Five millimetre-instruments in paediatric robotic surgery: Advantages and shortcomings. Issue 3 (June 2014)
- Record Type:
- Journal Article
- Title:
- Five millimetre-instruments in paediatric robotic surgery: Advantages and shortcomings. Issue 3 (June 2014)
- Main Title:
- Five millimetre-instruments in paediatric robotic surgery: Advantages and shortcomings
- Authors:
- Pelizzo, Gloria
Nakib, Ghassan
Romano, Piero
Avolio, Luigi
Mencherini, Simonetta
Zambaiti, Elisa
Raffaele, Alessandro
Stoll, Timothée
Mineo, Nicolò
Calcaterra, Valeria - Abstract:
- <abstract> <title>Abstract</title> <p> <bold> <italic>Purpose:</italic> </bold> The study was designed to assess the utility and controversies surrounding the usage of 5-mm instruments in paediatric robotic surgery. Adequate, delicate instruments for surgery in very narrow spaces are still lacking. <bold><italic>Material and methods</italic></bold>: Thirty children underwent elective abdominal robotic surgery. Working sites, assembly and operative time, hospital stay, advantages, complications and shortcomings are reported. <bold><italic>Results</italic></bold>: Interventions were performed in the following anatomical sites: 11 upper abdominal, nine pelvic, ten renal procedures. The majority of procedures required two operative trocars. A 2–3 mm accessory port was necessary for operations in the renal area and upper abdomen. The ports had to be placed at least 3 cm from the costal margins and superior iliac spines and at an angle of at least 130° with respect to the camera trocar. This configuration allowed intra-corporal knotting, vessel ligation and dissection with instruments in the inverted position. Operative times and hospital stays were similar to those reported for 8 mm-instruments. <bold><italic>Conclusion</italic></bold>: The use of 5-mm instruments was advantageous in renal and pelvic sites. The benefits in upper abdominal surgery need further evaluation, particularly in patients weighing &lt;10 kg. Smaller sized instruments with high endowrist dexterity would<abstract> <title>Abstract</title> <p> <bold> <italic>Purpose:</italic> </bold> The study was designed to assess the utility and controversies surrounding the usage of 5-mm instruments in paediatric robotic surgery. Adequate, delicate instruments for surgery in very narrow spaces are still lacking. <bold><italic>Material and methods</italic></bold>: Thirty children underwent elective abdominal robotic surgery. Working sites, assembly and operative time, hospital stay, advantages, complications and shortcomings are reported. <bold><italic>Results</italic></bold>: Interventions were performed in the following anatomical sites: 11 upper abdominal, nine pelvic, ten renal procedures. The majority of procedures required two operative trocars. A 2–3 mm accessory port was necessary for operations in the renal area and upper abdomen. The ports had to be placed at least 3 cm from the costal margins and superior iliac spines and at an angle of at least 130° with respect to the camera trocar. This configuration allowed intra-corporal knotting, vessel ligation and dissection with instruments in the inverted position. Operative times and hospital stays were similar to those reported for 8 mm-instruments. <bold><italic>Conclusion</italic></bold>: The use of 5-mm instruments was advantageous in renal and pelvic sites. The benefits in upper abdominal surgery need further evaluation, particularly in patients weighing &lt;10 kg. Smaller sized instruments with high endowrist dexterity would resolve the problems encountered in paediatric robotic-assisted surgery using 5-mm instruments.</p> </abstract> … (more)
- Is Part Of:
- Minimally invasive therapy & allied technologies. Volume 24:Issue 3(2015)
- Journal:
- Minimally invasive therapy & allied technologies
- Issue:
- Volume 24:Issue 3(2015)
- Issue Display:
- Volume 24, Issue 3 (2015)
- Year:
- 2015
- Volume:
- 24
- Issue:
- 3
- Issue Sort Value:
- 2015-0024-0003-0000
- Page Start:
- 148
- Page End:
- 153
- Publication Date:
- 2014-06
- Subjects:
- Endoscopy -- Periodicals
Interventional radiology -- Periodicals
Endoscopic surgery -- Periodicals
617.05 - Journal URLs:
- http://informahealthcare.com/loi/mit ↗
http://informahealthcare.com ↗ - DOI:
- 10.3109/13645706.2014.975135 ↗
- Languages:
- English
- ISSNs:
- 1364-5706
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5797.714000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 4162.xml