Continuous monitoring of haemoglobin concentration after in‐vivo adjustment in patients undergoing surgery with blood loss1. (13th February 2015)
- Record Type:
- Journal Article
- Title:
- Continuous monitoring of haemoglobin concentration after in‐vivo adjustment in patients undergoing surgery with blood loss1. (13th February 2015)
- Main Title:
- Continuous monitoring of haemoglobin concentration after in‐vivo adjustment in patients undergoing surgery with blood loss1
- Authors:
- Frasca, D.
Mounios, H.
Giraud, B.
Boisson, M.
Debaene, B.
Mimoz, O. - Abstract:
- <abstract abstract-type="main" id="anae13028-abs-0001"> <title>Summary</title> <p>Non‐invasive monitoring of haemoglobin concentration provides real‐time measurement of haemoglobin concentration (SpHb) using multi‐wavelength pulse co‐oximetry. We hypothesised that in‐vivo adjustment using the mean of three haemoglobinometer (HemoCue<sup>®</sup>) measurements from an arterial blood sample at the first SpHb measurement (HCueART) would increase the accuracy of the monitor. The study included 41 adults for a total of 173 measurements of haemoglobin concentration. In‐vivo adjusted SpHb was automatically calculated by the following formula: in‐vivo adjusted SpHb = unadjusted SpHb − (SpHb − HCueART). The accuracy of in‐vivo adjusted SpHb was compared with SpHb retrospectively adjusted using the same formula, except for haemoglobin level which was assessed at the central laboratory and then compared with all other available invasive methods of haemoglobin measurement (co‐oximetry, HbSAT; arterial HemoCue, HCueART; capillary HemoCue, HCueCAP). Compared with laboratory measurement of haemoglobin concentration, bias (precision) for unadjusted SpHb, in‐vivo adjusted SpHb, retrospectively adjusted SpHb, HbSAT, HCueART and HCueCAP were −0.4 (1.4), −0.3 (1.1), −0.3 (1.1), −0.6 (0.7), 0.0 (0.4) and −0.5 (1.2) g.dl<sup>−1</sup>, respectively. In‐vivo adjustment of SpHb values using the mean of three arterial HemoCue measurements improved the accuracy of the device similar to those observed<abstract abstract-type="main" id="anae13028-abs-0001"> <title>Summary</title> <p>Non‐invasive monitoring of haemoglobin concentration provides real‐time measurement of haemoglobin concentration (SpHb) using multi‐wavelength pulse co‐oximetry. We hypothesised that in‐vivo adjustment using the mean of three haemoglobinometer (HemoCue<sup>®</sup>) measurements from an arterial blood sample at the first SpHb measurement (HCueART) would increase the accuracy of the monitor. The study included 41 adults for a total of 173 measurements of haemoglobin concentration. In‐vivo adjusted SpHb was automatically calculated by the following formula: in‐vivo adjusted SpHb = unadjusted SpHb − (SpHb − HCueART). The accuracy of in‐vivo adjusted SpHb was compared with SpHb retrospectively adjusted using the same formula, except for haemoglobin level which was assessed at the central laboratory and then compared with all other available invasive methods of haemoglobin measurement (co‐oximetry, HbSAT; arterial HemoCue, HCueART; capillary HemoCue, HCueCAP). Compared with laboratory measurement of haemoglobin concentration, bias (precision) for unadjusted SpHb, in‐vivo adjusted SpHb, retrospectively adjusted SpHb, HbSAT, HCueART and HCueCAP were −0.4 (1.4), −0.3 (1.1), −0.3 (1.1), −0.6 (0.7), 0.0 (0.4) and −0.5 (1.2) g.dl<sup>−1</sup>, respectively. In‐vivo adjustment of SpHb values using the mean of three arterial HemoCue measurements improved the accuracy of the device similar to those observed after a retrospective adjustment using central laboratory haemoglobin level.</p> </abstract> … (more)
- Is Part Of:
- Anaesthesia. Volume 70:Number 7(2015:Jul.)
- Journal:
- Anaesthesia
- Issue:
- Volume 70:Number 7(2015:Jul.)
- Issue Display:
- Volume 70, Issue 7 (2015)
- Year:
- 2015
- Volume:
- 70
- Issue:
- 7
- Issue Sort Value:
- 2015-0070-0007-0000
- Page Start:
- 803
- Page End:
- 809
- Publication Date:
- 2015-02-13
- Subjects:
- Anesthesia -- Periodicals
617.96 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1365-2044 ↗
http://onlinelibrary.wiley.com/ ↗
http://www.aagbi.org/publications ↗ - DOI:
- 10.1111/anae.13028 ↗
- Languages:
- English
- ISSNs:
- 0003-2409
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0859.900000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 3135.xml