Enhanced Perfusion During Advanced Life Support Improves Survival With Favorable Neurologic Function in a Porcine Model of Refractory Cardiac Arrest. Issue 5 (May 2015)
- Record Type:
- Journal Article
- Title:
- Enhanced Perfusion During Advanced Life Support Improves Survival With Favorable Neurologic Function in a Porcine Model of Refractory Cardiac Arrest. Issue 5 (May 2015)
- Main Title:
- Enhanced Perfusion During Advanced Life Support Improves Survival With Favorable Neurologic Function in a Porcine Model of Refractory Cardiac Arrest
- Authors:
- Debaty, Guillaume
Metzger, Anja
Rees, Jennifer
McKnite, Scott
Puertas, Laura
Yannopoulos, Demetris
Lurie, Keith - Abstract:
- <abstract> <title> <x xml:space="preserve">Abstract</x> </title> <sec> <title>Objective:</title> <p>To improve the likelihood for survival with favorable neurologic function after cardiac arrest, we assessed a new advanced life support approach using active compression-decompression cardiopulmonary resuscitation plus an intrathoracic pressure regulator.</p> </sec> <sec> <title>Design:</title> <p>Prospective animal investigation.</p> </sec> <sec> <title>Setting:</title> <p>Animal laboratory.</p> </sec> <sec> <title>Subjects:</title> <p>Female farm pigs (<italic>n</italic> = 25) (39 ± 3 kg).</p> </sec> <sec> <title>Interventions:</title> <p>Protocol A: After 12 minutes of untreated ventricular fibrillation, 18 pigs were randomized to group A—3 minutes of basic life support with standard cardiopulmonary resuscitation, defibrillation, and if needed 2 minutes of advanced life support with standard cardiopulmonary resuscitation; group B—3 minutes of basic life support with standard cardiopulmonary resuscitation, defibrillation, and if needed 2 minutes of advanced life support with active compression-decompression plus intrathoracic pressure regulator; and group C—3 minutes of basic life support with active compression-decompression cardiopulmonary resuscitation plus an impedance threshold device, defibrillation, and if needed 2 minutes of advanced life support with active compression-decompression plus intrathoracic pressure regulator. Advanced life support always included IV<abstract> <title> <x xml:space="preserve">Abstract</x> </title> <sec> <title>Objective:</title> <p>To improve the likelihood for survival with favorable neurologic function after cardiac arrest, we assessed a new advanced life support approach using active compression-decompression cardiopulmonary resuscitation plus an intrathoracic pressure regulator.</p> </sec> <sec> <title>Design:</title> <p>Prospective animal investigation.</p> </sec> <sec> <title>Setting:</title> <p>Animal laboratory.</p> </sec> <sec> <title>Subjects:</title> <p>Female farm pigs (<italic>n</italic> = 25) (39 ± 3 kg).</p> </sec> <sec> <title>Interventions:</title> <p>Protocol A: After 12 minutes of untreated ventricular fibrillation, 18 pigs were randomized to group A—3 minutes of basic life support with standard cardiopulmonary resuscitation, defibrillation, and if needed 2 minutes of advanced life support with standard cardiopulmonary resuscitation; group B—3 minutes of basic life support with standard cardiopulmonary resuscitation, defibrillation, and if needed 2 minutes of advanced life support with active compression-decompression plus intrathoracic pressure regulator; and group C—3 minutes of basic life support with active compression-decompression cardiopulmonary resuscitation plus an impedance threshold device, defibrillation, and if needed 2 minutes of advanced life support with active compression-decompression plus intrathoracic pressure regulator. Advanced life support always included IV epinephrine (0.05 μg/kg). The primary endpoint was the 24-hour Cerebral Performance Category score. Protocol B: Myocardial and cerebral blood flow were measured in seven pigs before ventricular fibrillation and then following 6 minutes of untreated ventricular fibrillation during sequential 5 minutes treatments with active compression-decompression plus impedance threshold device, active compression-decompression plus intrathoracic pressure regulator, and active compression-decompression plus intrathoracic pressure regulator plus epinephrine.</p> </sec> <sec> <title>Measurements and Main Results:</title> <p>Protocol A: One of six pigs survived for 24 hours in group A versus six of six in groups B and C (<italic>p</italic> = 0.002) and Cerebral Performance Category scores were 4.7 ± 0.8, 1.7 ± 0.8, and 1.0 ± 0, respectively (<italic>p</italic> = 0.001). Protocol B: Brain blood flow was significantly higher with active compression-decompression plus intrathoracic pressure regulator compared with active compression-decompression plus impedance threshold device (0.39 ± 0.23 vs 0.27 ± 0.14 mL/min/g; <italic>p</italic> = 0.03), whereas differences in myocardial perfusion were not statistically significant (0.65 ± 0.81 vs 0.42 ± 0.36 mL/min/g; <italic>p</italic> = 0.23). Brain and myocardial blood flow with active compression-decompression plus intrathoracic pressure regulator plus epinephrine were significantly increased versus active compression-decompression plus impedance threshold device (0.40 ± 0.22 and 0.84 ± 0.60 mL/min/g; <italic>p</italic> = 0.02 for both).</p> </sec> <sec> <title>Conclusion:</title> <p>Advanced life support with active compression-decompression plus intrathoracic pressure regulator significantly improved cerebral perfusion and 24-hour survival with favorable neurologic function. These findings support further evaluation of this new advanced life support methodology in humans.</p> </sec> </abstract> … (more)
- Is Part Of:
- Critical care medicine. Volume 43:Issue 5(2015)
- Journal:
- Critical care medicine
- Issue:
- Volume 43:Issue 5(2015)
- Issue Display:
- Volume 43, Issue 5 (2015)
- Year:
- 2015
- Volume:
- 43
- Issue:
- 5
- Issue Sort Value:
- 2015-0043-0005-0000
- Page Start:
- Page End:
- Publication Date:
- 2015-05
- Subjects:
- Critical care medicine -- Periodicals
Soins intensifs -- Périodiques
616.028 - Journal URLs:
- http://journals.lww.com/ccmjournal/Pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/CCM.0000000000000939 ↗
- Languages:
- English
- ISSNs:
- 0090-3493
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3487.451000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 3966.xml