Correcting for large vessel contamination in dynamic susceptibility contrast perfusion MRI by extension to a physiological model of the vasculature. Issue 1 (8th August 2014)
- Record Type:
- Journal Article
- Title:
- Correcting for large vessel contamination in dynamic susceptibility contrast perfusion MRI by extension to a physiological model of the vasculature. Issue 1 (8th August 2014)
- Main Title:
- Correcting for large vessel contamination in dynamic susceptibility contrast perfusion MRI by extension to a physiological model of the vasculature
- Authors:
- Chappell, Michael A.
Mehndiratta, Amit
Calamante, Fernando - Abstract:
- <abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="mrm25390-sec-0001" sec-type="section"> <title>Purpose</title> <p>Dynamic susceptibility contrast (DSC) perfusion images are contaminated by contributions from macro vascular signal arising from contrast agent within the larger arteries that do not contribute directly to the local tissue perfusion.</p> </sec> <sec id="mrm25390-sec-0002" sec-type="section"> <title>Methods</title> <p>A vascular model of the DSC perfusion signal was extended by the inclusion of a macro vascular component based on the arterial input function. This was implemented within a Bayesian nonlinear model‐fitting algorithm that included automatic model complexity reduction. Results were compared with existing methods that do not correct for the macro vascular contamination as well as an independent component analysis technique.</p> </sec> <sec id="mrm25390-sec-0003" sec-type="section"> <title>Results</title> <p>Macro vascular signal was identified in regions corresponding to larger arteries resulting in reductions by 62% within a region of interest identified with high contamination. Whereas visually similar results could be achieved with independent component analysis, it resulted in reductions in global tissue perfusion and was not robustly applicable to patient data.</p> </sec> <sec id="mrm25390-sec-0004" sec-type="section"> <title>Conclusion</title> <p>A model‐based strategy for correction of macro vascular<abstract abstract-type="main"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="mrm25390-sec-0001" sec-type="section"> <title>Purpose</title> <p>Dynamic susceptibility contrast (DSC) perfusion images are contaminated by contributions from macro vascular signal arising from contrast agent within the larger arteries that do not contribute directly to the local tissue perfusion.</p> </sec> <sec id="mrm25390-sec-0002" sec-type="section"> <title>Methods</title> <p>A vascular model of the DSC perfusion signal was extended by the inclusion of a macro vascular component based on the arterial input function. This was implemented within a Bayesian nonlinear model‐fitting algorithm that included automatic model complexity reduction. Results were compared with existing methods that do not correct for the macro vascular contamination as well as an independent component analysis technique.</p> </sec> <sec id="mrm25390-sec-0003" sec-type="section"> <title>Results</title> <p>Macro vascular signal was identified in regions corresponding to larger arteries resulting in reductions by 62% within a region of interest identified with high contamination. Whereas visually similar results could be achieved with independent component analysis, it resulted in reductions in global tissue perfusion and was not robustly applicable to patient data.</p> </sec> <sec id="mrm25390-sec-0004" sec-type="section"> <title>Conclusion</title> <p>A model‐based strategy for correction of macro vascular contamination in DSC perfusion images is feasible, although the model may currently need extending to more accurately account for nonlinear effects of contrast agent in large arteries. Magn Reson Med 74:280–290, 2015. © 2014 Wiley Periodicals, Inc.</p> </sec> </abstract> … (more)
- Is Part Of:
- Magnetic resonance in medicine. Volume 74:Issue 1(2015:Jul.)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 74:Issue 1(2015:Jul.)
- Issue Display:
- Volume 74, Issue 1 (2015)
- Year:
- 2015
- Volume:
- 74
- Issue:
- 1
- Issue Sort Value:
- 2015-0074-0001-0000
- Page Start:
- 280
- Page End:
- 290
- Publication Date:
- 2014-08-08
- Subjects:
- Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.25390 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 4256.xml