Assessment of cumulative external beam and intracavitary brachytherapy organ doses in gynecologic cancers using deformable dose summation. Issue 2 (May 2015)
- Record Type:
- Journal Article
- Title:
- Assessment of cumulative external beam and intracavitary brachytherapy organ doses in gynecologic cancers using deformable dose summation. Issue 2 (May 2015)
- Main Title:
- Assessment of cumulative external beam and intracavitary brachytherapy organ doses in gynecologic cancers using deformable dose summation
- Authors:
- Teo, Boon-Keng
Bonner Millar, Lara P.
Ding, Xuanfeng
Lin, Lilie L. - Abstract:
- <abstract xml:lang="en" abstract-type="author" id="ab005"> <title id="st095">Abstract</title> <sec> <title id="st055">Purpose</title> <p id="sp0005">Due to inter-fraction variation in applicator position, organ displacement and deformation, doses to targets and normal tissues may not be accurately represented by adding the doses from external beam radiation therapy (EBRT) and intracavitary brachytherapy (ICBT) using rigid image registration. Deformable image registration permits organ and applicators to be spatially matched in 3D, enabling more accurate tracking of the accumulated volumetric dose to the target as well as organs at risk (OAR). This study assesses the dosimetric impact of using deformable image registration to determine the cumulative EBRT and ICBT doses to the rectum and bladder.</p> </sec> <sec> <title id="st060">Methods and materials</title> <p id="sp0010">Data from 20 patients with stage IB1-IVA cervical cancer were analyzed. Nine of the patients were treated with ICBT and EBRT which included a nodal or parametrium boost while eleven were treated with ICBT and EBRT with no boost. Dose summation was performed in two stages. For the first stage, only the ICBT fractional doses were added using both "parameter adding" and deformable registration techniques. In the second stage, the ICBT and EBRT doses were combined using "parameter adding" in two ways. Partial "parameter adding" considers the cumulative ICBT dose from deformable registration as one parameter<abstract xml:lang="en" abstract-type="author" id="ab005"> <title id="st095">Abstract</title> <sec> <title id="st055">Purpose</title> <p id="sp0005">Due to inter-fraction variation in applicator position, organ displacement and deformation, doses to targets and normal tissues may not be accurately represented by adding the doses from external beam radiation therapy (EBRT) and intracavitary brachytherapy (ICBT) using rigid image registration. Deformable image registration permits organ and applicators to be spatially matched in 3D, enabling more accurate tracking of the accumulated volumetric dose to the target as well as organs at risk (OAR). This study assesses the dosimetric impact of using deformable image registration to determine the cumulative EBRT and ICBT doses to the rectum and bladder.</p> </sec> <sec> <title id="st060">Methods and materials</title> <p id="sp0010">Data from 20 patients with stage IB1-IVA cervical cancer were analyzed. Nine of the patients were treated with ICBT and EBRT which included a nodal or parametrium boost while eleven were treated with ICBT and EBRT with no boost. Dose summation was performed in two stages. For the first stage, only the ICBT fractional doses were added using both "parameter adding" and deformable registration techniques. In the second stage, the ICBT and EBRT doses were combined using "parameter adding" in two ways. Partial "parameter adding" considers the cumulative ICBT dose from deformable registration as one parameter while full "parameter adding" uses fractional ICBT parameters. The cumulative minimum doses to 2cc (D2cc) of the rectum and bladder were compared between deformable registration and "parameter adding" techniques.</p> </sec> <sec> <title id="st065">Results</title> <p id="sp0015">Dose summation of ICBT fractions only using deformable registration yielded D2cc values that were (10.1 ± 9.5)% lower for the rectum and (7.2 ± 6.3)% lower for the bladder compared to "parameter adding". When ICBT and EBRT doses were summed deformably, the group without EBRT boost had D2cc that were (0.0 ± 4.6)% and (−1.2 ± 2.9)% lower for the rectum and bladder respectively compared to partial "parameter adding". With EBRT boost, the differences were (−2.9 ± 4.0)% and (−3.2 ± 3.3)% for the rectum and bladder respectively. For full "parameter adding", the differences from deformable sum were (2.7 ± 5.0)%, (2.6 ± 5.0)% without EBRT boost and (0.6 ± 4.8)%, (−1.5 ± 3.7)% with EBRT boost.</p> </sec> <sec> <title id="st070">Conclusion</title> <p id="sp0020">Comparison of deformable dose summation with the technique of "parameter adding" suggests that "parameter adding" can be used as a good approximation of D2cc when adding ICBT and EBRT doses with or without boost. With EBRT boosts, deformable dose summation may more accurately represent dose to normal critical structures but these differences remain small compared to "parameter adding".</p> </sec> </abstract> … (more)
- Is Part Of:
- Radiotherapy and oncology. Volume 115:Issue 2(2015:May)
- Journal:
- Radiotherapy and oncology
- Issue:
- Volume 115:Issue 2(2015:May)
- Issue Display:
- Volume 115, Issue 2 (2015)
- Year:
- 2015
- Volume:
- 115
- Issue:
- 2
- Issue Sort Value:
- 2015-0115-0002-0000
- Page Start:
- 195
- Page End:
- 202
- Publication Date:
- 2015-05
- Subjects:
- Oncology -- Periodicals
Radiotherapy -- Periodicals
Tumors -- Periodicals
Medical Oncology -- Periodicals
Neoplasms -- radiotherapy -- Periodicals
Radiotherapy -- Periodicals
Radiothérapie -- Périodiques
Cancérologie -- Périodiques
Tumeurs -- Périodiques
Electronic journals
616.9940642 - Journal URLs:
- http://www.sciencedirect.com/science/journal/01678140 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/01678140 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/01678140 ↗
http://www.estro.org/ ↗
http://www.elsevier.com/journals ↗
http://www.journals.elsevier.com/radiotherapy-and-oncology/ ↗ - DOI:
- 10.1016/j.radonc.2015.04.002 ↗
- Languages:
- English
- ISSNs:
- 0167-8140
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7240.790000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 3856.xml