A comparison between 11C-methionine PET/CT and MIBI SPECT/CT for localization of parathyroid adenomas/hyperplasia. Issue 1 (January 2015)
- Record Type:
- Journal Article
- Title:
- A comparison between 11C-methionine PET/CT and MIBI SPECT/CT for localization of parathyroid adenomas/hyperplasia. Issue 1 (January 2015)
- Main Title:
- A comparison between 11C-methionine PET/CT and MIBI SPECT/CT for localization of parathyroid adenomas/hyperplasia
- Authors:
- Hayakawa, Nobuyuki
Nakamoto, Yuji
Kurihara, Kensuke
Yasoda, Akihiro
Kanamoto, Naotetsu
Miura, Masako
Inagaki, Nobuya
Togashi, Kaori - Abstract:
- <abstract> <title> <x xml:space="preserve">Abstract</x> </title> <sec> <title>Objective</title> <p>The purpose of this study was to compare the sensitivity of single-photon emission computed tomography/computed tomography (SPECT/CT) using <sup>99m</sup>Tc-sestamibi (MIBI) with that of PET/CT using <sup>11</sup>C-methionine (MET) for localization of parathyroid adenomas/hyperplasia in primary hyperparathyroidism.</p> </sec> <sec> <title>Materials and methods</title> <p>Twenty-three patients with primary hyperparathyroidism were analyzed. Fifteen patients underwent surgery, and the remaining eight did not, but these patients were clinically diagnosed as having primary hyperparathyroidism. Patients underwent both MET PET/CT and MIBI SPECT/CT scanning. The sensitivities of both modalities were evaluated on a per-patient basis, and on a per-lesion basis for parathyroid lesions detected by surgery. The size of the parathyroid adenoma/hyperplasia and serum intact parathyroid hormone levels were compared with the results of each of the two modalities.</p> </sec> <sec> <title>Results</title> <p>Per-patient sensitivities of MET PET/CT and MIBI SPECT/CT were 65 and 61%, respectively. Per-lesion sensitivities of MET PET/CT and MIBI SPECT/CT were 91 and 73% for histologically confirmed adenomas and 30 and 30% for hyperplastic glands, respectively. No significant differences were observed between the two modalities. The size of uptake-positive lesions was significantly larger than that of<abstract> <title> <x xml:space="preserve">Abstract</x> </title> <sec> <title>Objective</title> <p>The purpose of this study was to compare the sensitivity of single-photon emission computed tomography/computed tomography (SPECT/CT) using <sup>99m</sup>Tc-sestamibi (MIBI) with that of PET/CT using <sup>11</sup>C-methionine (MET) for localization of parathyroid adenomas/hyperplasia in primary hyperparathyroidism.</p> </sec> <sec> <title>Materials and methods</title> <p>Twenty-three patients with primary hyperparathyroidism were analyzed. Fifteen patients underwent surgery, and the remaining eight did not, but these patients were clinically diagnosed as having primary hyperparathyroidism. Patients underwent both MET PET/CT and MIBI SPECT/CT scanning. The sensitivities of both modalities were evaluated on a per-patient basis, and on a per-lesion basis for parathyroid lesions detected by surgery. The size of the parathyroid adenoma/hyperplasia and serum intact parathyroid hormone levels were compared with the results of each of the two modalities.</p> </sec> <sec> <title>Results</title> <p>Per-patient sensitivities of MET PET/CT and MIBI SPECT/CT were 65 and 61%, respectively. Per-lesion sensitivities of MET PET/CT and MIBI SPECT/CT were 91 and 73% for histologically confirmed adenomas and 30 and 30% for hyperplastic glands, respectively. No significant differences were observed between the two modalities. The size of uptake-positive lesions was significantly larger than that of uptake-negative lesions in both modalities. Intact parathyroid hormone levels showed no significant difference between uptake-positive and uptake-negative patients in both modalities.</p> </sec> <sec> <title>Conclusion</title> <p>The sensitivities of MET PET/CT and MIBI SPECT/CT were comparable. MET PET/CT has a complementary role in localizing parathyroid adenomas/hyperplasia when MIBI SPECT/CT is inconclusive.</p> </sec> </abstract> … (more)
- Is Part Of:
- Nuclear medicine communications. Volume 36:Issue 1(2015:Jan.)
- Journal:
- Nuclear medicine communications
- Issue:
- Volume 36:Issue 1(2015:Jan.)
- Issue Display:
- Volume 36, Issue 1 (2015)
- Year:
- 2015
- Volume:
- 36
- Issue:
- 1
- Issue Sort Value:
- 2015-0036-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2015-01
- Subjects:
- Nuclear medicine -- Periodicals
616.07575 - Journal URLs:
- http://journals.lww.com/nuclearmedicinecomm/pages/default.aspx ↗
http://journals.lww.com/pages/default.aspx ↗
http://www.lww.com/Product/0143-3636 ↗ - DOI:
- 10.1097/MNM.0000000000000216 ↗
- Languages:
- English
- ISSNs:
- 0143-3636
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6180.923000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 3752.xml