Validating prediction equations for mid-arm circumference measurements in adults. Issue 3 (June 2015)
- Record Type:
- Journal Article
- Title:
- Validating prediction equations for mid-arm circumference measurements in adults. Issue 3 (June 2015)
- Main Title:
- Validating prediction equations for mid-arm circumference measurements in adults
- Authors:
- Nwankwo, Tatiana
Ostchega, Yechiam
Zhang, Guangyu
Hughes, Jeffery P. - Abstract:
- <abstract> <title> <x xml:space="preserve">Abstract</x> </title> <sec> <title>Background</title> <p>Accurate measurement of blood pressure (BP) requires choosing an appropriate BP cuff size.</p> </sec> <sec> <title>Objectives</title> <p>The objective of this study was to examine the validity of regression equations to predict mid-arm circumference (mid-AC) using 2001–2012 National Health and Nutrition Examination Survey height and weight data.</p> </sec> <sec> <title>Methods</title> <p>National Health and Nutrition Examination Survey uses a complex multistage probability sample design to represent the civilian, noninstitutionalized US resident population. The sample consisted of 29 745 participants aged 20 years and older.</p> </sec> <sec> <title>Results</title> <p>For both men and women, the correlations between the predicted and measured mid-AC values were as follows: <italic>r</italic>=0.91 and 0.92, <italic>P</italic>&lt;0.001, respectively. For both sexes, the difference between the predicted and measured mid-AC mean values was less than 1.5 cm. The overall percent agreement for selecting the appropriate BP cuff, using the American Heart Association cuff size criteria and comparing the predicted mid-AC values with measured values, was 83.0% for men and 80.0% for women. The percent agreement for small adult cuff was 10.0% for men and 54.0% for women; for adult cuff it was 87.0% for men and 88.0% for women; for large adult cuff it was 82.0% for men and 80.0% for women;<abstract> <title> <x xml:space="preserve">Abstract</x> </title> <sec> <title>Background</title> <p>Accurate measurement of blood pressure (BP) requires choosing an appropriate BP cuff size.</p> </sec> <sec> <title>Objectives</title> <p>The objective of this study was to examine the validity of regression equations to predict mid-arm circumference (mid-AC) using 2001–2012 National Health and Nutrition Examination Survey height and weight data.</p> </sec> <sec> <title>Methods</title> <p>National Health and Nutrition Examination Survey uses a complex multistage probability sample design to represent the civilian, noninstitutionalized US resident population. The sample consisted of 29 745 participants aged 20 years and older.</p> </sec> <sec> <title>Results</title> <p>For both men and women, the correlations between the predicted and measured mid-AC values were as follows: <italic>r</italic>=0.91 and 0.92, <italic>P</italic>&lt;0.001, respectively. For both sexes, the difference between the predicted and measured mid-AC mean values was less than 1.5 cm. The overall percent agreement for selecting the appropriate BP cuff, using the American Heart Association cuff size criteria and comparing the predicted mid-AC values with measured values, was 83.0% for men and 80.0% for women. The percent agreement for small adult cuff was 10.0% for men and 54.0% for women; for adult cuff it was 87.0% for men and 88.0% for women; for large adult cuff it was 82.0% for men and 80.0% for women; and for thigh cuff it was 84.0% for men and 74.0% for women. All agreement statistics were above chance (for men, <italic>γ</italic>=0.96, and Kendall's Tau-b=0.73; for women, <italic>γ</italic>=0.97, and Kendall's Tau-b=0.76).</p> </sec> <sec> <title>Conclusion</title> <p>When possible, mid-AC should be directly measured for appropriate BP cuffing; however, the results of this validation study suggest that the prediction equations for mid-AC estimations were highly correlated and had an overall 80.0% agreement with measured mid-AC.</p> </sec> </abstract> … (more)
- Is Part Of:
- Blood pressure monitoring. Volume 20:Issue 3(2015)
- Journal:
- Blood pressure monitoring
- Issue:
- Volume 20:Issue 3(2015)
- Issue Display:
- Volume 20, Issue 3 (2015)
- Year:
- 2015
- Volume:
- 20
- Issue:
- 3
- Issue Sort Value:
- 2015-0020-0003-0000
- Page Start:
- Page End:
- Publication Date:
- 2015-06
- Subjects:
- Blood pressure -- Measurement -- Periodicals
Blood Pressure Determination -- Periodicals
Blood Pressure Monitoring, Ambulatory -- Periodicals
Blood Pressure Monitors -- Periodicals
Hypertension -- Periodicals
612.140287 - Journal URLs:
- http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&PAGE=toc&D=ovft&AN=00126097-000000000-00000&NEWS=N ↗
http://ovidsp.ovid.com/ovidweb.cgi?T=JS&NEWS=n&CSC=Y&PAGE=toc&D=yrovft&AN=00126097-000000000-00000 ↗
http://www.bpmonitoring.com/ ↗
http://journals.lww.com/pages/default.aspx ↗
http://firstsearch.oclc.org ↗ - DOI:
- 10.1097/MBP.0000000000000107 ↗
- Languages:
- English
- ISSNs:
- 1359-5237
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 2113.035500
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 4237.xml