Breast DWI at 3 T: influence of the fat-suppression technique on image quality and diagnostic performance. Issue 3 (March 2015)
- Record Type:
- Journal Article
- Title:
- Breast DWI at 3 T: influence of the fat-suppression technique on image quality and diagnostic performance. Issue 3 (March 2015)
- Main Title:
- Breast DWI at 3 T: influence of the fat-suppression technique on image quality and diagnostic performance
- Authors:
- Nogueira, Luisa
Brandão, Sofia
Nunes, Rita G.
Ferreira, Hugo Alexandre
Loureiro, Joana
Ramos, Isabel - Abstract:
- <abstract xml:lang="en" abstract-type="author" id="abs0010"> <title> <x xml:space="preserve">Abstract</x> </title> <sec> <title id="sectitle0010">Aim</title> <p id="abspara0010">To evaluate two fat-suppression techniques: short tau inversion recovery (STIR) and spectral adiabatic inversion recovery (SPAIR) regarding image quality and diagnostic performance in diffusion-weighted imaging (DWI) of breast lesions at 3 T.</p> </sec> <sec> <title id="sectitle0015">Materials and methods</title> <p id="abspara0015">Ninety-two women (mean age 48 ± 12.1 years; range 21–78 years) underwent breast MRI. Two DWI pulse sequences, with b-values (50 and 1000 s/mm<sup>2</sup>) were performed with STIR and SPAIR. The signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), suppression homogeneity, and apparent diffusion coefficient (ADC) values were quantitatively assessed for each technique. Values were compared between techniques and lesion type. Receiver operating characteristics (ROC) analysis was used to evaluate lesion discrimination.</p> </sec> <sec> <title id="sectitle0020">Results</title> <p id="abspara0020">One hundred and fourteen lesions were analysed (40 benign and 74 malignant). SNR and CNR were significantly higher for DWI-SPAIR; fat-suppression uniformity was better for DWI-STIR (<italic>p</italic> &lt; 1 × 10<sup>−4</sup>). ADC values for benign and malignant lesions and normal tissue were 1.92 × 10<sup>−3</sup>, 1.18 × 10<sup>−3</sup>,<abstract xml:lang="en" abstract-type="author" id="abs0010"> <title> <x xml:space="preserve">Abstract</x> </title> <sec> <title id="sectitle0010">Aim</title> <p id="abspara0010">To evaluate two fat-suppression techniques: short tau inversion recovery (STIR) and spectral adiabatic inversion recovery (SPAIR) regarding image quality and diagnostic performance in diffusion-weighted imaging (DWI) of breast lesions at 3 T.</p> </sec> <sec> <title id="sectitle0015">Materials and methods</title> <p id="abspara0015">Ninety-two women (mean age 48 ± 12.1 years; range 21–78 years) underwent breast MRI. Two DWI pulse sequences, with b-values (50 and 1000 s/mm<sup>2</sup>) were performed with STIR and SPAIR. The signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), suppression homogeneity, and apparent diffusion coefficient (ADC) values were quantitatively assessed for each technique. Values were compared between techniques and lesion type. Receiver operating characteristics (ROC) analysis was used to evaluate lesion discrimination.</p> </sec> <sec> <title id="sectitle0020">Results</title> <p id="abspara0020">One hundred and fourteen lesions were analysed (40 benign and 74 malignant). SNR and CNR were significantly higher for DWI-SPAIR; fat-suppression uniformity was better for DWI-STIR (<italic>p</italic> &lt; 1 × 10<sup>−4</sup>). ADC values for benign and malignant lesions and normal tissue were 1.92 × 10<sup>−3</sup>, 1.18 × 10<sup>−3</sup>, 1.86 × 10<sup>−3</sup> s/mm<sup>2</sup> for DWI-STIR and 1.80 × 10<sup>−3</sup>, 1.11 × 10<sup>−3</sup>, 1.79 × 10<sup>−3</sup> s/mm<sup>2</sup> for SPAIR, respectively. Comparison between fat-suppression techniques showed significant differences in mean ADC values for benign (<italic>p</italic> = 0.013) and malignant lesions (<italic>p</italic> = 0.001). DWI-STIR and -SPAIR ADC cut-offs were 1.42 × 10<sup>−3</sup> and 1.46 × 10<sup>−3</sup> s/mm<sup>2</sup>, respectively. Diagnostic performance for DWI-STIR versus SPAIR was: accuracy (81.6 versus 83.3%), area under curve (87.7 versus 89.2%), sensitivity (79.7 versus 85.1%), and specificity (85 versus 80%). Positive predictive value was similar.</p> </sec> <sec> <title id="sectitle0025">Conclusion</title> <p id="abspara0025">The fat-saturation technique used in the present study may influence image quality and ADC quantification. Nevertheless, STIR and SPAIR techniques showed similar diagnostic performances, and therefore, both are suitable for use in clinical practice.</p> </sec> </abstract> … (more)
- Is Part Of:
- Clinical radiology. Volume 70:Issue 3(2015)
- Journal:
- Clinical radiology
- Issue:
- Volume 70:Issue 3(2015)
- Issue Display:
- Volume 70, Issue 3 (2015)
- Year:
- 2015
- Volume:
- 70
- Issue:
- 3
- Issue Sort Value:
- 2015-0070-0003-0000
- Page Start:
- 286
- Page End:
- 294
- Publication Date:
- 2015-03
- Subjects:
- Medical radiology -- Periodicals
Radiotherapy -- Periodicals
Radiotherapy -- Periodicals
Radiology -- Periodicals
Societies, Medical -- Periodicals
Medical radiology
Radiotherapy
Electronic journals
Periodicals
616.0757 - Journal URLs:
- http://www.sciencedirect.com/science/journal/00099260 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.crad.2014.11.012 ↗
- Languages:
- English
- ISSNs:
- 0009-9260
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.350000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 3914.xml