Three-Tesla Imaging of the Pituitary and Parasellar Region. Issue 3 (May 2015)
- Record Type:
- Journal Article
- Title:
- Three-Tesla Imaging of the Pituitary and Parasellar Region. Issue 3 (May 2015)
- Main Title:
- Three-Tesla Imaging of the Pituitary and Parasellar Region
- Authors:
- Lien, Ruby J.
Corcuera-Solano, Idoia
Pawha, Puneet S.
Naidich, Thomas P.
Tanenbaum, Lawrence N. - Abstract:
- <abstract> <title> <x xml:space="preserve">Abstract</x> </title> <sec> <title>Objective</title> <p>We explored how a novel T1-weighted 3-dimensional (3D) fast spin echo (FSE) sequence (Cube; GE, Waukesha, Wis) might outperform conventional 2-dimensional (2D) FSE techniques for contrast-enhanced imaging of the pituitary and parasellar region.</p> </sec> <sec> <title>Methods</title> <p>Ninety-one patients were imaged with 3D Cube and conventional 2D FSE on a 3.0-T magnetic resonance scanner. Two neuroradiologists independently assessed images for anatomical delineation (infundibulum, optic apparatus, and cavernous sinus), degree of artifact, and confidence in lesion definition or exclusion using a 5-point scale. In addition, the readers were asked to rank overall preference.</p> </sec> <sec> <title>Results</title> <p>Readers A and B found 3D Cube to be better or equal to 2D FSE in 84% and 86% of the cases. Three-dimensional Cube provided significantly better images than 2D FSE with respect to delineation of the infundibulum (<italic>P</italic> &lt; 0.0001), cavernous sinus (<italic>P</italic> &lt; 0.0001), optic apparatus (<italic>P</italic> = 0.002 for reader A and <italic>P</italic> = 0.265 for reader B), and fewer artifacts at the sellar floor (<italic>P</italic> &lt; 0.0001). Three-dimensional Cube provided greater lesion conspicuity or confidence in lesion exclusion (<italic>P</italic> &lt; 0.0001).</p> </sec> <sec> <title>Conclusions</title> <p>Three-dimensional Cube<abstract> <title> <x xml:space="preserve">Abstract</x> </title> <sec> <title>Objective</title> <p>We explored how a novel T1-weighted 3-dimensional (3D) fast spin echo (FSE) sequence (Cube; GE, Waukesha, Wis) might outperform conventional 2-dimensional (2D) FSE techniques for contrast-enhanced imaging of the pituitary and parasellar region.</p> </sec> <sec> <title>Methods</title> <p>Ninety-one patients were imaged with 3D Cube and conventional 2D FSE on a 3.0-T magnetic resonance scanner. Two neuroradiologists independently assessed images for anatomical delineation (infundibulum, optic apparatus, and cavernous sinus), degree of artifact, and confidence in lesion definition or exclusion using a 5-point scale. In addition, the readers were asked to rank overall preference.</p> </sec> <sec> <title>Results</title> <p>Readers A and B found 3D Cube to be better or equal to 2D FSE in 84% and 86% of the cases. Three-dimensional Cube provided significantly better images than 2D FSE with respect to delineation of the infundibulum (<italic>P</italic> &lt; 0.0001), cavernous sinus (<italic>P</italic> &lt; 0.0001), optic apparatus (<italic>P</italic> = 0.002 for reader A and <italic>P</italic> = 0.265 for reader B), and fewer artifacts at the sellar floor (<italic>P</italic> &lt; 0.0001). Three-dimensional Cube provided greater lesion conspicuity or confidence in lesion exclusion (<italic>P</italic> &lt; 0.0001).</p> </sec> <sec> <title>Conclusions</title> <p>Three-dimensional Cube provides superior quality with thinner slices as well as diminished artifact and can replace conventional 2D FSE sequences for routine evaluations of the pituitary and parasellar region.</p> </sec> </abstract> … (more)
- Is Part Of:
- Journal of computer assisted tomography. Volume 39:Issue 3(2015)
- Journal:
- Journal of computer assisted tomography
- Issue:
- Volume 39:Issue 3(2015)
- Issue Display:
- Volume 39, Issue 3 (2015)
- Year:
- 2015
- Volume:
- 39
- Issue:
- 3
- Issue Sort Value:
- 2015-0039-0003-0000
- Page Start:
- Page End:
- Publication Date:
- 2015-05
- Subjects:
- Tomography -- Periodicals
Tomography -- Periodicals
Tomography
Periodicals
616.0757 - Journal URLs:
- http://journals.lww.com/jcat/pages/default.aspx ↗
http://ovidsp.tx.ovid.com ↗
http://www.jcat.org ↗
http://www.rad.bqsm.edu/jcat ↗
http://journals.lww.com ↗
http://www.lww.com/Product/0363-8715 ↗ - DOI:
- 10.1097/RCT.0000000000000214 ↗
- Languages:
- English
- ISSNs:
- 0363-8715
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4963.650000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 3331.xml