How to enhance the stability of locking plate fixation of proximal humerus fractures? An overview of current biomechanical and clinical data. Issue 7 (July 2015)
- Record Type:
- Journal Article
- Title:
- How to enhance the stability of locking plate fixation of proximal humerus fractures? An overview of current biomechanical and clinical data. Issue 7 (July 2015)
- Main Title:
- How to enhance the stability of locking plate fixation of proximal humerus fractures? An overview of current biomechanical and clinical data
- Authors:
- Schliemann, Benedikt
Wähnert, Dirk
Theisen, Christina
Herbort, Mirco
Kösters, Clemens
Raschke, Michael J.
Weimann, Andre - Abstract:
- <abstract abstract-type="author" id="abs0005"> <title id="sect0005">Abstract</title> <sec> <title id="sect0010">Background</title> <p id="spar0005">The complication rate after locking plate fixation of proximal humerus fractures is high. In addition to low bone mineral density, a lack of medial support has been identified as one of the most important factors accounting for mechanical instability. As a result of the high failure rate, different strategies have been developed to enhance the mechanical stability of locking plate fixation of proximal humerus fractures. The aim of the present article is to give an overview of the current biomechanical and clinical studies that focus on how to increase the stability of locking plate fixation of proximal humerus fractures.</p> </sec> <sec> <title id="sect0015">Methods</title> <p id="spar0010">A comprehensive search of the Medline databases using specific search terms with regard to the stability of locking plate fixation of proximal humerus fractures was performed. After screening of the articles for eligibility, they were subdivided according to clinical and biomechanical aspects.</p> </sec> <sec> <title id="sect0020">Results</title> <p id="spar0015">Medial support screws, filling of bone voids and screw-tip augmentation with bone cement as well as the application of bone grafts are currently the most frequently assessed and performed methods. Although the evidence is weak, all of the mentioned strategies appear to have a positive<abstract abstract-type="author" id="abs0005"> <title id="sect0005">Abstract</title> <sec> <title id="sect0010">Background</title> <p id="spar0005">The complication rate after locking plate fixation of proximal humerus fractures is high. In addition to low bone mineral density, a lack of medial support has been identified as one of the most important factors accounting for mechanical instability. As a result of the high failure rate, different strategies have been developed to enhance the mechanical stability of locking plate fixation of proximal humerus fractures. The aim of the present article is to give an overview of the current biomechanical and clinical studies that focus on how to increase the stability of locking plate fixation of proximal humerus fractures.</p> </sec> <sec> <title id="sect0015">Methods</title> <p id="spar0010">A comprehensive search of the Medline databases using specific search terms with regard to the stability of locking plate fixation of proximal humerus fractures was performed. After screening of the articles for eligibility, they were subdivided according to clinical and biomechanical aspects.</p> </sec> <sec> <title id="sect0020">Results</title> <p id="spar0015">Medial support screws, filling of bone voids and screw-tip augmentation with bone cement as well as the application of bone grafts are currently the most frequently assessed and performed methods. Although the evidence is weak, all of the mentioned strategies appear to have a positive effect on achieving and maintaining a stable reduction even of complex fractures.</p> </sec> <sec> <title id="sect0025">Conclusion</title> <p id="spar0020">Further clinical studies with a higher number of patients and a higher level of evidence are required to develop a standardised treatment algorithm with regard to cement augmentation and bone grafting. Although these measures are likely to have a stabilising effect on locking plate fixation, its general use cannot be fully recommended yet.</p> </sec> </abstract> … (more)
- Is Part Of:
- Injury. Volume 46:Issue 7(2015)
- Journal:
- Injury
- Issue:
- Volume 46:Issue 7(2015)
- Issue Display:
- Volume 46, Issue 7 (2015)
- Year:
- 2015
- Volume:
- 46
- Issue:
- 7
- Issue Sort Value:
- 2015-0046-0007-0000
- Page Start:
- 1207
- Page End:
- 1214
- Publication Date:
- 2015-07
- Subjects:
- Wounds and injuries -- Surgery -- Periodicals
Accidents -- Periodicals
Wounds and Injuries -- surgery -- Periodicals
Lésions et blessures -- Chirurgie -- Périodiques
Electronic journals
Electronic journals
617.1 - Journal URLs:
- http://www.sciencedirect.com/science/journal/00201383 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/00201383 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/00201383 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.injury.2015.04.020 ↗
- Languages:
- English
- ISSNs:
- 0020-1383
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4514.400000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 4115.xml