Test–retest reliability of four sensory measures in people with multiple sclerosis. Issue 1 (March 2015)
- Record Type:
- Journal Article
- Title:
- Test–retest reliability of four sensory measures in people with multiple sclerosis. Issue 1 (March 2015)
- Main Title:
- Test–retest reliability of four sensory measures in people with multiple sclerosis
- Authors:
- Uszynski, Marcin
Purtill, Helen
Coote, Susan - Abstract:
- <abstract> <title> <x xml:space="preserve">Abstract</x> </title> <sec> <p>This study investigated the test–retest reliability of the Neurothesiometer (NT), Verbal Analogue Scale for sensation (VAS), Erasmus modifications to the Nottingham Sensory assessment (EmNSA) and Semmes–Weinstein monofilaments (SWM) in people with multiple sclerosis (MS). A random sample of 34 people with MS who walked with or without an assistive device participated in this study. Participants were tested twice with the NT, VAS, EmNSA and SWM, 1 week apart. For categorical data, Cohen's kappa (<italic>Κ</italic>), percentage agreement (<italic>P</italic><sub>0</sub>) and prevalence-adjusted bias-adjusted kappa (PABAK) were used. For continuous data, intraclass correlation coefficients [ICC (3, 1)] with 95% confidence intervals (95% CI), Bland–Altman plots and standard error of measurement (SEM) were calculated. The ICC values for NT were good, being the highest for the plantar aspect of the heel (ICC=0.92, 95% CI 0.85–0.96, SEM=4.24). Good ICC values were obtained for VAS questions on numbness, pins and needles and temperature and were supported by low SEM. <italic>Κ</italic> values for SWM were poor, ranging from 0.11 to 0.46 for the upper limb and 0.12 to 0.29 for the lower limb. Findings for EmNSA need further verification because of a possible ceiling effect in this test. The NT and VAS assessments for sensation had good test–retest reliability and should be considered for measuring changes in<abstract> <title> <x xml:space="preserve">Abstract</x> </title> <sec> <p>This study investigated the test–retest reliability of the Neurothesiometer (NT), Verbal Analogue Scale for sensation (VAS), Erasmus modifications to the Nottingham Sensory assessment (EmNSA) and Semmes–Weinstein monofilaments (SWM) in people with multiple sclerosis (MS). A random sample of 34 people with MS who walked with or without an assistive device participated in this study. Participants were tested twice with the NT, VAS, EmNSA and SWM, 1 week apart. For categorical data, Cohen's kappa (<italic>Κ</italic>), percentage agreement (<italic>P</italic><sub>0</sub>) and prevalence-adjusted bias-adjusted kappa (PABAK) were used. For continuous data, intraclass correlation coefficients [ICC (3, 1)] with 95% confidence intervals (95% CI), Bland–Altman plots and standard error of measurement (SEM) were calculated. The ICC values for NT were good, being the highest for the plantar aspect of the heel (ICC=0.92, 95% CI 0.85–0.96, SEM=4.24). Good ICC values were obtained for VAS questions on numbness, pins and needles and temperature and were supported by low SEM. <italic>Κ</italic> values for SWM were poor, ranging from 0.11 to 0.46 for the upper limb and 0.12 to 0.29 for the lower limb. Findings for EmNSA need further verification because of a possible ceiling effect in this test. The NT and VAS assessments for sensation had good test–retest reliability and should be considered for measuring changes in sensation in ambulatory people with MS. In contrast, findings from EmNSA and SWM revealed either questionable or poor test–retest reliability, suggesting that these two measures need further investigation.</p> </sec> </abstract> … (more)
- Is Part Of:
- International journal of rehabilitation research. Volume 38:Issue 1(2015:Mar.)
- Journal:
- International journal of rehabilitation research
- Issue:
- Volume 38:Issue 1(2015:Mar.)
- Issue Display:
- Volume 38, Issue 1 (2015)
- Year:
- 2015
- Volume:
- 38
- Issue:
- 1
- Issue Sort Value:
- 2015-0038-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2015-03
- Subjects:
- Rehabilitation -- Periodicals
Rehabilitation -- periodicals
Disabled Persons -- periodicals
617.03 - Journal URLs:
- http://gateway.tx.ovid.com/gw1/ovidweb.cgi ↗
http://journals.lww.com/intjrehabilres/pages/default.aspx ↗
http://ovidsp.ovid.com/ovidweb.cgi?T=JS&NEWS=n&CSC=Y&PAGE=toc&D=yrovft&AN=00004356-000000000-00000 ↗
http://journals.lww.com/pages/default.aspx ↗
http://firstsearch.oclc.org ↗
http://www.lww.com/Product/0342-5282 ↗ - DOI:
- 10.1097/MRR.0000000000000098 ↗
- Languages:
- English
- ISSNs:
- 0342-5282
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4542.526000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 3603.xml