Η1‐Allypalladium Complexes with Tridentate PNP' Ligand for the Assembly of Modified Screen Printed Electrodes: an Electrochemical Study. Issue 6 (5th March 2015)
- Record Type:
- Journal Article
- Title:
- Η1‐Allypalladium Complexes with Tridentate PNP' Ligand for the Assembly of Modified Screen Printed Electrodes: an Electrochemical Study. Issue 6 (5th March 2015)
- Main Title:
- Η1‐Allypalladium Complexes with Tridentate PNP' Ligand for the Assembly of Modified Screen Printed Electrodes: an Electrochemical Study
- Authors:
- Valentini, F.
Ciambella, E.
Antonaroli, S.
Boaretto, A.
Mannino, P.
La Parola, V. - Abstract:
- <abstract abstract-type="main" xml:lang="en"> <title>Abstract</title> <p>Specific Pd‐based organometallic complex, in particular the [Pd(η<sup>1</sup>‐CH<sub>2</sub>CH=CH<sub>2</sub>)(PNP')]BF<sub>4</sub> was used for the assembly of chemically modified Screen Printed Electrodes (SPEs) and their electrochemical reactivity was also investigated. For this purpose potassium ferricyanide, hexaammineruthenium(III) chloride, sodium hexachloroiridate‐(III) hydrate, ascorbic acid (AA), uric acid (UA), acetaminophen (Ac), guanine (G) and adenine (A) were used to study the electron‐transfer processes, which occurred at modified SPEs, fabricated by using the [Pd(η<sup>1</sup>‐CH<sub>2</sub>CH=CH<sub>2</sub>)(PNP')]BF<sub>4</sub>, applying the drop casting procedure. Interesting results were obtained in the case of the guanine (G) quantitative detection, especially in terms of a wide range of concentration (2.5–40 nM), an high sensitivity (of 49.0 A M<sup>−1</sup> cm<sup>−2</sup>), a low detection limit (<italic>LOD</italic>=1.0 nM) and a fast response time (of <italic>t</italic>=2 s). The intra‐electrode reproducibility (<italic>RSD</italic>%) was &lt;1 % for the same SPE used for each point of the calibration plot. The inter‐electrode reproducibility (<italic>RSD</italic>%), estimated by using different SPEs for each single point of the quantitative calibration graph, ranging from 5 to 10 %, better than that exhibited by other different chemical sensors, described in literature,<abstract abstract-type="main" xml:lang="en"> <title>Abstract</title> <p>Specific Pd‐based organometallic complex, in particular the [Pd(η<sup>1</sup>‐CH<sub>2</sub>CH=CH<sub>2</sub>)(PNP')]BF<sub>4</sub> was used for the assembly of chemically modified Screen Printed Electrodes (SPEs) and their electrochemical reactivity was also investigated. For this purpose potassium ferricyanide, hexaammineruthenium(III) chloride, sodium hexachloroiridate‐(III) hydrate, ascorbic acid (AA), uric acid (UA), acetaminophen (Ac), guanine (G) and adenine (A) were used to study the electron‐transfer processes, which occurred at modified SPEs, fabricated by using the [Pd(η<sup>1</sup>‐CH<sub>2</sub>CH=CH<sub>2</sub>)(PNP')]BF<sub>4</sub>, applying the drop casting procedure. Interesting results were obtained in the case of the guanine (G) quantitative detection, especially in terms of a wide range of concentration (2.5–40 nM), an high sensitivity (of 49.0 A M<sup>−1</sup> cm<sup>−2</sup>), a low detection limit (<italic>LOD</italic>=1.0 nM) and a fast response time (of <italic>t</italic>=2 s). The intra‐electrode reproducibility (<italic>RSD</italic>%) was &lt;1 % for the same SPE used for each point of the calibration plot. The inter‐electrode reproducibility (<italic>RSD</italic>%), estimated by using different SPEs for each single point of the quantitative calibration graph, ranging from 5 to 10 %, better than that exhibited by other different chemical sensors, described in literature, and reported in this work for comparison. In addition, the high selectivity of the chemically modified sensors toward the oxidation of guanine, exhibited in presence of a mixture of G+A, in the same electrochemical bath solution, could be related to the different electro‐catalytic mechanisms, as demonstrated by the XPS study. This chemical sensor prototype could be very promising for bio‐medicine applications.</p> </abstract> … (more)
- Is Part Of:
- Electroanalysis. Volume 27:Issue 6(2015:Jun.)
- Journal:
- Electroanalysis
- Issue:
- Volume 27:Issue 6(2015:Jun.)
- Issue Display:
- Volume 27, Issue 6 (2015)
- Year:
- 2015
- Volume:
- 27
- Issue:
- 6
- Issue Sort Value:
- 2015-0027-0006-0000
- Page Start:
- 1479
- Page End:
- 1489
- Publication Date:
- 2015-03-05
- Subjects:
- Electrochemical analysis -- Periodicals
Chemistry, Analytical -- Periodicals
Electrochemistry -- Periodicals
543.4 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1521-4109 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/elan.201400558 ↗
- Languages:
- English
- ISSNs:
- 1040-0397
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3698.789000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 4092.xml