A comparative study on complete and implant retained denture treatments – A biomechanics perspective. Issue 3 (5th February 2015)
- Record Type:
- Journal Article
- Title:
- A comparative study on complete and implant retained denture treatments – A biomechanics perspective. Issue 3 (5th February 2015)
- Main Title:
- A comparative study on complete and implant retained denture treatments – A biomechanics perspective
- Authors:
- Chen, Junning
Ahmad, Rohana
Suenaga, Hanako
Li, Wei
Swain, Michael
Li, Qing - Abstract:
- <abstract abstract-type="author" id="ab0005"> <title id="sect0005">Abstract</title> <sec> <p id="sp0045">Although implant-retained overdenture allows edentulous patients to take higher occlusal forces than the conventional complete dentures, the biomechanical influences have not been explored yet. Clinically, there is limited knowledge and means for predicting localized bone remodelling after denture treatment with and without implant support. By using finite element (FE) analysis, this article provides an <italic>in-silico</italic> approach to exploring the treatment effects on the oral mucosa and potential resorption of residual ridge under three different denture configurations in a patient-specific manner. Based on cone beam computerized tomography (CBCT) scans, a 3D heterogeneous FE model was created; and the supportive tissue, mucosa, was characterized as a hyperelastic material. A measured occlusal load (63N) was applied onto three virtual models, namely complete denture, two and four implant-retained overdentures. Clinically, the bone resorption was measured after one year in the two implant-retained overdenture treatment. Despite the improved stability and enhanced masticatory function, the implant-retained overdentures demonstrated higher hydrostatic stress in mucosa (43.6 kPa and 39.9 kPa for two and four implants) at the posterior ends of the mandible due to the cantilever effect, than the complete denture (33.4 kPa). Hydrostatic pressure in the mucosa signifies<abstract abstract-type="author" id="ab0005"> <title id="sect0005">Abstract</title> <sec> <p id="sp0045">Although implant-retained overdenture allows edentulous patients to take higher occlusal forces than the conventional complete dentures, the biomechanical influences have not been explored yet. Clinically, there is limited knowledge and means for predicting localized bone remodelling after denture treatment with and without implant support. By using finite element (FE) analysis, this article provides an <italic>in-silico</italic> approach to exploring the treatment effects on the oral mucosa and potential resorption of residual ridge under three different denture configurations in a patient-specific manner. Based on cone beam computerized tomography (CBCT) scans, a 3D heterogeneous FE model was created; and the supportive tissue, mucosa, was characterized as a hyperelastic material. A measured occlusal load (63N) was applied onto three virtual models, namely complete denture, two and four implant-retained overdentures. Clinically, the bone resorption was measured after one year in the two implant-retained overdenture treatment. Despite the improved stability and enhanced masticatory function, the implant-retained overdentures demonstrated higher hydrostatic stress in mucosa (43.6 kPa and 39.9 kPa for two and four implants) at the posterior ends of the mandible due to the cantilever effect, than the complete denture (33.4 kPa). Hydrostatic pressure in the mucosa signifies a critical indicator and can be correlated with clinically measured bone resorption, pointing to severer mandibular ridge resorption posteriorly with implant-retained overdentures. This study provides a biomechanical basis for denture treatment planning to improve long-term outcomes with minimal residual ridge resorption.</p> </sec> </abstract> … (more)
- Is Part Of:
- Journal of biomechanics. Volume 48:Issue 3(2015)
- Journal:
- Journal of biomechanics
- Issue:
- Volume 48:Issue 3(2015)
- Issue Display:
- Volume 48, Issue 3 (2015)
- Year:
- 2015
- Volume:
- 48
- Issue:
- 3
- Issue Sort Value:
- 2015-0048-0003-0000
- Page Start:
- 512
- Page End:
- 519
- Publication Date:
- 2015-02-05
- Subjects:
- Animal mechanics -- Periodicals
Biomechanics -- Periodicals
Biomechanics -- Periodicals
Mécanique animale -- Périodiques
Biomécanique -- Périodiques
Electronic journals
571.4305 - Journal URLs:
- http://www.sciencedirect.com/science/journal/00219290 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/00219290 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/00219290 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jbiomech.2014.11.043 ↗
- Languages:
- English
- ISSNs:
- 0021-9290
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4953.600000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 4099.xml