Improving the sensitivity of the heat‐transfer method (HTM) for cancer cell detection with optimized sensor chips. Issue 6 (2nd February 2015)
- Record Type:
- Journal Article
- Title:
- Improving the sensitivity of the heat‐transfer method (HTM) for cancer cell detection with optimized sensor chips. Issue 6 (2nd February 2015)
- Main Title:
- Improving the sensitivity of the heat‐transfer method (HTM) for cancer cell detection with optimized sensor chips
- Authors:
- Eersels, K.
van Grinsven, B.
Vandenryt, T.
Jiménez‐Monroy, K. L.
Peeters, M.
Somers, V.
Püttmann, C.
Stein, C.
Barth, S.
Bos, G. M. J.
Germeraad, W. T. V.
Diliën, H.
Cleij, T. J.
Thoelen, R.
Ceuninck, W. De
Wagner, P. - Abstract:
- <abstract abstract-type="main" xml:lang="en"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="pssa201431709-sec-0001" sec-type="section"> <p>In this article, we increased the sensitivity of the heat‐transfer method (HTM) for the detection of breast cancer cells (ZR‐75‐1 cells, see figure) in phosphate buffered saline (PBS). The effect of small technological changes on the limit of detection (LoD) of the methodology was examined. To this extent, polished aluminum substrates with a mirror finish were used, replacing the unpolished chips used in previous studies. These chips were coated with a polyurethane layer and imprinted for the target cell type, creating a so‐called surface imprinted‐polymer (SIP). Binding of target cells to the SIP resulted in an increase of the thermal resistance at the solid‐liquid interface under study. Background thermal resistance measurements were performed with polished and unpolished aluminum substrates. In addition, the effect of using silver paste as thermal coupling between the aluminum chip and the copper heat provider was analyzed. The results of these experiments reveal that optimal thermal contact is achieved when directly coupling the copper heat provider to the polished side of the aluminum substrate as evidenced by a decrease in the baseline thermal resistance. In addition, noise levels on the heat‐transfer resistance (<italic>R</italic><sub>th</sub>) signal decreased by a factor in the optimal configuration.<abstract abstract-type="main" xml:lang="en"> <title> <x xml:space="preserve">Abstract</x> </title> <sec id="pssa201431709-sec-0001" sec-type="section"> <p>In this article, we increased the sensitivity of the heat‐transfer method (HTM) for the detection of breast cancer cells (ZR‐75‐1 cells, see figure) in phosphate buffered saline (PBS). The effect of small technological changes on the limit of detection (LoD) of the methodology was examined. To this extent, polished aluminum substrates with a mirror finish were used, replacing the unpolished chips used in previous studies. These chips were coated with a polyurethane layer and imprinted for the target cell type, creating a so‐called surface imprinted‐polymer (SIP). Binding of target cells to the SIP resulted in an increase of the thermal resistance at the solid‐liquid interface under study. Background thermal resistance measurements were performed with polished and unpolished aluminum substrates. In addition, the effect of using silver paste as thermal coupling between the aluminum chip and the copper heat provider was analyzed. The results of these experiments reveal that optimal thermal contact is achieved when directly coupling the copper heat provider to the polished side of the aluminum substrate as evidenced by a decrease in the baseline thermal resistance. In addition, noise levels on the heat‐transfer resistance (<italic>R</italic><sub>th</sub>) signal decreased by a factor in the optimal configuration. Dose‐response curves were obtained using the optimized methodology and were compared with results obtained with the original substrates. These quantitative experiments demonstrated an improvement of the LoD by approximately thirty percent.</p> <p>ZR‐75‐1 cells applied onto a home‐made rubber stamp.<inline-graphic xlink:href="ark:/27927/pgjwxk17r2" content-type="pssa201431709-gra-0001" xlink:type="simple" xmlns:xlink="http://www.w3.org/1999/xlink" /></p> </sec> </abstract> … (more)
- Is Part Of:
- Physica status solidi. Volume 212:Issue 6(2015:Jun.)
- Journal:
- Physica status solidi
- Issue:
- Volume 212:Issue 6(2015:Jun.)
- Issue Display:
- Volume 212, Issue 6 (2015)
- Year:
- 2015
- Volume:
- 212
- Issue:
- 6
- Issue Sort Value:
- 2015-0212-0006-0000
- Page Start:
- 1320
- Page End:
- 1326
- Publication Date:
- 2015-02-02
- Subjects:
- Solid state physics -- Periodicals
Solids -- Industrial applications -- Periodicals
530.41 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1002/pssa.201431709 ↗
- Languages:
- English
- ISSNs:
- 1862-6300
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.210000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 4243.xml