A 6-year study of mammographic compression force: Practitioner variability within and between screening sites. Issue 1 (February 2015)
- Record Type:
- Journal Article
- Title:
- A 6-year study of mammographic compression force: Practitioner variability within and between screening sites. Issue 1 (February 2015)
- Main Title:
- A 6-year study of mammographic compression force: Practitioner variability within and between screening sites
- Authors:
- Mercer, Claire E.
Szczepura, Katy
Kelly, Judith
Millington, Sara R.
Denton, Erika R.E.
Borgen, Rita
Hilton, Beverley
Hogg, Peter - Abstract:
- <abstract xml:lang="en" abstract-type="author" id="abs0010"> <title id="sectitle0010">Abstract</title> <sec> <title id="sectitle0015">Background</title> <p id="abspara0010">The application of compression force in mammography is more heavily influenced by the practitioner rather than the client. This can affect client experience, radiation dose and image quality. This research investigates practitioner compression force variation over a six year screening cycle in three different screening units.</p> </sec> <sec> <title id="sectitle0020">Methods</title> <p id="abspara0015">Data were collected from three consecutive screening events in three breast screening sites. Recorded data included: practitioner code, applied compression force (N), breast thickness (mm), BI-RADS<sup>®</sup> density category. Exclusion criteria included: previous breast surgery, previous/ongoing assessment and breast implants. 975 clients (2925 client visits, 11, 700 mammogram images) met inclusion criteria across three sites. Data analysis assessed practitioner and site variation of compression force and breast thickness.</p> </sec> <sec> <title id="sectitle0025">Results</title> <p id="abspara0020">Practitioners across three breast screening sites behave differently in the application of compression force. Two of the three sites demonstrate variability within themselves though they demonstrated no significant difference in mean, first and third quartile compression force and breast thickness values CC<abstract xml:lang="en" abstract-type="author" id="abs0010"> <title id="sectitle0010">Abstract</title> <sec> <title id="sectitle0015">Background</title> <p id="abspara0010">The application of compression force in mammography is more heavily influenced by the practitioner rather than the client. This can affect client experience, radiation dose and image quality. This research investigates practitioner compression force variation over a six year screening cycle in three different screening units.</p> </sec> <sec> <title id="sectitle0020">Methods</title> <p id="abspara0015">Data were collected from three consecutive screening events in three breast screening sites. Recorded data included: practitioner code, applied compression force (N), breast thickness (mm), BI-RADS<sup>®</sup> density category. Exclusion criteria included: previous breast surgery, previous/ongoing assessment and breast implants. 975 clients (2925 client visits, 11, 700 mammogram images) met inclusion criteria across three sites. Data analysis assessed practitioner and site variation of compression force and breast thickness.</p> </sec> <sec> <title id="sectitle0025">Results</title> <p id="abspara0020">Practitioners across three breast screening sites behave differently in the application of compression force. Two of the three sites demonstrate variability within themselves though they demonstrated no significant difference in mean, first and third quartile compression force and breast thickness values CC (<italic>p</italic> &gt; 0.5), MLO (<italic>p</italic> &gt; 0.1) between themselves. However, in the third site, where mandate dictates a minimum compression force is applied, greater consistency was demonstrated between practitioners and clients; a significant difference in mean, first and third quartile compression force and breast thickness values (<italic>p</italic> &lt; 0.001) was demonstrated between this site and the other two sites.</p> </sec> <sec> <title id="sectitle0030">Conclusion</title> <p id="abspara0025">Variability within these two sites and between the three sites could result in variations. Stabilisation of these variations may have a positive impact on image quality, radiation dose reduction, re-attendance levels and potentially cancer detection. The large variation in compression forces could negatively impact on client experience between the units and within a unit.</p> <p id="abspara0030">Further research is required to establish best practice guidelines for compression force within mammography.</p> </sec> <sec> <title id="sectitle0035">Advances in knowledge</title> <p id="abspara0035">Practitioners vary in the compression forces they apply to clients over sequential screening attendances. Establishing practice guidance with cessation guidelines could help to minimise this problem.</p> </sec> </abstract> … (more)
- Is Part Of:
- Radiography. Volume 21:Issue 1(2015)
- Journal:
- Radiography
- Issue:
- Volume 21:Issue 1(2015)
- Issue Display:
- Volume 21, Issue 1 (2015)
- Year:
- 2015
- Volume:
- 21
- Issue:
- 1
- Issue Sort Value:
- 2015-0021-0001-0000
- Page Start:
- 68
- Page End:
- 73
- Publication Date:
- 2015-02
- Subjects:
- Diagnostic imaging -- Periodicals
Radiotherapy -- Periodicals
Cancer -- Radiotherapy -- Periodicals
Diagnostic Imaging -- Periodicals
Neoplasms -- Periodicals
Radiotherapy -- Periodicals
Imagerie pour le diagnostic -- Périodiques
Radiothérapie -- Périodiques
Cancer -- Radiothérapie -- Périodiques
Electronic journals
616.0757 - Journal URLs:
- http://www.sciencedirect.com/science/journal/10788174 ↗
http://www.radiographyonline.com/ ↗
http://www.harcourt-international.com/journals ↗
http://www.idealibrary.com/links/toc/radi/ ↗
http://www.clinicalkey.com/dura/browse/journalIssue/10788174 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/10788174 ↗
http://www.elsevier.com/journals ↗
http://www.journals.elsevier.com/radiography/ ↗ - DOI:
- 10.1016/j.radi.2014.07.004 ↗
- Languages:
- English
- ISSNs:
- 1078-8174
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7237.001000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 3701.xml