="sp0015">The use of an occlusal indicator statistically changed POC_TA, POC_MS and IMP median values (<italic>p</italic> &lt; 0.05). Both 40 μm and 200 μm occlusal papers did not significantly affect APC values (<italic>P</italic> = 0.86). A pronounced asymmetric muscular activity has been recorded with the introduction of an interocclusal media. All<abstract xml:lang="en" abstract-type="author" id="ab005"> <title id="st005">Abstract</title> <sec> <p id="sp0005">This study evaluated the influence of two different occlusal indicators (articulating papers of 40 μm and 200 μm) on muscular activity of the temporalis anterior (TA) and superficial masseter (MS) during maximum voluntary clenches (MVC), using surface electromyography (SEMG). It was hypothesized that an articulating paper positioned between dental arches during MVC elicits a different muscular activity compared with the occlusion on natural dentition (without the occlusal indicator).</p> <p id="sp0010">30 healthy adult subjects with a complete, natural dentition were recruited; SEMG activity was recorded in the following experimental conditions: MVC with cotton rolls for standardization purposes; MVC on natural dentition; MVC onto the 40 μm or 200 μm paper indicator positioned on right or left side of the dental arch. Percentage Overlapping Coefficient (POC; separate values obtained for TA and MS), antero-posterior coefficient (APC) and total muscle activities (IMP) were the analyzed SEMG parameters.</p> <p id="sp0015">The use of an occlusal indicator statistically changed POC_TA, POC_MS and IMP median values (<italic>p</italic> &lt; 0.05). Both 40 μm and 200 μm occlusal papers did not significantly affect APC values (<italic>P</italic> = 0.86). A pronounced asymmetric muscular activity has been recorded with the introduction of an interocclusal media. All indices of muscular activity did not differ between sexes (Kruskal Wallis test, <italic>P</italic> &gt; 0.05).</p> <p id="sp0020">In conclusion, the examined articulating papers affected two specific SEMG parameters (POC and IMP); the recorded muscular activity with the occlusal indicator varied regardless left or right side positioning, and independently from tested paper thicknesses.</p> </sec> </abstract> … (more)
- Is Part Of:
- Journal of electromyography and kinesiology. Volume 25:Issue 4(2015:Aug.)
- Journal:
- Journal of electromyography and kinesiology
- Issue:
- Volume 25:Issue 4(2015:Aug.)
- Issue Display:
- Volume 25, Issue 4 (2015)
- Year:
- 2015
- Volume:
- 25
- Issue:
- 4
- Issue Sort Value:
- 2015-0025-0004-0000
- Page Start:
- 612
- Page End:
- 618
- Publication Date:
- 2015-08
- Subjects:
- Electromyography -- Periodicals
Kinesiology -- Periodicals
Electromyography -- Periodicals
Movement -- physiology -- Periodicals
Muscles -- physiology -- Periodicals
Électromyographie -- Périodiques
Cinésiologie -- Périodiques
Electromyography
Kinesiology
Electronic journals
Periodicals
616.740757 - Journal URLs:
- http://www.sciencedirect.com/science/journal/10506411 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/10506411 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jelekin.2015.04.006 ↗
- Languages:
- English
- ISSNs:
- 1050-6411
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4974.855000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 3584.xml