The Influence of the Tolerance between Mechanical Components on the Accuracy of Implants Inserted with a Stereolithographic Surgical Guide: A Retrospective Clinical Study. (24th July 2013)
- Record Type:
- Journal Article
- Title:
- The Influence of the Tolerance between Mechanical Components on the Accuracy of Implants Inserted with a Stereolithographic Surgical Guide: A Retrospective Clinical Study. (24th July 2013)
- Main Title:
- The Influence of the Tolerance between Mechanical Components on the Accuracy of Implants Inserted with a Stereolithographic Surgical Guide: A Retrospective Clinical Study
- Authors:
- Cassetta, Michele
Di Mambro, Alfonso
Di Giorgio, Gianni
Stefanelli, Luigi V.
Barbato, Ersilia - Abstract:
- <abstract abstract-type="main"> <title>Abstract</title> <sec id="cid12120-sec-0001" sec-type="section"> <title>Background</title> <p>The stereolithographic‐guided surgery system involves a sequence of diagnostic and therapeutic events, and errors can arise at different stages. In these systems, one of the potentially clinically relevant errors may be the mechanical errors caused by the bur‐guide gap due to the presence of a rotational allowance of the drills in the tubes.</p> </sec> <sec id="cid12120-sec-0002" sec-type="section"> <title>Purpose</title> <p>The purpose of this retrospective clinical study is to determine if it is possible to reduce the total error by limiting the tolerance among the mechanical components and to evaluate its clinical incidence.</p> </sec> <sec id="cid12120-sec-0003" sec-type="section"> <title>Materials and Methods</title> <p>Sixty‐six implants were inserted using the External Hex Safe® (Materialise Dental, Leuven, Belgium) system (Group A), and 71 implants were inserted using the same system with mechanical components modified to minimize the tolerance (Group B). Regarding only the angular deviation values, the <italic>t</italic>‐test was used to determine the influence of reduced tolerance among the mechanical components on the accuracy values.</p> </sec> <sec id="cid12120-sec-0004" sec-type="section"> <title>Results</title> <p> <italic>t</italic>‐Test showed that there is a statistically significant better accuracy with the modified system<abstract abstract-type="main"> <title>Abstract</title> <sec id="cid12120-sec-0001" sec-type="section"> <title>Background</title> <p>The stereolithographic‐guided surgery system involves a sequence of diagnostic and therapeutic events, and errors can arise at different stages. In these systems, one of the potentially clinically relevant errors may be the mechanical errors caused by the bur‐guide gap due to the presence of a rotational allowance of the drills in the tubes.</p> </sec> <sec id="cid12120-sec-0002" sec-type="section"> <title>Purpose</title> <p>The purpose of this retrospective clinical study is to determine if it is possible to reduce the total error by limiting the tolerance among the mechanical components and to evaluate its clinical incidence.</p> </sec> <sec id="cid12120-sec-0003" sec-type="section"> <title>Materials and Methods</title> <p>Sixty‐six implants were inserted using the External Hex Safe® (Materialise Dental, Leuven, Belgium) system (Group A), and 71 implants were inserted using the same system with mechanical components modified to minimize the tolerance (Group B). Regarding only the angular deviation values, the <italic>t</italic>‐test was used to determine the influence of reduced tolerance among the mechanical components on the accuracy values.</p> </sec> <sec id="cid12120-sec-0004" sec-type="section"> <title>Results</title> <p> <italic>t</italic>‐Test showed that there is a statistically significant better accuracy with the modified system (Group B).</p> </sec> <sec id="cid12120-sec-0005" sec-type="section"> <title>Conclusions</title> <p>Limiting the error that originates from mechanical components, total error could be statistically significantly reduced. Mechanical error is one of the most important source of error using External Hex Safe stereolithographic surgical guide.</p> </sec> </abstract> … (more)
- Is Part Of:
- Clinical implant dentistry and related research. Volume 17:Number 3(2015:Jun.)
- Journal:
- Clinical implant dentistry and related research
- Issue:
- Volume 17:Number 3(2015:Jun.)
- Issue Display:
- Volume 17, Issue 3 (2015)
- Year:
- 2015
- Volume:
- 17
- Issue:
- 3
- Issue Sort Value:
- 2015-0017-0003-0000
- Page Start:
- 580
- Page End:
- 588
- Publication Date:
- 2013-07-24
- Subjects:
- Dental implants -- Periodicals
Dental Implantation -- Periodicals
Dental Implants -- Periodicals
617.693 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1111/cid.12120 ↗
- Languages:
- English
- ISSNs:
- 1523-0899
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.293825
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 4075.xml