Evaluation of coronary adventitial vasa vasorum using 3D optical coherence tomography – Animal and human studies. Issue 1 (March 2015)
- Record Type:
- Journal Article
- Title:
- Evaluation of coronary adventitial vasa vasorum using 3D optical coherence tomography – Animal and human studies. Issue 1 (March 2015)
- Main Title:
- Evaluation of coronary adventitial vasa vasorum using 3D optical coherence tomography – Animal and human studies
- Authors:
- Aoki, Tatsuo
Rodriguez-Porcel, Martin
Matsuo, Yoshiki
Cassar, Andrew
Kwon, Teak-Geun
Franchi, Federico
Gulati, Rajiv
Kushwaha, Sudhir S.
Lennon, Ryan J.
Lerman, Lilach O.
Ritman, Erik L.
Lerman, Amir - Abstract:
- <abstract xml:lang="en" abstract-type="author" id="abs0010"> <title id="sectitle0010">Abstract</title> <sec> <title id="sectitle0015">Objectives</title> <p id="abspara0010">This study sought to evaluate adventitial vasa vasorum (VV) in vivo with novel imaging technique of optical coherence tomography (OCT).</p> </sec> <sec> <title id="sectitle0020">Methods</title> <p id="abspara0015">To verify OCT methods for quantification of VV, we first studied 2 swine carotid arteries in a model of focal angiogenesis by autologous blood injection, and compared microchannel volume (MCV) by OCT and VV by m-CT, and counts of those. In OCT images, adventitial MC was identified as signal-voiding areas which were located within 1 mm from the lumen-intima border. After manually tracing microchannel areas and the boundaries of lumen-intima and media-adventitial in all slices, we reconstructed 3D images. Moreover, we performed with OCT imaging in 8 recipients referred for evaluation of cardiac allograft vasculopathy at 1 year after heart transplantation. MCV and plaque volume (PV) were assessed with 3D images in each 10-mm-segment.</p> </sec> <sec> <title id="sectitle0025">Results</title> <p id="abspara0020">In the animal study, among the 16 corresponding 1-mm-segments, there were significant correlations of count and volume between both the modalities (count r<sup>2</sup> = 0.80, P &lt; 0.01; volume r<sup>2</sup> = 0.50, P &lt; 0.01) and a good agreement with a systemic bias toward<abstract xml:lang="en" abstract-type="author" id="abs0010"> <title id="sectitle0010">Abstract</title> <sec> <title id="sectitle0015">Objectives</title> <p id="abspara0010">This study sought to evaluate adventitial vasa vasorum (VV) in vivo with novel imaging technique of optical coherence tomography (OCT).</p> </sec> <sec> <title id="sectitle0020">Methods</title> <p id="abspara0015">To verify OCT methods for quantification of VV, we first studied 2 swine carotid arteries in a model of focal angiogenesis by autologous blood injection, and compared microchannel volume (MCV) by OCT and VV by m-CT, and counts of those. In OCT images, adventitial MC was identified as signal-voiding areas which were located within 1 mm from the lumen-intima border. After manually tracing microchannel areas and the boundaries of lumen-intima and media-adventitial in all slices, we reconstructed 3D images. Moreover, we performed with OCT imaging in 8 recipients referred for evaluation of cardiac allograft vasculopathy at 1 year after heart transplantation. MCV and plaque volume (PV) were assessed with 3D images in each 10-mm-segment.</p> </sec> <sec> <title id="sectitle0025">Results</title> <p id="abspara0020">In the animal study, among the 16 corresponding 1-mm-segments, there were significant correlations of count and volume between both the modalities (count r<sup>2</sup> = 0.80, P &lt; 0.01; volume r<sup>2</sup> = 0.50, P &lt; 0.01) and a good agreement with a systemic bias toward underestimation with m-CT. In the human study, there was a significant positive correlation between MCV and PV (segment number = 24, r<sup>2</sup> = 0.63, P &lt; 0.01).</p> </sec> <sec> <title id="sectitle0030">Conclusion</title> <p id="abspara0025">Our results suggest that evaluation of MCV with 3D OCT imaging might be a novel method to estimate the amount of adventitial VV in vivo, and further has the potential to provide a pathophysiological insight into a role of the VV in allograft vasculopathy.</p> </sec> </abstract> … (more)
- Is Part Of:
- Atherosclerosis. Volume 239:Issue 1(2015)
- Journal:
- Atherosclerosis
- Issue:
- Volume 239:Issue 1(2015)
- Issue Display:
- Volume 239, Issue 1 (2015)
- Year:
- 2015
- Volume:
- 239
- Issue:
- 1
- Issue Sort Value:
- 2015-0239-0001-0000
- Page Start:
- 203
- Page End:
- 208
- Publication Date:
- 2015-03
- Subjects:
- Arteriosclerosis -- Periodicals
Electronic journals
616.136 - Journal URLs:
- http://www.sciencedirect.com/science/journal/00219150 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/00219150 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.atherosclerosis.2015.01.016 ↗
- Languages:
- English
- ISSNs:
- 0021-9150
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 1765.874000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 3716.xml