Metrics of Quality Care in Veterans: Correlation Between Primary‐Care Performance Measures and Inappropriate Myocardial Perfusion Imaging. Issue 4 (13th April 2015)
- Record Type:
- Journal Article
- Title:
- Metrics of Quality Care in Veterans: Correlation Between Primary‐Care Performance Measures and Inappropriate Myocardial Perfusion Imaging. Issue 4 (13th April 2015)
- Main Title:
- Metrics of Quality Care in Veterans: Correlation Between Primary‐Care Performance Measures and Inappropriate Myocardial Perfusion Imaging
- Authors:
- Winchester, David E.
Kitchen, Andrew
Brandt, John C.
Dusaj, Raman S.
Virani, Salim S.
Bradley, Steven M.
Shaw, Leslee J.
Beyth, Rebecca J. - Abstract:
- <abstract abstract-type="main" id="clc22388-abs-0001"> <title>ABSTRACT</title> <sec id="clc22388-sec-0001" sec-type="section"> <title>Background</title> <p id="clc22388-para-0001">Approximately 10% to 20% of myocardial perfusion imaging (MPI) tests are inappropriate based on professional‐society recommendations. The correlation between inappropriate MPI and quality care metrics is not known.</p> </sec> <sec id="clc22388-sec-0002" sec-type="section"> <title>Hypothesis</title> <p id="clc22388-para-0002">Inappropriate MPI will be associated with low achievement of quality care metrics.</p> </sec> <sec id="clc22388-sec-0003" sec-type="section"> <title>Methods</title> <p id="clc22388-para-0003">We conducted a retrospective cross‐sectional investigation at a single Veterans Affairs medical center. Myocardial perfusion imaging tests ordered by primary‐care clinicians between December 2010 and July 2011 were assessed for appropriateness (by 2009 criteria). Using documentation of the clinical encounter where MPI was ordered, we determined how often quality care metrics were achieved.</p> </sec> <sec id="clc22388-sec-0004" sec-type="section"> <title>Results</title> <p id="clc22388-para-0004">Among 516 MPI patients, 52 (10.1%) were inappropriate and 464 (89.9%) were not inappropriate (either appropriate or uncertain). Hypertension (82.2%), diabetes mellitus (41.3%), and coronary artery disease (41.1%) were common. Glycated hemoglobin levels were lower in the inappropriate MPI cohort<abstract abstract-type="main" id="clc22388-abs-0001"> <title>ABSTRACT</title> <sec id="clc22388-sec-0001" sec-type="section"> <title>Background</title> <p id="clc22388-para-0001">Approximately 10% to 20% of myocardial perfusion imaging (MPI) tests are inappropriate based on professional‐society recommendations. The correlation between inappropriate MPI and quality care metrics is not known.</p> </sec> <sec id="clc22388-sec-0002" sec-type="section"> <title>Hypothesis</title> <p id="clc22388-para-0002">Inappropriate MPI will be associated with low achievement of quality care metrics.</p> </sec> <sec id="clc22388-sec-0003" sec-type="section"> <title>Methods</title> <p id="clc22388-para-0003">We conducted a retrospective cross‐sectional investigation at a single Veterans Affairs medical center. Myocardial perfusion imaging tests ordered by primary‐care clinicians between December 2010 and July 2011 were assessed for appropriateness (by 2009 criteria). Using documentation of the clinical encounter where MPI was ordered, we determined how often quality care metrics were achieved.</p> </sec> <sec id="clc22388-sec-0004" sec-type="section"> <title>Results</title> <p id="clc22388-para-0004">Among 516 MPI patients, 52 (10.1%) were inappropriate and 464 (89.9%) were not inappropriate (either appropriate or uncertain). Hypertension (82.2%), diabetes mellitus (41.3%), and coronary artery disease (41.1%) were common. Glycated hemoglobin levels were lower in the inappropriate MPI cohort (6.6% vs 7.5%; <italic>P</italic> = 0.04). No difference was observed in the proportion with goal hemoglobin (62.5% vs 46.3% for appropriate/uncertain; <italic>P</italic> = 0.258). Systolic blood pressure was not different (132 mm Hg vs 135 mm Hg; <italic>P</italic> = 0.34). Achievement of several other categorical quality metrics was low in both cohorts and no differences were observed. More than 90% of clinicians documented a plan to achieve most metrics.</p> </sec> <sec id="clc22388-sec-0005" sec-type="section"> <title>Conclusions</title> <p id="clc22388-para-0005">Inappropriate MPI is not associated with performance on metrics of quality care. If an association exists, it may be between inappropriate MPI and overly aggressive care. Most clinicians document a plan of care to address failure of quality metrics, suggesting awareness of the problem.</p> </sec> </abstract> … (more)
- Is Part Of:
- Clinical cardiology. Volume 38:Issue 4(2015:Apr.)
- Journal:
- Clinical cardiology
- Issue:
- Volume 38:Issue 4(2015:Apr.)
- Issue Display:
- Volume 38, Issue 4 (2015)
- Year:
- 2015
- Volume:
- 38
- Issue:
- 4
- Issue Sort Value:
- 2015-0038-0004-0000
- Page Start:
- 195
- Page End:
- 199
- Publication Date:
- 2015-04-13
- Subjects:
- Cardiology -- Periodicals
616.12005 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1932-8737/issues ↗
http://www3.interscience.wiley.com/journal/113412417/home ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/clc.22388 ↗
- Languages:
- English
- ISSNs:
- 0160-9289
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.265000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 4125.xml